V1.0
7
IR Code Setup
RS232 Command
Command Details
SET IR SYS xx yy
Set IR System Code
Where xx and yy define a 16-bit address, each in the range
[00-FF] (Factory default is 00 FF)
SET IR OUTx INy CODE
zz
Set selection IR Data Code {x[1~2], y[1~6], zz[00~FF]}
Define the IR data code to select the inputs and outputs:
Output x is:
1
= Zone 1 output, or
2
= Zone 2 output
Input y is:
1
-
4
= HDMI inputs 1 to 4
5
= DisplayPort input
6
= VGA input
Data value zz is a unique value for the specified input and
output combination.
Default IR values are: Local Remote
HDMI 1 Input
0x80 0x90
HDMI 2 Input
0x82 0x92
HDMI 3 Input
0x84 0x94
HDMI 4 Input
0x86 0x96
DisplayPort Input
0x88 0x98
VGA Input
0x8a 0x9a
GET IR SYS
Get the current IR System Address Code
GET IR OUTx INy CODE
Get IR Data Code for {x[0~2], y[1~6]}
x[0~2] 0 = Both outputs, 1 = Zone 1 output, 2 = Zone 2
output
y[1~6] 1 - 4 = inputs HDMI 1 to 4, 5 = DP, 6 = VGA
SET IR ALL EN/DIS
Use Enable mode to set Zone 1 IR IN to output to both Zone 1
and Zone 2
Use Disable to set Zone 1 IR IN to output only to Zone 1
Using the Web Interface
The SY-HDBT-662 also has a built-in web interface that can also be used to control the
unit for input selections, EDID settings and network management. The default IP settings
are:
Host IP:
192.168.1.239
Gateway:
192.168.1.1
Network mask: 255.255.255.0
TCP Port:
23
DHCP:
Off
These settings can also be used to send the RS232 commands over a LAN connection
with the sender set up as a TCP Client.