4
WALL ANCHOR SAFETY CABLE
The use of WALL ANCHOR SAFETY CABLE is highly recommended in order to reduce
the risk of the fireplace being tipped over accidentally. WARNING: This CABLE may re-
duce possible risk of injury if the fireplace is improperly handled, but is not a substitute
for proper adult supervision. Children should not be left unattended near any heater.
1. Drill a 5/16” (8 mm) hole in the wall. Insert the PLASTIC WALL ANCHOR into the
hole and gently tap until the flange on the anchor is against the wall surface.
2. Position the back edge of the mantel close to the wall.
3. Attach the SAFETY CABLE to the mantel using the SCREW FOR MANTEL.
4. Use the SCREW FOR WALL to attach the other end of SAFETY CABLE to the wall.
5. Make sure all screws are tight.
Wall
OPERATION
After reading complete instructions, confirm all controls on fireplace are in the OFF
position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach, you
may use an extension cord rated for a minimum of 1875 WATTS. Once the fireplace in-
sert has been properly connected to a grounded electrical outlet, it is ready to operate.
OPERATION BY THE CONTROL PANEL
The controls are located behind the grill below the front glass and can be accessed by
pulling the grill from the top, forward and down.
O/I:
Press this button for main power and flame effect. The indicator light will turn on.
See below for other control switches.
1250W:
For heat function - Press this switch while the
O/I
switch is in the ON position.
The indicator light will turn ON.
Temperature Control:
To adjust the temperature to your individual requirements,
turn the temperature control dial to the right (clockwise) to increase the desired tem-
perature and to the left for lower temperature. This temperature control dial can only
be used while the
O/I
switch and 1250W switch are in the ON position.
Note:
When the
O/I
switch is turned off, the heater functions will stop even though
the switches may be in the ON position.
MAINTENANCE
MaiNtENaNcE warNiNg:
Disconnect power and unplug the power cord before attempting any maintenance or
cleaning to reduce the risk of fire, electric shock or damage to persons. The bulbs in
your unit can become extremely hot. Allow at least 10 minutes between turning off the
unit and removing the light bulbs to avoid the accidental burning of the skin.
risk OF FirE: dO NOt ExcEEd tHE rEcOMMENdEd bulb wattagE.
REPLACING THE FLAME EFFECT LIGHT
AND LOG-SET LIGHT BULBS
Step 1: Remove 12 screws on the back of fireplace and open the rear cover.
There are 2 larger screws and 10 smaller screws
Step 2: You will find 1 X 40W Type B-10 bulb under log-set bed.
Step 3: Loosen and remove the burnt out bulb and replace with new bulb.
Step 4: Close the rear cover. Secure the 2 larger screws into the top left corner hole
and bottom right corner holes as shown in the diagram. Secure the 12
smaller screws into the remaining holes. Make sure the screws are in the
correct holes and have been tightened.
Step 5: Plug in the unit