background image

 

sy.uk

 

9

 

V2.4

 

EDID Settings

 

When using these commands, please note that there are 30 default EDID settings, and 3 User 

programmable EDID memories per video input.

 

For the default EDID memories, the 

x

 value must be in the range 0 to 29 inclusive (leading zeros 

are not required). For the User EDID memories, the value 

x

 must be one of 30, 31 or 32. The full 

list of EDID settings is given on page 4 and the first column indicates the 

zz

 value for the 

SET 

INy EDID zz

 command stated below.

 

Command

 

Description

 

SET INy EDID zz

 

Set input

 y

 EDID to EDID setting

 zz

 

Where 

zz

 is 00 to 29 one of the 30 built-in EDID settings, 

or

 

30, 31, 32 for the three User defined modes.

 

SET INx EDID CY OUTy

 

Copy the EDID from output 

y

 to input 

x

 

SET INx EDID Uz DATA 

XX,

 

Write an EDID data block to input 

x

, see below

 

GET INx EDID

 

Get the EDID setting for input 

x

 (if 

= 0 then the EDID 

states for all eight inputs will be returned)

 

For the 

SET INx EDID Uz DATA XX,

 command, the data block, 

{XX,

…}

, must contain 

128 or 256 hexadecimal values respectively. Each of the hexadecimal values must be represented 

by two ASCII characters and separated by spaces, for example:

 

SET IN1 EDID U1 DATA 00 FF FF FF FF FF FF 00 4C 2D BE 0B 01 00 00 00 
    02 18 01 03 80 59 32 78 0A EE 91 A3 54 4C 99 26 
    0F 50 54 BD EF 80 71 4F 81 C0 81 00 81 80 95 00 
    A9 C0 B3 00 01 01 04 74 00 30 F2 70 5A 80 B0 58 
    8A 00 50 1D 74 00 00 1E 02 3A 80 18 71 38 2D 40 
    58 2C 45 00 50 1D 74 00 00 1E 00 00 00 FD 00 18 
    4B 0F 87 3C 00 0A 20 20 20 20 20 20 00 00 00 FC 
    00 53 41 4D 53 55 4E 47 0A 20 20 20 20 20 01 9A 
    02 03 3A F1 57 61 10 1F 04 13 05 14 20 21 22 5D 
    5E 5F 60 65 66 62 63 64 07 16 03 12 23 09 07 07 
    83 01 00 00 E2 00 0F 6E 03 0C 00 40 00 88 1E 21 
    00 80 01 02 03 04 E3 0F 01 E0 01 1D 80 D0 72 1C 
    16 20 10 2C 25 80 50 1D 74 00 00 9E 66 21 56 AA 
    51 00 1E 30 46 8F 33 00 50 1D 74 00 00 1E 00 00 
    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 

    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 67

 

Ideally, the above example would be placed into a text file and then sent to the SY-MSUHD-88 

switcher using a serial emulation program. The data given above is only an example and may not 

be compatible with the display devices connected to the SY-MSUHD-88 switcher.

 

 

 

Содержание SY-MSUHD-88

Страница 1: ...SY Electronics Ltd 7 Worrall Street Manchester M5 4TH United Kingdom Tel 44 0 161 868 3450 Web sy uk Installation Guide SY MSUHD 88 8x8 HDMI 2 0 4K60 18 Gbps Matrix...

Страница 2: ...nced EQ and amplification of outputs for smooth switching 1080p to 4K up scaling and 4K to 1080p down scaling on each output Scaling allows the displaying of the same input image on displays with diff...

Страница 3: ...is turned off and is not showing an image Use either of the two video selection methods to select and input to that output Video Selections The SY MSUHD 88 front panel controls allow for the selection...

Страница 4: ...DID memories The user EDID memories are independent to each input and can therefore be set differently for each input Each input can also be set to use the EDID information from any of the output disp...

Страница 5: ...ly presents its currently selected EDID setting to the HDMI source device The following is an example of how to change the EDID setting for input 6 User Action Press Input 6 button to view the current...

Страница 6: ...e used to either gain access to the built in web interface or as a control input for sending the same commands as given for the RS232 port through an IP v4 connection Please note that the carriage ret...

Страница 7: ...ables output a large amount of ASCII encoded information that can be too much for systems with a small amount of available memory as this data can be several kilobytes long The H and STA commands shou...

Страница 8: ...OUTx IMAGE ENH 0 Set 1080p to 4K video enhancement mode to bypass SET OUTx IMAGE ENH 1 Set 1080p to 4K video enhancement mode to weak SET OUTx IMAGE ENH 2 Set 1080p to 4K video enhancement mode to med...

Страница 9: ...l values respectively Each of the hexadecimal values must be represented by two ASCII characters and separated by spaces for example SET IN1 EDID U1 DATA 00 FF FF FF FF FF FF 00 4C 2D BE 0B 01 00 00 0...

Страница 10: ...the DHCP setting GET HIP Get the Host IP address GET NMK Get the subnet mask GET RIP Get the Default Gateway IP address GET TIP Get the TCP IP value GET MAC Get the MAC address When shipped from SY th...

Страница 11: ...Settings Baud rate 57600 n 8 1 Default IP Settings IP Address 192 168 1 239 Subnet 255 255 255 0 Supply Voltage 12V DC Power Consumption 15W max Environmental Operating Temperature Range 0 to 35 C 32...

Страница 12: ...ze of some of these matrix switchers correct Manual Handling and Lifting procedures should be observed at all times while handling these products in order to minimise the risk of injury After Sales Se...

Отзывы: