A-2
LS 400Xi Product Reference Guide
Table A-1. Reading Standard Code128 & UCC/EAN 128
Standard Code
128
UCC/EAN-
128
Effect and Example
Disable
Disable
No Code 128 symbols can be read.
Disable
Enable
Read only symbols with leading FNC 1.
Examples:
FNC1
ABCD
FNC1
E are read as ABCD
29
E
A
FNC1
BCD
FNC1
E are read as ABCD
29
E
FNC1FNC1
ABCD
FNC1
E are read as ABCD
29
E
ABCD
FNC1
E cannot be read
ABCDE cannot be read
Enable
Disable
Read only symbols without leading FNC 1.
Examples:
FNC1
ABCD
FNC1
E cannot be read
A
FNC1
BCD
FNC1
E cannot be read
FNC1FNC1
ABCD
FNC1
E cannot be read
ABCD
FNC1
E is read as ABCD
29
E
ABCDE is read as ABCDE
Enable
Enable
Read both types of symbols.
Examples:
FNC1
ABCD
FNC1
E are read as ABCD
29
E
A
FNC1
BCD
FNC1
E are read as ABCD
29
E
FNC1FNC1
ABCD
FNC1
E are read as ABCD
29
E
ABCD
FNC1
E is read as ABCD
29
E
ABCDE is read as ABCDE
Содержание LS 400Xi
Страница 29: ...4 4 LS 400Xi Product Reference Guide LS 400Xi 1 D Decode Zone Figure 4 1 LS 400Xi 1 D Decode Zone...
Страница 110: ...5 77 Parameter Menus Transmit Code ID Character Cont d SYMBOL CODE ID CHARACTER AIM CODE ID CHARACTER NONE...
Страница 114: ...5 81 Parameter Menus Scan DataTransmission Format Cont d PREFIX DATA PREFIX DATA SUFFIX ENTER DATA FORMAT CANCEL...
Страница 116: ...5 83 Parameter Menus Baud Rate Cont d BAUD RATE 4800 BAUD RATE 9600 BAUD RATE 19 200 BAUD RATE 38 400...
Страница 127: ...5 94 LS 400Xi Product Reference Guide Numeric Bar Codes Cont d 5 6 7 8 9...
Страница 128: ...5 95 Parameter Menus Cancel If you make an error or wish to change your selection scan the bar code below CANCEL...