background image

2 of 4

QUICK START GUIDE:

 Edge

www.symetrix.co 

+1.425.778.7728

Software Installation

Composer is the software that provides real-time set-up and 
control of Edge from a Win dows PC environment.
Use the following procedure to install Composer on your 
computer.

From the Symetrix web site (http://www.symetrix.co):

1. Download the Composer software installer from the 

Symetrix web site.

2. Double-click on the file you just downloaded and follow 

the on screen directions to install.

After installing the software, refer to the Help File for full 
connection and configuration information.

Network Setup

About DHCP

Edge boots with DHCP enabled by default. This means 
that as soon as you connect it to a network, it will look for 
a DHCP server in order to obtain an IP address. If a DHCP 
server is present, Edge will obtain an IP address from it. This 
process may take several minutes. With your PC attached to 
the same network, and thus getting its IP address from the 
same DHCP server, all will be ready to go.
If your network does not have a DHCP server, Edge will not 
be able to obtain an IP address. While waiting, Edge will 
default to a private IP address in the range of 169.254.x.x 
where x.x is the last four alphanumeric characters of Edge’s 
MAC address (MAC address hex value is converted to 
decimal for IP address). Edge’s MAC address can be found 
on a sticker on the bottom of hardware.
When there is no DHCP server present to assign IP 
addresses to either Edge or your PC, you may need to 
configure your PC with a static IP in the range of 169.254.x.x 
with a Subnet Mask of 255.255.0.0 in order to communicate 
with Edge in a direct connect mode. However, if your PC 
is using the default network settings, it should also have 
automatically self-assigned a similar private IP address in the 
range of 169.254.x.x, and if this is the case, you should be 
able to connect to Edge directly.
Even if the PC’s default settings have been changed, 
Edge will try to establish communications by setting up 
appropriate routing table entries to reach devices with 
169.254.x.x addresses.

Connecting to Edge from a host computer on the 
same LAN

Both Edge and the host computer require the following 3 
items:
1. IP Address - The unique address of a node on a network.
2. Subnet Mask - Configuration that defines which IP 

Addresses are included in a particular subnet.

3. Default Gateway (optional) - The IP address of a device 

that routes traffic from one subnet to another. (This is only 
needed when the PC and Edge are on different subnets).

If you are putting Edge on an existing network, a network 
administrator will be able to provide the above information or 
it may have been provided automatically by a DHCP server. 
For security reasons, it is not recommended to put Edge 
directly on the Internet. If you do, a network administrator 
or your Internet Service Provider can provide the above 
information.
If you are on your own private network, directly or indirectly 
connected to Edge, you may allow Edge to choose an 
automatic IP address or you may choose to assign it a static 
IP address. If you are building your own separate network 
with static assigned addresses, you may consider using an 
IP Address from one of the ”Private-Use” networks noted in 
RFC-1918:
1. 172.16.0.0/12 = IP Addresses 172.16.0.1 through 

172.31.254.254 and a Subnet Mask of 255.240.0.0

2. 192.168.0.0/16 = IP Addresses 192.168.0.1 through 

192.168.254.254 and a Subnet Mask of 255.255.0.0

3. 10.0.0.0/8 = IP Addresses 10.0.0.1 through 

10.254.254.254 and a Subnet Mask of 255.255.0.0

Connecting to Edge through a Firewall/VPN

We have successfully tested control of Edge through a 
firewall and VPN, but are unable to guarantee performance 
of these types of connections at this time. Configuration 
instructions are specific to each firewall and VPN, 
so specifics are not available. Additionally, wireless 
communications are also not guaranteed, though have also 
been successfully tested.

Содержание Edge

Страница 1: ...into your outlet consult an electrician for replacement of the obsolete outlet BL Ensure proper ESD control and grounding when handling exposed I O terminals BM Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus BN Only use attachments accessories specified by the manufacturer BO Use only with the ca...

Страница 2: ...ct to Edge directly Even if the PC s default settings have been changed Edge will try to establish communications by setting up appropriate routing table entries to reach devices with 169 254 x x addresses Connecting to Edge from a host computer on the same LAN Both Edge and the host computer require the following 3 items 1 IP Address The unique address of a node on a network 2 Subnet Mask Configu...

Страница 3: ...sk and Gateway Click OK when finished Now back in the locate hardware dialog ensure the Edge device is selected and click Select Hardware Unit to use this Edge hardware in your Site File Close the Locate Hardware dialog IP Configuration with the Front Panel Edge IP information can also be edited from the front panel Edge s front panel interface starts up in System Mode out of the box Press LEFT or...

Страница 4: ...ratches and dents unless failure has occurred due to a defect in materials or workmanship within the warranty period 7 Conditions caused by normal wear and tear or otherwise due to the normal aging of Symetrix products 8 Damage caused by use with another product 9 Product on which any serial number has been removed altered or defaced 10 Product that isn t sold by an authorized Symetrix Dealer or D...