Page | 13  

 

3.

 

Operations 
 

3.1.

 

Button Operation 

BUTTON 

FUNCTION 

ON/Mute 

Button 

o

 

Turn  on  the  UPS:  Press  and  hold 

ON/Mute  button

 

for  at  least  2 

seconds to turn on the UPS

o

 

Mute the alarm: After the UPS is turned on in battery mode, press and 
hold this button for at 

least 5 seconds to disable or enable the alarm 

system

. But it is not applied to the situations when warnings or errors 

occur.  

o

 

Up key: Press this button to display  previous selection in  UPS setting 
mode. 

o

 

Switch to UPS self-test mode: Press 

ON/Mute buttons for 5 seconds 

to enter UPS self-testing

 while in AC mode, ECO mode, or converter 

mode. 

OFF/Enter   

Button 

o

 

Turn off the UPS: Press and hold this button at 

least 2 seconds to turn 

off  the  UPS

.  UPS  will  be  in  standby  mode  under  power  normal  or 

transfer to bypass mode if the  bypass enable setting by pressing this 
button.  

o

 

Confirm  selection  key:  Press  this  button  to  confirm  selection  in  UPS 
setting mode.  

Select 

Button 

o

 

Switch LCD message: Press this button to change the LCD message for 
input  voltage,  input  frequency,  battery  voltage,  output  voltage  and 
output frequency. It will return back to default display 

when pausing 

for 10 seconds.

  

o

 

Setting mode: Press and hold this button for 

5 seconds to enter UPS 

setting mode

 when UPS is in standby and bypass mode.  

o

 

Down  key:  Press  this  button  to  display  next  selection  in  UPS  setting 
mode. 

ON/Mute + 

Select 

Button 

o

 

Switch  to  bypass  mode:  When  the  main  power  is  normal, 

press 

ON/Mute  and  Select  buttons  simultaneously  for  5  seconds

.  Then 

UPS will enter to bypass mode. This action will be ineffective when the 
input voltage is out of acceptable range.  

 
 
 

Содержание Online UPS

Страница 1: ...USER MANUAL Online UPS Challenger Series Stand Alone SA 120 VAC 220 VAC Capacity 1 KVA 2 KVA 3 KVA REVISION DESCRIPTION DATE Rev 1 3 Formal Release 2015 08 31...

Страница 2: ...ll result in death or serious injury Warning Caution Unsafe practices that could endanger health safety and cause financial damage Important Any important technical and operating information on the eq...

Страница 3: ...View 6 2 2 Install the UPS 7 2 3 Battery Replacement 9 2 4 Battery Kit Assembly 10 3 Operations 13 3 1 Button Operation 10 3 2 LCD Panel 11 3 3 Audible Alarm 12 3 4 LCD display wordings index 12 3 5 U...

Страница 4: ...NVIRONMENT o Do not install the UPS system near water or in moist environments o Do not install the UPS system where it would be exposed to direct sunlight or near heater o Do not block ventilation ho...

Страница 5: ...EL o Caution Risk of electric shock Even after the unit is disconnected from the mains commercial power components inside the UPS system are still connected to the battery and electrically live and da...

Страница 6: ...could cause battery explosion o Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic o Please replace the fuse only with the same type and amper...

Страница 7: ...stallation and Setup Before installation please inspect the unit Be sure that nothing inside the package is damaged Please keep the original package in a safe place for future use 2 1 Rear Panel View...

Страница 8: ...UPS AC input Input circuit breaker USB communication port RS 232 communication port SNMP intelligent slot option External battery connection only available for L model Output receptacles Output termin...

Страница 9: ...Please follow below steps to position this UPS Stand Alone Installation Step 1 Connect battery wires If using rack UPS the UPS is shipped out from factory without connecting battery wires for safety c...

Страница 10: ...ration a Remove the small cover of the terminal block b Suggest using AWG14 or 2 1mm2 power cords for 3 KVA 208 220 230 240 VAC models Suggest using AWG12 10 or 3 3 mm2 or 5 3 mm2 power cords for 3 KV...

Страница 11: ...UPS monitoring software to fully configure UPS shutdown You may insert provided CD into CD ROM to install the monitoring software If not please follow steps below to download and install monitoring so...

Страница 12: ...rom power outages CAUTION Consider all warnings cautions and notes before replacing batteries 2 4 Battery kit Assembly OPTIONAL NOTICE Please assemble battery kit first before installing it inside of...

Страница 13: ...Page 11 Battery Kit 2 Units Battery Kit 3 Units...

Страница 14: ...Page 12 Battery Kit 6 Units...

Страница 15: ...S UPS will be in standby mode under power normal or transfer to bypass mode if the bypass enable setting by pressing this button o Confirm selection key Press this button to confirm selection in UPS s...

Страница 16: ...nd the codes are listed in details in 3 5 section MUTE OPERATION Indicates that the UPS alarm is disabled OUTPUT BATTERY VOLTAGE INFORMATION Indicates the output voltage frequency or battery voltage V...

Страница 17: ...ORMATION Indicates the input voltage or frequency or battery voltage Vac Input voltage Vdc battery voltage Hz input frequency 3 3 Audible Alarm Battery Mode Sounding every 4 seconds Low Battery Soundi...

Страница 18: ...presents output voltage is 220Vac 230 presents output voltage is 230Vac Default 240 presents output voltage is 240Vac For 110 115 120 127 VAC models you may choose the following output voltage 110 pr...

Страница 19: ...ptions ENA ECO mode enable DIS ECO mode disable Default 05 ECO voltage range setting INTERFACE SETTING Parameter 2 3 Set the acceptable high voltage point and low voltage point for ECO mode Press the...

Страница 20: ...c Default 264Vac For 110 115 120 127 VAC models 125 132 setting the high voltage point from 115Vac to 132Vac Default 132Vac LLS Bypass low voltage point For 208 220 230 240 VAC models 184 225 setting...

Страница 21: ...PS will still charge battery under this mode Battery mode When the input voltage is beyond the acceptable range or power failure and alarm is sounding every 4 second UPS will backup power from battery...

Страница 22: ...Sounding every second Overload Sounding twice every second Battery is not connected Sounding every second Over Charge Sounding every second Over temperature Sounding every second Charger failure Sound...

Страница 23: ...excess loads from UPS output UPS is overloaded Devices connected to the UPS are fed directly by the electrical network via the Bypass Remove excess loads from UPS output After repetitive overloads the...

Страница 24: ...ged Charge the batteries for at least 5 hours and then check capacity If the problem still persists consult your dealer Batteries defect Contact your dealer to replace the battery Warning code is disp...

Страница 25: ...dealer Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table STORAGE TEMPERA...

Страница 26: ...ns or materials without prior notice and without incurring any obligation to make such changes and modifications on SY G products previously or subsequently sold EN62040 3 EN61000 EN62040 2 EN62040 1...

Страница 27: ......

Отзывы: