EN
10
The device does not have a power switch. The device must be completely disconnected from the power
supply before work is carried out on the opened device. The power supply may only be available after the
work on the device has been completed.
The values of a presetting performed by SycoTec must be checked by the user for correctness.
3.3 Operation
DANGER
During the operation of the product, there is a risk of serious injury to persons and property caused by
moving of flying parts or by unauthorized use.
It must be ensured that all accesses to the moving parts of the system are kept closed during operation.
It must be ensured that all the mounting screws and tools have been adequately fastened.
It must be ensured that the products are used as intended.
A correct operation of the products must be ensured.
It must be ensured that the applicable safety regulations of the respective system are complied with.
The relevant instructions in the operating manual must be followed.
3.4 Transport, Storage, Maintenance and Disposal
The frequency inverter must not be subjected to an unacceptable load. The following factors must be
considered:
Protection against mechanical damage during transportation, handling, etc. must be ensured!
Protection against contamination and moisture must be ensured!
Protection against contact with electronic components must be ensured!
The following storage conditions must be met, if necessary by appropriate measures:
Pollution:
Clean air according to IEC 60664-1, dirt level 2
Storage temperature:
-25 to +55°C (-14 to 104°F) according to EN 61800-2
Relative humidity (storage location): 5 to 95% (no condensation)
A sudden change in temperature and / or humidity must be avoided.
Depending on the ambient conditions, the frequency inverter must be inspected of for cleanliness and
function at regular intervals.
The safety function STO must be checked by being triggered at regular intervals by qualified staff. This
can be done, for example, by opening the safety switch with the motor running or the attempt of starting
the motor with the safety switch open. If required, the test report according to DIN EN 61800-5-2 can be
made available.
The safety function STO has been tested in accordance with DIN EN 61800-5-2 and compliance with the
underlying standard has been confirmed and documented.
Repair and maintenance work, apart from the activities described in this operating manual, must be
performed only by qualified staff.
ATTENTION
•
In the event of modifications by third parties, the licenses become null and void.
•
Use only SycoTec original parts and spare parts.
Before disposing of the frequency inverter, the battery must be removed.
The battery must be disposed of separately.
Содержание e@syDrive 4624
Страница 1: ...Operating Manual EN HF Inverter e syDrive 4624 4625 4626 ...
Страница 2: ......
Страница 22: ...EN 22 5 2 Mounting Frequency Inverter e syDrive 4625 and 4626 ...
Страница 41: ...EN ...
Страница 42: ...EN 2 002 1912 2018 08 C DE original ...