background image

26

11. Setup

To switch to the setup settings, the thermostat must be in 

the position OFF.

Change the values with the buttons “+” and “-”. Keep the re-

spective button pressed for quick adjustment. 
If you do not push any button for approx. 60 seconds, the 

settings made until then are saved and setting mode is left.
Push the OK and SET buttons for 5 seconds to save the input 

and switch to OFF mode.  

Keep SET and OK  

buttons pushed 

for 5 seconds

or

or

Switch 

to the  

next  

setting

Push the OK 

button  

to confirm  

and to  

switch to 

manual  

mode

To set the 

parameters

To set the 

parameters

Содержание 1385634

Страница 1: ...Operating instructions Digital room thermostat Item No 1385634 GB ...

Страница 2: ...atures 8 6 Safety information 8 a Persons Product 8 b Batteries 11 7 Installation 13 8 Inserting or replacing the batteries 17 9 Commissioning and operation 18 a Switching on off 18 b Selection of the operating function 19 c Manual operation 19 d AUTO mode 20 e PROGRAMME mode 21 f Frost protection function 22 GB ...

Страница 3: ... a Temperature calibration 23 b Time setting 24 c Setting the economic temperature 24 d PROGRAMME setting 25 11 Setup 26 12 Error messages display 30 13 Maintenance and cleaning 31 14 Disposal 33 a Product 33 b Batteries 33 ...

Страница 4: ...erating instructions are part of this product They contain important notes on commissioning and handling Also consider this if you pass on the product to any third party Therefore retain these operating instructions for refe rence All company names and product names are trademarks of their respective owners All rights reserved If there are any technical questions please contact International www c...

Страница 5: ...ing symbol is used when your health is at risk This symbol points out particular dangers associated with handling function or operation The arrow symbol indicates special advice and opera ting information Observe the operating instructions ...

Страница 6: ...moisture must be avoided under all circum stances The safety notes and all other information in these operating instructions always have to be observed Any use other than that described above can damage the product and may involve additional risks such as short cir cuit fire electric shock etc No part of this product must be modified or converted This product complies with the statutory national a...

Страница 7: ...ing instructions Up to date operating instructions 1 Open www conrad com downloads in a browser or scan the displayed QR code 2 Select document type and language and enter the item number into the search field After submitting the query you can down load displayed records ...

Страница 8: ...s We do not assume any liability for consequential damage We do not assume any liability for property damage and personal injury caused by improper use or non compli ance with the safety instructions In such cases the war ranty guarantee is voided a Persons Product The unauthorized conversion and or modification of the product is inadmissible for safety and approval reasons CE Do not disassemble i...

Страница 9: ...ammable gases vapours or explosive dust may be or are present There is a danger of explosion Do not attach any objects to the product Never cover the room thermostat There is a danger of fire The manufacturer or supplier does not assume any responsibility for incorrect displays or the conse quences resulting from incorrect displays Servicing or repair must only be carried out by a spe cialist Neve...

Страница 10: ...e device must be turned off and precau tions are to be taken to ensure that it is not used un intentionally Then have the product inspected by a specialist It must be assumed that safe operation is no longer possible if the device shows visible damage the device no longer functions properly the device has been stored under unfavourable conditions for an extended period of time it has been subjecte...

Страница 11: ... lying around openly There is a risk of batteries being swallowed by children or pets If swallowed consult a doctor immediately Always observe the correct polarity plus and mi nus when inserting the batteries Leaking or damaged batteries may cause chemical burns to skin when touched Use adequate protec tive gloves in this case Batteries must not be short circuited taken apart or thrown into fire T...

Страница 12: ...e remove the inserted batteries If batteries are too old they may leak and cause damage to the product which leads to the cancellation of the war ranty guarantee Read the Disposal chapter for instructions on envi ronmentally sustainable disposal of batteries ...

Страница 13: ...istance of approx 1 5 m for this Never cover the room thermostat with any other ob jects The device is only suitable for vertical wall mounting We recommend a mounting height starting at approx 1 5 m Only install the device on a stable basis e g ma sonry Observe the max connection value of the room ther mostat see technical data The installed relay is poten tial free The controller must only be in...

Страница 14: ...t entirely There is the dan ger of losing the housing screw and the square nut Now pull the upper shell of the controller off of the base plate The base plate is attached on a recessed socket with the two enclosed screws The base plate has four indentations for attachment for this purpose Break out the two required attachment openings with a suitable tool Route the mains line through the mains lin...

Страница 15: ... Observe the maximum contact resilience see chap ter Technical Data and the operating instructions of the device that is to be controlled via the room thermo stat on how to set up the circuits 1 Normally open contact NO 2 COM Common 3 Normally closed contact NC E g recircula tion pump L 230 V AC 50 60 Hz Example ...

Страница 16: ... or damaged by this The upper shell is now attached to the base plate again with the housing screw figure 3 The room thermostat must only be operated with the correctly attached and screwed on upper shell If the upper shell is missing or wrongly installed there is a danger to life from electric shock ...

Страница 17: ...king in the battery compartment holder Return the battery holder to the room thermostat Use only alkaline batteries Use only batteries of the specified type Use alkaline batteries for the longest operating duration The product is only approved for operation with 2x 1 5V AAA batteries Micro No other energy supply must be used Replace the batteries when the battery display flashes ...

Страница 18: ...d the button OK to switch off the room thermo stat display OFF PROGRAMME Mode AUTO Mode Time temperature display Symbols for switching times Symbol for time setting Display off Display SET Manual mode Frost protection function Icon Display Celsius Display AM PM ECONOMIC temperature Display calibration LOCK function Heating consumer on Battery display ...

Страница 19: ...s constant increase or reduction of the room temperature In manual mode the symbol is displayed The factory setting for manual mode is 20 C The temperature value set in the factory can be changed For this push the button plus or Push and hold the plus or minus button of the tem perature setting The temperature setting is now acceler ated The set temperature is kept until the mode is changed The de...

Страница 20: ...e changed for the current heating or reduction phase Briefly push the plus or minus button The tempera ture display will change from the current room tempera ture to the set temperature Now push the plus or minus button to change the set temperature Push and hold the plus or minus button of the tempe rature setting The temperature setting is now accelera ted The set temperature is retained until a...

Страница 21: ...utton The temperature display will change from the current room temperature to the set temperature Now push the plus or minus button to change the set temperature for this switching period Push and hold the plus or minus button of the tempera ture setting The temperature setting is now accelerated The set temperature is retained until a different mode is acti vated or the next heating or reduction...

Страница 22: ...event the room temperature to drop below 5 C The frost protection function thus prevents freezing of liq uid based heatings and pipes The frost protection temper ature is fixed at 5 C in the factory and cannot be changed When the thermostat is in the frost protection function the symbol will be displayed ...

Страница 23: ...n for approx 60 seconds the settings made until then are saved and setting mode is left Push the OK button to save the setting and to leave the set ting mode a Temperature calibration This function permits calibrating the thermostat based on a reference value or adjusting it to other thermostats The setting is made in steps of 0 1 C setting range 3 C to 3 C Push SET and OK buttons at the same time...

Страница 24: ... the same time Push SET button Push SET button or or Push plus or minus buttons to set the hours Push plus or minus buttons to set the minutes Push OK button to confirm c Setting the economic temperature The setting is made in steps of 0 1 C setting range 5 C to 35 C factory setting 16 C Push SET and OK buttons at the same time Push SET button 3x or Push plus or minus buttons to set the temperatur...

Страница 25: ...the hours and minutes setting for P2 Push the plus or minus button for the temperature setting of P1 P2 Push plus or minus buttons to set the hours P1 Push the plus or minus button to set the minutes P1 P1 Start of the first switching period temperature con trolled P2 End of the first switching period temperature controlled P3 Start of the second switching period temperature con trolled P4 End of ...

Страница 26: ...nt If you do not push any button for approx 60 seconds the settings made until then are saved and setting mode is left Push the OK and SET buttons for 5 seconds to save the input and switch to OFF mode Keep SET and OK buttons pushed for 5 seconds or or Switch to the next setting Push the OK button to confirm and to switch to manual mode To set the parameters To set the parameters ...

Страница 27: ...ation and deac tivation tempera ture Switch ing hystere sis 0 C 0 2 C 0 5 C 1 0 C Factory setting 1 5 C 2 0 C 2 5 C 3 0 C 3 5 C 4 0 C 2 Display of temper ature or time in the display Temper ature display factory setting 0 Switch ing between tempera ture 8s and time display 2s 1 ...

Страница 28: ...tching condition of the relay contact NO and COM in the OFF condition open 0 closed 1 The relay switch es at a room temper ature below 5 C factory setting 2 4 Lock func tion key lock Off factory setting 0 On 1 ...

Страница 29: ...table room tempera ture 10 C 35 C adjust able in steps of 0 5 C factory setting 35 C Display at 35 C 6 Factory Setting Set param eters to factory setting 0 Indi vidual parame ters to be main tained setting ex works 1 ...

Страница 30: ...30 12 Error messages display The display flashes when the room temperature drops be low 0 C or climbs above 45 C ...

Страница 31: ...damage the device is longer working the device has been stored under unfavourable conditions for an extended period of time or the device has been subjected to heavy stress during trans port Always observe the following safety information before cleaning or servicing the device Live components may be exposed if cover is opened The device must be disconnected from all power sourc es before any serv...

Страница 32: ... procedures described in these operating instructions for insertion replacing the batteries A dry soft and clean cloth is sufficient for cleaning Do not put too much pressure on the display this can cause scratch marks failures of the display or even destroy the display Dust can easily be removed with a long hair soft and clean brush and a vacuum cleaner Never use any aggressive cleaning agents cl...

Страница 33: ...y ordinance to return all used batteries Disposing of them in the house hold waste is prohibited Batteries that contain any hazardous substances are labelled with the adjacent icon to indicate that disposal in domestic waste is forbidden The descriptions for the respective heavy metals are Cd cadmium Hg mercury Pb lead the names are indicated on the battery e g below the rubbish bin symbol shown o...

Страница 34: ...t max 230 V AC 8 A ohmic load 3 5 A inductive load relay potential free NO a NC contact Temperature resolution 0 1 C Temperature setting range 5 C to 35 C 0 1 C steps ad justable Switching hysteresis 0 C to 4 0 C adjustable Display range Integrated measuring sensor NTC 1 Ambient conditions temperature 0 C to 40 C humidity 20 to 85 rela tive non condensing Dimensions H x W x D 86 x 100 x 20 mm ...

Страница 35: ...35 ...

Страница 36: ...nslation reserved Reproduction by any method e g photocopy mi crofilming or the capture in electronic data processing systems require the prior written approval by the editor Reprinting also in part is prohibited This publication represent the technical status at the time of printing Copyright 2016 by Conrad Electronic SE V3_0516_02 VTP ...