background image

L

S

 

6

0

0

0

 

S

e

r

i

e

s

Содержание LS6004i-I000

Страница 1: ...L S 6 0 0 0 S e r i e s...

Страница 2: ...5 235 167 5 243 655 5 247 162 5 250 791 5 250 792 5 260 553 5 262 627 5 262 628 5 266 787 5 278 398 5 280 162 5 280 163 5 280 164 5 280 498 5 304 786 5 304 788 5 306 900 5 321 246 5 324 924 5 337 361...

Страница 3: ...synchro nous terminals and host systems It also accommodates Synapse Smart Cables which allow you to connect to a wide variety of host systems LS6004i I090 RS 232C with EAS also supports Checkpoint VI...

Страница 4: ...uide If the scanner is inactive for more than a pre programmed length of time it enters a rest mode to conserve energy When you need to scan again just bring a bar code to the scanner window to wake u...

Страница 5: ...e cable 3 Follow the steps for Installing the Scanner Cable to connect a new cable Electronic Article Surveillance EAS Optional Because there are several Checkpoint EAS systems available your local Ch...

Страница 6: ...s a sin gle scan line to decode then reverts back to omnidirectional constant on This mode is only for hand held use Triggered Omnidirectional Mode Default An omnidirectional scan pattern activates up...

Страница 7: ...or from side to side in a sweeping motion swipe scanning When the LS 6000 is removed from the Presentation Stand the scanner operates in the programmed trigger mode see page 4 for trigger mode descri...

Страница 8: ...to scan or a flash download cable is attached Momentary flash off A bar code has been successfully decoded Fast double blinking The scanner is in a programming sequence Fast sequential flashing A scan...

Страница 9: ...odes Set Defaults Scanning this bar code sets all parameters to their default values SET DEFAULTS Host Type If you re using a Synapse cable Synapse autodetects the type of host you re using so no bar...

Страница 10: ...nterface scan the appropriate bar code below Note To properly communicate with 468X 9X terminals the driver corresponding to the port being used must be loaded and enabled when you are configuring you...

Страница 11: ...n Format Data as is Data Suffix Data Suffix Data Suffix Suffix CR LF 7013 CR 1013 CR 1013 CR 1013 Baud Rate 9600 9600 9600 9600 Parity Even Even None Odd Hardware Handshaking None RTS CTS Option 3 Non...

Страница 12: ...10 L S 6 0 0 0 S e r i e s RS 232C Host Types LS 6004 Cont d STANDARD RS 232C ICL RS 232C NIXDORF RS 232C MODE A NIXDORF RS 232C MODE B FUJITSU RS 232C...

Страница 13: ...11 Q u i c k R e f e r e n c e USB Host Types LS 6007 Default USB Type IBM Hand Held USB Default IBM Table Top USB HID Keyboard Emulation Symbol Native USB Symbol COM Port Emulation...

Страница 14: ...one of the following trigger modes Triggered Omnidirectional Mode Triggered Single Scan Line Mode Combination Mode Hand Held only TRIGGERED OMNIDIRECTIONAL MODE TRIGGERED SINGLE SCAN LINE MODE COMBINA...

Страница 15: ...13 Q u i c k R e f e r e n c e Beeper Frequency To select a decode beep frequency tone scan the appropriate bar code MEDIUM FREQUENCY LOW FREQUENCY HIGH FREQUENCY...

Страница 16: ...values are set by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals See the LS 6000 Product Reference Guide for conversion information Numeric bar co...

Страница 17: ...15 Q u i c k R e f e r e n c e Numeric Bar Codes After scanning the SCAN PREFIX or SCAN SUFFIX bar code scan four numeric bar codes to set the value 0 1 2 3...

Страница 18: ...16 L S 6 0 0 0 S e r i e s Numeric Bar Codes Cont d 4 5 6 7...

Страница 19: ...17 Q u i c k R e f e r e n c e Numeric Bar Codes Cont d Cancel If you make an error or wish to change your selection scan the bar code below CANCEL 8 9...

Страница 20: ...ta Transmission Format scan the SCAN OPTIONS bar code below Then select one of four options When you have made your selection scan the ENTER bar code on the next page If you make a mistake scan the DA...

Страница 21: ...19 Q u i c k R e f e r e n c e Scan Data Transmission Format Cont d PREFIX DATA PREFIX DATA SUFFIX ENTER DATA FORMAT CANCEL...

Страница 22: ...mercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio...

Страница 23: ...1995 Electromagnetic compatibility EMC Part 4 Testing and measurement techniques Section 4 2 Electrostatic discharge immunity test IEC 1000 4 3 1997 Electromagnetic Compatibility EMC Part 4 Testing an...

Страница 24: ...eir intended purpose The following statement is required to comply with US and international regulations Caution Use of controls adjustments or performance of procedures other than those specified her...

Страница 25: ...NS CET APPAREIL NUM RIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU R GLEMENT SUR LE MAT RIEL BROUILLEUR DU CANADA IEC CLASS 1 LASER PRODUCT TIME BASIS 100 S APPAREIL LASER DE CLASSE 1 BASE DE T...

Страница 26: ...STIRR INN I LYSSTR LEN NIET IN STRAAL STAREN LASERPRODUKT KLASSE 2 KLASSE 2 LASERPRODUKT FINNISH PORTUGUESE LUOKKA 1 LUOKKA 1 LASERTUOTE CLASSE 1 PRODUTO LASER DA CLASSE 1 LUOKKA 2 LASERVALO CLASSE 2...

Страница 27: ...freight and insurance prepaid in North America Shipments from the US or other locations will be made F O B Symbol s manufacturing plant Symbol will use new or refurbished parts at its discretion and w...

Страница 28: ...he equipment they will contact the Symbol Support Center United States 1 800 653 5350 Canada 905 629 7226 United Kingdom 0800 328 2424 Asia Pacific 337 6588 Australia 1 800 672 906 Austria 1 505 5794...

Отзывы: