Operation
Read and follow the chapter “Safety information” carefully.
• For operation, unwind the mains cable of the power strip completely and without loops.
• Mount the product in a suitable location. Lay the cable such that nobody will trip over it. Use
suitable padding to protect valuable surfaces against scratches.
• Insert the plug into a properly earthed mains socket (wall socket).
• Connect up to three consumers to the sockets on the power strip.
• If the power strip has an on/off switch (see ‘Technical data'), you can use it to switch all
consumers on or off. The indicator light in the on/off switch illuminates when switched on.
Socket Strip Item No. 1574789, 1732743
This power strip has surge protection. The surge protection is ready when the red warning
light shines.
If the red warning light does not shine, the surge protection has tripped. In this case, the socket
strip may still be used, but surge protection is no longer provided.
The green control light indicates that the protective conductor is available (control light is
activated).
If the socket strip is connected to the mains voltage (and the mains voltage is availa-
ble), but the green control light does not shine, something is wrong with the voltage/
power supply. Unplug the mains plug of the socket strip from the mains socket. Do
not connect any device to the mains socket, but have it checked by an expert.
Care and cleaning
• This product does not require maintenance. This product does not contain any components
that require maintenance. Never attempt to open or disassemble it. Repair or maintenance
work must be carried out by a technician or a specialist repair centre.
• Disconnect the product from the power supply before cleaning.
Never use aggressive detergents, rubbing alcohol or other chemical solutions, as
these may damage the housing or prevent the product from functioning properly.
• Use a dry, lint-free cloth to clean the product.
Disposal
Electronic devices are recyclable waste and must not be placed in household waste.
At the end of its service life, dispose of the product in accordance with applicable
regulatory guidelines.
You thus fulfil your statutory obligations and contribute to environmental protection.
Specifications
See table to the right.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in elec
-
tronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright 2021 by Conrad Electronic SE. *2446231_v2_1021_02_DS_m_4L_(1)
Item No.
Connection data
Total connection load
Earthed mains sockets
Sockets with enhanced contact protection
On/off switch
Overvoltage protection
Length of cable
Cable type
Dimensions
(L
x W x H)
Ambient temperature
Ambient humidity
(relative, non-condensing)
1574789
250 V/AC, 50 Hz, 16
A
3680 W (max.)
6
yes
yes (bipolar)
yes (leakage current 9 kA)
1.4 m
H05VV
-F 3G1.5 mm²
365 x 48 x 52 mm
-10 °C to +50 °C
10% to 90%
1732743
250 V/AC, 50 Hz, 16
A
3680 W (max.)
5
yes
yes (bipolar)
yes (leakage current 9 kA)
1.4 m
H05VV
-F 3G1.5 mm²
320 x 47 x 52 mm
-10 °C to +50 °C
10% to 90%
2446231
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
no
no
1.4 m
H05VV
-F 3G1.5 mm²
180 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445488
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
no
no
1.4 m
H05VV
-F 3G1.5 mm²
180 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445489
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
no
no
3m
H05VV
-F 3G1.5 mm²
180 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445490
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
no
no
3m
H05VV
-F 3G1.5 mm²
180 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445491
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
no
no
4.8 m
H05VV
-F 3G1.5 mm²
180 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445492
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
yes
no
1.4 m
H05VV
-F 3G1.5 mm²
200 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445493
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
yes
no
1.4 m
H05VV
-F 3G1.5 mm²
200 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445494
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
yes
no
2.8 m
H05VV
-F 3G1.5 mm²
200 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445495
230 V/AC, 50 Hz, 16
A
3680 W max.
3
yes
yes
no
2.8 m
H05VV
-F 3G1.5 mm²
200 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445496
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
no
no
1.4 m
H05VV
-F 3G1.5 mm²
310 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445497
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
no
no
1.4 m
H05VV
-F 3G1.5 mm²
310 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445498
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
no
no
2.8 m
H05VV
-F 3G1.5 mm²
310 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445499
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
no
no
2.8 m
H05VV
-F 3G1.5 mm²
310 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445500
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
no
no
4.8 m
H05VV
-F 3G1.5 mm²
310 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445501
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
yes
no
1.4 m
H05VV
-F 3G1.5 mm²
330 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445502
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
yes
no
1.4 m
H05VV
-F 3G1.5 mm²
330 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445503
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
yes
no
2.8 m
H05VV
-F 3G1.5 mm²
330 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %
2445504
230 V/AC, 50 Hz, 16
A
3680 W max.
6
yes
yes
no
2.8 m
H05VV
-F 3G1.5 mm²
330 x 54 x 44 mm
-10 °C to +50 °C
10 % to 90 %