SY SY-3A-40W Скачать руководство пользователя страница 6

 SY-3A-40W 

www.sy.co.uk 

Action

 

Command

 

Response

 

Check the status of the amplifier 
settings 

600% 

A: 1 -> 1 
Volume : 30 
Bass of LINE: 04 
Treble of LINE: 04 
Ducking Off 

Raise MIC / LINE volume 

601% 

Volume of MIC: 51 

Lower MIC / LINE volume 

602% 

Volume of MIC: 50 

Raise LINE volume 

603% 

Volume of LINE: 51 

Lower LINE volume 

604% 

Volume of LINE: 50 

Raise BASS level 

605% 

Bass of LINE: 04 

Lower BASS level 

606% 

Bass of LINE: 03 

Raise TREBLE level 

607% 

Treble of LINE: 04 

Lower TREBLE level 

608% 

Treble of LINE: 03 

Return to default values 

609% 

Init OK 

Toggle ducking mode

(1)

 

610% 

Ducking On 

Direct setting of MIC / LINE volume 

5xx% 
xx is from 00 to 60 

Volume of MIC: 50 

Direct setting of LINE volume 

7xx% 
xx is from 00 to 60 

Volume of LINE: 50 

Direct setting of BASS level 

8xx% 
xx

 is from 

00

 to

 08 

(

804%

 gives flat response) 

Bass of LINE: 04 

Direct setting of TREBLE level 

9xx% 
xx

 is from

 00

 to

 08 

(

904%

 gives flat response) 

Treble of LINE: 04 

Notes: 

1.

 

The response to the Toggle Ducking command (610%) is either 

Ducking On

 or 

Ducking 

Off

, reflecting the new status after sending the command. 

RS232 Commands with ID Values 

The 16 position switch sets an ID value for each SY-3A-40W amplifier when they are connected  

When the 16 position switch is set to 0, the commands given in the above table are used as stated. 

When the 16 position switch is set to a value between 1 and F inclusive, then this ID value must be 
included with any RS232 command. For example, to send the command Set MIC Volume at 60 to unit ID 3, 
issue the command 

3/560%

 out of the PC serial port.

 

 

Содержание SY-3A-40W

Страница 1: ...SY 3A 40W SY Electronics Ltd Unit 7 Worrall Street Salford Greater Manchester M5 4TH United Kingdom Tel 44 0 161 868 3450 Fax 44 0 161 868 3459 www sy co uk Installation Guide 40W Power Amplifier...

Страница 2: ...er microphone input Talk over microphone has three operating modes 48V MIC level or LINE level Auto muting when no input signal present 70V US or 100V EU line speaker output IR control to adjust the a...

Страница 3: ...put 3 5 mm jack used with the IR key pad Speaker output connector 3 way terminal Output terminals for 100V UK EU or 70V US line speakers Safety Instructions To ensure reliable operation of this produc...

Страница 4: ...et to LINE and then try the MIC setting if no sound can be heard even after adjusting the controls on the SY 3A 40W unit Once the two three position switches have been set the remaining audio sources...

Страница 5: ...MIC Increase or decrease the MMIC LINE input volume LINE LINE Increase or decrease the selected line input volume BASS BASS Increase or decrease the bass response TREBLE TREBLE Increase or decrease th...

Страница 6: ...volume 7xx xx is from 00 to 60 Volume of LINE 50 Direct setting of BASS level 8xx xx is from 00 to 08 804 gives flat response Bass of LINE 04 Direct setting of TREBLE level 9xx xx is from 00 to 08 90...

Страница 7: ...SY 3A 40W www sy co uk Figure 1 SY 3A 40W Connection Diagram...

Страница 8: ...contacting SY Technical Support 2 When calling SY Technical Support the following information should be provided Product name and model number Product serial number Details of the fault and any condi...

Отзывы: