3/26
User’s Guide
6200 Digital
Voice Processor
To download the latest version of 6200 Designer, a Windows GUI
application interface for the 6200, go to: www.airtoolsaudio.com
TM
Symetrix
Engineered by
Front Panel
Item
Description
What It Does
BYPASS
Momentary button
Toggles DSP bypass state on top level menus. Toggles DSP module bypass state
on individual DSP module menus.
PREV / EXIT
Momentary button
Moves to the previous menu item or exits to the top of the menu tree.
NEXT / ENTER
Momentary button
Moves to the next menu item or enters a menu tree.
HOME
Momentary button
Returns to the “HOME” top-level menu.
ADJUST
Continuous rotary encoder
Selects the menu to enter or adjusts the currently selected parameter or menu item.
DISPLAY
Monochrome
Displays status, menu or configuration information.
LOAD 1 / SAVE 1
Momentary button
Loads or saves a program for channel 1.
LOAD 2 / SAVE 2
Momentary button
Loads or saves a program for channel 2.
USB
Female “B” USB 1.1 port
Optional connection to a Windows™ PC for 6200 Designer GUI control.
Rear Panel
Item
Description
What It Does
POWER INPUT
IEC 3 prong jack
Accepts power from detachable IEC power cable (100-240 VAC, 50-60 Hz, 60
Watts max). Connect only to a grounded power outlet.
TC89/TC90 TIME CODE IN Female BNC
Accepts (ESE) TC89 or TC90 time code to drive the real-time clock and Event
Manager. Format and presence is automatically detected.
PROGRAM CONTROL
Male DB9
Simple program recall interface.
RS-232
Female DB9
Optional serial communications interface for 6200 Designer on the host PC.
ETHERNET (10 Base T)
RJ-45
Optional Ethernet communications interface for 6200 Designer on the host PC.
RS-485
Euroblock
Optional long distance serial communications interface for 6200 Designer on the host
PC. Third party 232/422/485 converter products may be required to utilize this port.
REMOTE BYPASS
Euroblock
Allows remote software (DSP) bypass or output muting (output disconnect via
relays) with simple contact closures.
ANALOG CONTROL
Euroblocks
Allows real-time control of up to two parameters per port using standard 10k Ohm
INPUT 1 and 2
linear potentiometers.
MIDI/RC-1 IN
7 pin DIN
Accepts MIDI program change messages to recall programs for channels 1 and 2.
Can also be used with the AirTools RC-1 remote directly. The RC-1 can also be
powered from this port.
HOMERLINK
RJ-45
Transmits 4 AES-3 mono channels and receives 2 AES-3 mono channels over
standard CAT-5. Used for AES digital input, to sync to an external AES clock
source or to integrate with the AirTools Studio Matrix system.
AES OUT 1 and 2
Male XLR
AES-3 digital output - software selectable to carry Channel 1/2, 1/1, 2/1 or 2/2
information.
ANALOG OUT
Male XLR
2 x analog line level audio outputs with software adjustable output level.
ANALOG IN
Female XLR-1/4” combo
2 x analog mic/line level audio inputs with individually software selectable coarse
gain and fine trim.
����������������������������
�����
��������
�������
�����������
�������
�������������
���������������������
���������������������������������������������������
������������������������������������������
�������������������������������������������������
���������������������������������������������
���������
����
����
��
��������
���������
���������
��
������
�������
�������
������
������
������
������
�������
�������
���������
���������
����������
���������
������
������
������
������
������������
���������������
�
�
�
�
������
�������
�
�
��
��
���� ���
���� ���
Front Panel, Rear Panel
Содержание airTools 6200
Страница 32: ......