background image

QUESTIONS? 

Ask the experts at POSMicro.com.

  

1.800.241.6264

   Live Chat Now

   [email protected]

Monday - Friday 6 AM to 5 PM Pacific 

Time

BULk DISCOUNTS

FREE SHIPPING*

SE HaBLa 

ESpa

ñ

OL

*Free ground shipping to the continental USa on orders over $100.

For Help Call 

1.800.241.6264

Motorola Phaser P460
Manual

More information available at  

POSMicro.com

Содержание Phaser P460

Страница 1: ...support POSMicro com Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Espa ol Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264...

Страница 2: ...Phaser Series Scanner Product Reference Guide About This Manual Table Of Contents Index Copyright...

Страница 3: ...rk from a licensed program or use a licensed program in a network without written permission from Symbol The user agrees to maintain Symbol s copyright notice on the licensed programs delivered hereun...

Страница 4: ...attery 1 1 The Cradle 1 2 Chapter 2 Set Up Introduction 2 1 Unpacking 2 1 Cables 2 1 Installing the Cable on the Scanner 2 1 Disconnecting Cables 2 3 Setting Up the Cradle 2 3 Scanner Power Options 2...

Страница 5: ...you follow the operating instructions 3 14 The scanner emits transmit errors error beeps after decode 3 14 Programming the System 3 14 Chapter 4 Maintenance And Specifications Introduction 4 1 Mainten...

Страница 6: ...ecode UPC EAN Supplementals 5 29 Decode UPC EAN Supplemental Redundancy 5 30 Transmit UPC A UPC E UPC E1 Check Digit 5 31 UPC A Preamble 5 32 UPC E Preamble 5 33 UPC E1 Preamble 5 34 Convert UPC E to...

Страница 7: ...Codabar 5 65 CLSI Editing 5 67 NOTIS Editing 5 68 Enable Disable MSI Plessey 5 69 Set Lengths for MSI Plessey 5 70 MSI Plessey Check Digits 5 72 Transmit MSI Plessey Check Digit 5 73 MSI Plessey Check...

Страница 8: ...er scanner t Chapter 3 Operation explains how to operate the Phaser scanner t Chapter 4 Maintenance And Specifications talks about the maintenance and the specifications of the Phaser scanner and the...

Страница 9: ...your bar code symbols at hand Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem If the equipment is found to be work...

Страница 10: ...653 5350 Symbol Technologies Canada Inc 2540 Matheson Boulevard East Mississauga Ontario Canada L4W 422 905 629 7226 International Asia Pacific Symbol Technologies International Symbol Place Winnersh...

Страница 11: ...r 2000 compliant There are two versions available t P 460 the retail version t P 360 the industrial version Unless otherwise noted the term Phaser refers to both versions of the scanner The Phaser suc...

Страница 12: ...ansmits that data to the host device through an attached cable It also acts as a holder for the scanner The cradle also provides power for charging the scanner s battery in the scanner The cradle has...

Страница 13: ...ion Symbol Support Center on page vii KEEP THE PACKING It is the approved shipping container and should be used if you ever need to return your equipment for servicing Cables The following cables are...

Страница 14: ...ttom of the Phaser handle Figure 2 1 Connecting the Cable to the Phaser 3 Turn the cable twist lock 1 8 turn clockwise to seat it Figure 2 2 Locking the Cable to the Phaser 4 Gently pull the cable to...

Страница 15: ...e host computer COM2 is used for daisy chaining multiple base stations together and the Power port supplies power to the cradle Figure 2 1 Ports on the Cradle 1 Connect an appropriate power supply to...

Страница 16: ...the nose of the scanner and tip of the handle seat into the receptacles Figure 2 3 Placing the Scanner into the Cradle 4 Check the charge status indicator light See Table 4 1 on page 4 3 5 The batter...

Страница 17: ...n A new battery p n 50 14000 079 can be obtained from Symbol Technologies See your Symbol representative for more information Connecting to a Host With some host types the Phaser is unable to answer h...

Страница 18: ...4 Connect the power supply into an AC receptacle Using A Synapse Cable with the Cradle 1 Connect the Synapse Adapter cable to COM1 in the cradle 2 Connect the Adapter cable to the Synapse Interface c...

Страница 19: ...apter cable s flying power lead to the receptacle in the Synapse Interface cable refer to Figure 2 4 4 Plug the Synapse Interface cable into the host device 5 Connect an appropriate power supply to th...

Страница 20: ...trates most of the operations of the Phaser including uploading downloading scanning and keyboard entry in both batch and POS modes of operation Your MCL application may be different than what is desc...

Страница 21: ...matically and after a brief 3 second delay the screen clears to accept the next entry However data entry may proceed before the 3 second pause Keyed bar codes must be completed with the ENTER key Afte...

Страница 22: ...do so or if the upload fails for any reason the following screen appears Upload Failed Retry EN Y BK N Figure 3 6 Data Upload Failed Screen The upload may seem to pause before commencing On a cable t...

Страница 23: ...R key To enter a quantity press the key prior to scanning or keying any bar code data Once you press the key the following screen appears QTY _____ Figure 3 10 POS Quantity Screen Key in a quantity fo...

Страница 24: ...directly for advanced users who are already familiar with the options Under each menu item is a sub menu for more options 0 System Setup 0 Set Date 1 Set Time 2 Set Contrast 9 Back To Main 1 App Contr...

Страница 25: ...ed for 24 hours the user loses the real time clock information If the scanner is attached to a cable and there is no battery in the scanner when the cable is removed from the scanner the real time clo...

Страница 26: ...rams functions Scan Params Puts the scanner in a mode where parameter bar codes may be scanned Parameter bar code scanning is disabled at all other times Set Default Params Restores the default parame...

Страница 27: ...the available selections until the desired file is displayed Press ENTER and a confirmation screen appears Erase File X EN Y BK N Figure 3 14 File Erasure Confirmation Press EN to erase the file press...

Страница 28: ...g and communications parameters If you need assistance contact your local supplier or Symbol Support Center 1 If you are using the scanner in corded mode make sure all cable connections are secure Oth...

Страница 29: ...scanner directly over the bar code Laser light reflecting directly back into the scanner from the bar code is known as specular reflection This strong light can blind the scanner and make decoding di...

Страница 30: ...m 15 in 38 1 cm 20 in 50 8 cm 25 in 63 5 cm 30 in 76 2 cm 35 in 88 9 cm 40 in 101 6 cm 45 in 114 3 cm Distance From Front Of Scanner 15 6 in 39 6 cm 15 6 in 39 6 cm 10 in 25 4 cm 10 in 25 4 cm 5 in 12...

Страница 31: ...and a high pitched key click after a second or so to let you know that the entry was accepted You can go from one key to another before hearing the high key click i e from the a to the d but you must...

Страница 32: ...3 13 Operation Figure 3 18 Phaser Keypad...

Страница 33: ...hin the proper scanning range t Reboot the scanner hold down the ENTER key for about 10 20 seconds and try scanning again The scanner emits transmit errors error beeps after decode You Should t Check...

Страница 34: ...ray water or other cleaning liquids directly into the scanner window t If the contacts between the scanner and cradle become dirty clean them with either a pencil eraser or a cotton swab dampened with...

Страница 35: ...tment Cover 3 Slide the battery towards the bottom of the scanner 4 Pull the bottom of the battery out and away from the scanner Figure 4 2 Pulling the Battery Out Replacing the Battery 1 Seat the bat...

Страница 36: ...ccessory is the IntelliStand which permits hands free operation of the Phaser scanner It permits the Phaser to scan continuously and automatically read a bar code when one is presented in front of the...

Страница 37: ...ssion of decoded information depends on the capabilities of the attached terminal Scanner Beeper Operation User selectable Enabled Disabled Scan Repetition Rate 36 5 scans sec bidirectional Roll Skew...

Страница 38: ...Dimensions Height 7 0 in 17 8 cm Width 9 2 in 13 5 cm Depth 3 5 in 9 8 cm Laser Classifications CDRH Class II IEC Class 1 IEC 825 Class 2 Table 4 3 Pin outs Pin Phaserlink Cradle 1 BREQ 2 VCC Out 3 Gr...

Страница 39: ...not properly configured Check option settings 5 Beeps low tone Convert or format error Hi hi hi lo tone RS 232 receive error 4 Beeps short hi Low battery Parameter Menu Scanning Short high tone Corre...

Страница 40: ...e recalled by scanning the bar code in the section Set Default Parameter on page 5 7 The scanner automatically detects which cable it is attached to either an RS 232 or a Synapse cable If it is attach...

Страница 41: ...Defaults 5 7 RS 232 Host Type Standard 5 8 Sleep Time 10 seconds 5 11 Date Separator Forward Slash 5 12 Hour Type 12 Hour 5 13 Decimal Separator Decimal Point 5 14 Date Format MM DD YYYY 5 15 Key Clic...

Страница 42: ...5 30 Transmit UPC E Check Digit Enable 5 30 Transmit UPC E1 Check Digit Enable 5 30 UPC A Preamble System Character 5 31 UPC E Preamble System Character 5 32 UPC E1 Preamble System Character 5 33 Con...

Страница 43: ...Code 39 Check Digit Disable 5 48 Code 39 Full ASCII Conversion Disable 5 49 Convert Code 39 to Code 32 Disable 5 50 Code 93 Code 93 Disable 5 51 Set Length s for Code 93 4 55 5 52 Interleaved 2 of 5 I...

Страница 44: ...ting Disable 5 66 NOTIS Editing Disable 5 67 MSI Plessey MSI Plessey Disable 5 68 Set Length s for MSI Plessey Any Length 5 70 MSI Plessey Check Digits One 5 71 Transmit MSI Plessey Check Digit Disabl...

Страница 45: ...Receive Errors Disable 5 81 Hardware Handshaking None 5 83 Software Handshaking None 5 84 Host Serial Response Time out 2 Sec 5 86 RTS Line State cable use only Low 5 87 Stop Bit Select 1 5 88 ASCII...

Страница 46: ...5 7 Parameter Menus Set Default Parameter Scanning this bar code returns all parameters to the values listed in Table 5 1 SET ALL DEFAULTS...

Страница 47: ...AULTS bar code on page 5 7 Table 5 2 Terminal Specific RS 232C Parameter Standard ICL FUJITSU NIXDORF Mode A Mode B Transmit Code ID No Yes Yes Yes Data Transmission Format Data as is Data Suffix Data...

Страница 48: ...m the Transmit Code ID feature The Transmit Code ID feature should not be enabled for these hosts Table 5 3 Terminal Specific Code ID Characters ICL FUJITSU NIXDORF UPC A A A A UPC E E E C0 EAN 8 FF F...

Страница 49: ...canner Product Reference Guide HostType RS 232C HostTypes Scan the appropriate bar code below to select an RS 232C Host Interface STANDARD RS 232C ICL RS 232C NIXDORF RS 232C Mode A NIXDORF RS 232C Mo...

Страница 50: ...ll or a key press First scan this bar code then enter a range from 05 to 32 using the numeric bar codes on page 5 90 It can stay awake from 5 seconds to 32 seconds Note Allowing the scanner to stay aw...

Страница 51: ...ies Scanner Product Reference Guide Date Separator Scan the appropriate bar code below to select which separator to use when displaying the date Choose FORWARD SLASH DASH COLON or NONE FORWARD SLASH D...

Страница 52: ...5 13 Parameter Menus HourType Scan the appropriate bar code below to select how to display the hour and transmit it to the host device Choose 12 HOUR 6 00 pm or 24 HOUR 18 00 24 HOUR 12 HOUR...

Страница 53: ...canner Product Reference Guide Decimal Separator Scan the appropriate bar code below to select what separator to display when you hit the decimal point key on the keypad Choose DECIMAL POINT or COMMA...

Страница 54: ...arameter Menus Date Format Scan the appropriate bar code below to select how to format the date when it is displayed and transmitted to the host device Choose MM DD YYYY or DD MM YYYY MM DD YYYY DD MM...

Страница 55: ...5 16 Phaser Series Scanner Product Reference Guide Key Click Scan the appropriate bar code below to select whether the keypad click is enabled or not Choose ENABLE or DISABLE ENABLE DISABLE...

Страница 56: ...Parameter Menus BeeperTone Scan the appropriate bar code below to select a decode beep frequency tone Choose LOW FREQUENCY MEDIUM FREQUENCY or HIGH FREQUENCY LOW FREQUENCY MEDIUM FREQUENCY HIGH FREQU...

Страница 57: ...8 Phaser Series Scanner Product Reference Guide BeeperVolume Scan the appropriate bar code below to select a beeper volume Choose LOW VOLUME MEDIUM VOLUME or HIGH VOLUME LOWVOLUME MEDIUMVOLUME HIGHVOL...

Страница 58: ...onds Scan the bar code below to set a Laser On Time Next scan two numeric bar codes beginning on page 5 90 that correspond to the desired time Time less than 1 0 second must have a leading zero For ex...

Страница 59: ...ode Scan the appropriate bar code below to select whether or not the scanner beeps after a good decode If DO NOT BEEP is selected the beeper still operates during parameter menu scanning and indicates...

Страница 60: ...n the appropriate bar code below to select whether or not a No Read message is transmitted When enabled if a symbol does not decode NR is transmitted When disabled if a symbol does not read nothing is...

Страница 61: ...ls increase the scanner s aggressiveness decreases Select the security level appropriate for your bar code quality Note Does not apply to Code 128 Linear Security Level 1 The following code types must...

Страница 62: ...ust be successfully read twice before being decoded The following codes must be read three times LINEAR SECURITY LEVEL 3 Linear Security Level 4 All code types must be successfully read three times be...

Страница 63: ...rameter is only valid when a Linear Code Type Security Level see page 5 22 is enabled When this parameter is enabled a bar code must be successfully scanned in both directions forward and reverse befo...

Страница 64: ...Parameter Menus Enable Disable UPC E UPC A UPC E1 Scan the appropriate bar code below to enable or disable UPC E or UPC A ENABLE UPC E DISABLE UPC E ENABLE UPC A DISABLE UPC A ENABLE UPC E1 DISABLE UP...

Страница 65: ...Phaser Series Scanner Product Reference Guide Enable Disable EAN 8 EAN 13 Scan the appropriate bar code below to enable or disable EAN 8 or EAN 13 ENABLE EAN 8 DISABLE EAN 8 ENABLE EAN 13 DISABLE EAN...

Страница 66: ...5 27 Parameter Menus Enable Disable Bookland EAN Scan the appropriate bar code below to enable or disable Bookland EAN ENABLE BOOKLAND EAN DISABLE BOOKLAND EAN...

Страница 67: ...EAN with supplementals is selected UPC EAN symbols with supplemental characters are decoded and the supplemental characters are ignored t If Autodiscriminate UPC EAN supplementals is selected UPC EAN...

Страница 68: ...o to 20 times Five or above is recommended when decoding a mix of UPC EAN symbols with and without supplementals and the autodiscriminate option is selected Scan the bar code below to select a decode...

Страница 69: ...an the appropriate bar code below to transmit the symbol with or without the UPC A UPC E or UPC E1 check digit TRANSMIT UPC A CHECK DIGIT DO NOTTRANSMIT UPC A CHECK DIGIT TRANSMIT UPC E CHECK DIGIT DO...

Страница 70: ...d to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the symbol NO PREAMBL...

Страница 71: ...bols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the sy...

Страница 72: ...ed to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the symbol NO PREAMB...

Страница 73: ...ded data to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit Scanning DO NOT CONVERT UPC E TO UPC A...

Страница 74: ...A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit Scanning DO NOT CONVERT UPC E1 TO UPC A allows you to t...

Страница 75: ...Extend If this parameter is enabled five leading zeros are added to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols Disabling this parameter returns EAN 8 symbols to their n...

Страница 76: ...EAN Zero Extend is enabled this parameter gives you the option of labeling the extended symbol as either an EAN 13 bar code or an EAN 8 bar code When EAN Zero Extend is disabled this parameter has no...

Страница 77: ...necessary for any given application UPC EAN Security Level 0 This is the default setting which allows the scanner to operate in its most aggressive state while providing sufficient security in decodi...

Страница 78: ...2 UPC EAN Security Level 3 If you have tried Security Level 2 and are still experiencing misdecodes select this security level Be advised that selecting this option is an extreme measure against mis d...

Страница 79: ...e When this parameter is enabled the Phaser decodes UPC A UPC A with 2 supplemental characters UPC A with 5 supplemental characters and UPC A EAN128 bar codes UPC A with supplemental characters need n...

Страница 80: ...Disable Code 128 Scan the appropriate bar code below to enable or disable Code 128 ENABLE CODE 128 DISABLE CODE 128 Note The character and the NULL character cannot be embedded in the barcode to be s...

Страница 81: ...le UCC EAN 128 Scan the appropriate bar code below to enable or disable UCC EAN 128 See Appendix A for details on UCC EAN 128 ENABLE UCC EAN 128 DISABLE UCC EAN 128 Lengths for Code 128 No length sett...

Страница 82: ...5 43 Parameter Menus Enable Disable Code 39 Scan the appropriate bar code below to enable or disable Code 39 ENABLE CODE 39 DISABLE CODE 39...

Страница 83: ...contain six characters Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously If you get an error beep when enabling Trioptic Code 39 disable Code 39 Full ASCII and try again To enab...

Страница 84: ...ted length For example if you select Code 39 One Discrete Length then scan 1 4 only Code 39 symbols containing 14 characters are decoded Numeric bar codes begin on page 5 90 If you make an error or wi...

Страница 85: ...between 4 and 12 characters first scan Code 39 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 5 90 If you mak...

Страница 86: ...this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms Only those Code 39 symbols which include a modulo 43 check digit are decoded when this parameter...

Страница 87: ...er Product Reference Guide Transmit Code 39 Check Digit Scan the appropriate bar code below to transmit the data with or without the check digit TRANSMIT CODE 39 CHECK DIGIT ENABLE DO NOTTRANSMIT CODE...

Страница 88: ...r preceding a Code 39 character and assigns an ASCII character value to the pair For example when Code 39 Full ASCII is enabled and a B is scanned it is interpreted as b J as and H emulates the keystr...

Страница 89: ...vert Code 39 to Code 32 Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 Note Code 39 must be enabled in order for this parameter to function CONVERT CODE 39TO CO...

Страница 90: ...5 51 Parameter Menus Enable Disable Code 93 Scan the appropriate bar code below to enable or disable Code 93 ENABLE CODE 93 DISABLE CODE 93...

Страница 91: ...lect Code 93 One Discrete Length then scan 1 4 only Code 93 symbols containing 14 characters are decoded Numeric bar codes begin on page 5 90 If you make an error or wish to change your selection scan...

Страница 92: ...12 characters first scan Code 93 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 5 90 If you make an error or w...

Страница 93: ...aser Series Scanner Product Reference Guide Enable Disable Interleaved 2 of 5 Scan the appropriate bar code below to enable or disable Interleaved 2 of 5 ENABLE INTERLEAVED 2 OF 5 DISABLE INTERLEAVED...

Страница 94: ...crete Length then scan 1 4 the only I 2 of 5 symbols decoded are those containing 14 characters Numeric bar codes begin on page 5 90 If you make an error or wish to change your selection scan CANCEL o...

Страница 95: ...rst scan I 2 of 5 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 5 90 If you make an error or wish to change y...

Страница 96: ...cation When enabled this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm either USS Uniform Symbology Specification or OPCC Optical Product Code C...

Страница 97: ...r Product Reference Guide Transmit I 2 of 5 Check Digit Scan the appropriate bar code below to transmit the data with or without the check digit TRANSMIT I 2 of 5 CHECK DIGIT ENABLE DO NOTTRANSMIT I 2...

Страница 98: ...f 5 code into EAN 13 and transmits to the host as EAN 13 In order to accomplish this the I 2 of 5 code must be enabled one length must be set to 14 and the code must have a leading zero and a valid EA...

Страница 99: ...60 Phaser Series Scanner Product Reference Guide Enable Disable Discrete 2 of 5 Scan the appropriate bar code below to enable or disable Discrete 2 of 5 ENABLE DISCRETE 2 OF 5 DISABLE DISCRETE 2 OF 5...

Страница 100: ...ete Length then scan 1 4 the only D 2 of 5 symbols decoded are those containing 14 characters Numeric bar codes begin on page 5 90 If you make an error or wish to change your selection scan CANCEL on...

Страница 101: ...t scan D 2 of 5 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 5 90 If you make an error or wish to change you...

Страница 102: ...5 63 Parameter Menus Enable Disable Codabar Scan the appropriate bar code below to enable or disable Codabar ENABLE CODABAR DISABLE CODABAR...

Страница 103: ...elect Codabar One Discrete Length then scan 1 4 the only Codabar symbols decoded are those containing 14 characters Numeric bar codes begin on page 5 90 If you make an error or wish to change your sel...

Страница 104: ...12 characters first scan Codabar Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 5 90 If you make an error or w...

Страница 105: ...If enabled this parameter strips the start and stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar symbol Note Symbol length does not include star...

Страница 106: ...5 67 Parameter Menus NOTIS Editing If enabled this parameter strips the start and stop characters from a decoded Codabar symbol ENABLE NOTIS EDITING DISABLE NOTIS EDITING...

Страница 107: ...5 68 Phaser Series Scanner Product Reference Guide Enable Disable MSI Plessey Scan the appropriate bar code below to enable or disable MSI Plessey ENABLE MSI PLESSEY DISABLE MSI PLESSEY...

Страница 108: ...ngth then scan 1 4 the only MSI Plessey symbols decoded are those containing 14 characters Numeric bar codes begin on page 5 90 If you make an error or wish to change your selection scan CANCEL on pag...

Страница 109: ...SI Plessey Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 5 90 If you make an error or wish to change your sel...

Страница 110: ...ts These check digits at the end of the bar code verify the integrity of the data At least one check digit is always required Check digits are not automatically transmitted with the data ONE MSI PLESS...

Страница 111: ...duct Reference Guide Transmit MSI Plessey Check Digit Scan the appropriate bar code below to transmit the data with or without the check digit TRANSMIT MSI PLESSEY CHECK DIGIT ENABLE DO NOTTRANSMIT MS...

Страница 112: ...essey Check Digit Algorithm When the two MSI Plessey check digits option is selected an additional verification is required to ensure integrity Either of the two following algorithms may be selected M...

Страница 113: ...precedes the decoded symbol The user may select no code ID character a Symbol Code ID character or an AIM Code ID character The Symbol Code ID characters are listed below see Appendix A for AIM Identi...

Страница 114: ...5 75 Parameter Menus Transmit Code ID Character Cont d SYMBOL CODE ID CHARACTER AIM CODE ID CHARACTER NONE...

Страница 115: ...set by scanning the bar code below followed by a two digit number i e two bar codes and are measured in 1 10 second intervals For example scanning bar codes 0 and 1 inserts a 1 10 second pause 0 and 5...

Страница 116: ...is the number of bits of data transmitted per second The scanner s baud rate setting should match the data rate setting of the host device If not data may not reach the host device or may reach it in...

Страница 117: ...5 78 Phaser Series Scanner Product Reference Guide Baud Rate Cont d BAUD RATE 4800 BAUD RATE 9600 BAUD RATE 19 200 BAUD RATE 38 400...

Страница 118: ...to host device requirements If you select ODD parity the parity bit has a value 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character ODD If you select EVEN...

Страница 119: ...er Series Scanner Product Reference Guide Parity Cont d Select MARK parity and the parity bit is always 1 MARK Select SPACE parity and the parity bit is always 0 SPACE If no parity is required select...

Страница 120: ...eceive Errors Select whether or not the parity framing and overrun of received characters are checked The type of parity used is selectable through the PARITY parameter CHECK FOR RECEIVED ERRORS DO NO...

Страница 121: ...ed the scanner sounds a transmit error and discards the data t When data transmission is complete the scanner negates RTS 10 msec after sending the last character t The host should respond by negating...

Страница 122: ...aking is desired NONE Scan the bar code below to select Standard RTS CTS Hardware Handshaking STANDARD RTS CTS When RTS CTS Option 1 is selected the cradle asserts RTS before transmitting and ignores...

Страница 123: ...ansmission regardless of the state of CTS The scanner waits up to two seconds default for CTS to be asserted If CTS is not asserted during this time the scanner issues an error indication and discards...

Страница 124: ...cradle waits up to the programmable Host Serial Response Time out to receive an ACK or NAK If the cradle does not get a response in this time it issues an error indication and discards the data There...

Страница 125: ...received during a transmission Data transmission then stops after sending the current byte When the scanner receives an XON character it sends the rest of the data message The scanner waits indefinite...

Страница 126: ...plies to the scanner in corded mode It has no affect when uploading data through the cradle Scan the appropriate bar code below to set the idle state of the Serial Host RTS line Choose LOW RTS line st...

Страница 127: ...iving device for the next character in the serial data stream The number of stop bits one or two selected depends on the number the receiving terminal is programmed to accommodate Set the number of st...

Страница 128: ...rcharacter delay option matching host requirements The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters The delay period can range fro...

Страница 129: ...5 90 Phaser Series Scanner Product Reference Guide Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1 2 3 4...

Страница 130: ...5 91 Parameter Menus Numeric Bar Codes Cont d 5 6 7 8 9...

Страница 131: ...5 92 Phaser Series Scanner Product Reference Guide Numeric Bar Codes Cont d Cancel If you make an error or wish to change your selection scan the bar code below CANCEL...

Страница 132: ...GS control character When AIM symbology identifiers are transmitted the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines For example c1 indicates a...

Страница 133: ...FNC1ABCDFNC1E will be read as ABCD29E ABCDFNC1E can not be read ABCDE can not be read Enable Disable Read only symbols without leading FNC 1 Examples FNC1ABCDFNC1E can not be read AFNC1BCDFNC1E can no...

Страница 134: ...re Flag Character ASCII 93 c Code Character see Table A 2 m Modifier Character see Table A 3 Table A 2 Code Characters Code Character Code Type A Code 39 C Code 128 EAN 128 E UPC EAN F Codabar G Code...

Страница 135: ...nd stripped check character Example A Full ASCII bar code with check character W A I MI DW is transmitted as A7AimId where 7 3 4 Trioptic Code 39 0 No option specified at this time Always transmit 0 E...

Страница 136: ...stripped before transmission 3 Two check digits verified and stripped before transmission Example An MSI Plessey bar code 4123 with a single check digit checked is transmitted as M04123 D 2 of 5 0 No...

Страница 137: ...UPC chars terminator In the Phaser however the format is changed to E0 UPC chars E2 supplemental Therefore a UPC with two supplemental characters 01234567890510 is transmitted to the host as a 21 char...

Страница 138: ...1027 A CTRL 1004 D CTRL D 1028 B CTRL 1005 E CTRL E 1029 C CTRL 1006 F CTRL F 1030 D CTRL 6 1007 G CTRL G 1031 E CTRL 1008 H CTRL H 1032 Space Space 1009 I CTRL I 1033 A 1010 J CTRL J 1034 B 1011 K C...

Страница 139: ...1051 3 3 1076 L L 1052 4 4 1077 M M 1053 5 5 1078 N N 1054 6 6 1079 O O 1055 7 7 1080 P P 1056 8 8 1081 Q Q 1057 9 9 1082 R R 1058 Z 1083 S S 1059 F 1084 T T 1060 G 1085 U U 1061 H 1086 V V 1062 I 10...

Страница 140: ...ar Keystroke 1098 B b 1113 Q q 1099 C c 1114 R r 1100 D d 1115 S s 1101 E e 1116 T t 1102 F f 1117 U u 1103 G g 1118 V v 1104 H h 1119 W w 1105 I i 1120 X x 1106 J j 1121 Y y 1107 K k 1122 Z z 1108 L...

Страница 141: ...LT Z 2069 ALT E 2080 ALT P 2091 ALT 2070 ALT F 2081 ALT Q 2092 ALT 2071 ALT G 2082 ALT R 2093 ALT 2072 ALT H 2083 ALT S 2094 ALT 6 2073 ALT I 2084 ALT T 2095 ALT 2074 ALT J 2085 ALT U Misc Key Keystro...

Страница 142: ...4008 PF 8 4016 PF 16 4024 PF 24 F Keys Keystroke F Keys Keystroke F Keys Keystroke 5001 F 1 5014 F 14 5027 F 27 5002 F 2 5015 F 15 5028 F 28 5003 F 3 5016 F 16 5029 F 29 5004 F 4 5017 F 17 5030 F 30...

Страница 143: ...Num Lock 6046 6063 5 6060 00 6047 6064 6 6048 0 6065 7 Extended Keypad Keystroke Extended Keypad Keystroke Extended Keypad Keystroke 7001 Break 7008 Backspace 7015 Up Arrow 7002 Delete 7009 Tab 7016 D...

Страница 144: ...isable code 39 full ASCII 5 50 enable disable code 93 5 52 enable disable discrete 2 of 5 5 61 enable disable EAN 8 EAN 13 5 27 enable disable interleaved 2 of 5 5 55 enable disable MSI plessey 5 69 e...

Страница 145: ...g 4 1 4 2 replacing 4 2 Battery Check 3 7 battery life 2 5 beeper indications 4 6 beeper operation 4 4 Bullets v C cable 2 1 installing 2 1 charge status indicator light 1 2 charge status LED indicati...

Страница 146: ...tch 4 4 POS Application 3 4 power options 2 4 print contrast minimum 4 4 R Related Publication vi Returns to Application 3 8 roll tolerance 4 4 S Scan Parameters 3 7 scan repetition rate 4 4 scanner e...

Страница 147: ...__ please include revision level How familiar were you with this product before using this manual Did this manual meet your needs If not please explain ________________ _______________________________...