![SWP Stealth-XG 6044 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/swp/stealth-xg-6044/stealth-xg-6044_operators-manual_1416137015.webp)
14
8. TROUBLE SHOOTING
Problem
Probable cause
Action
Fault code «E01»
+
blinks
1.Motor is stuck
2.Motor is damaged
3.Blower structure failure
caused by outer force
4.Circuit failure
Check and remove physical
failure and restart the system.
Return to dealer if LCD still
shows E01
Fault code «E02»
+
blinks
1.Motor is damaged
2.Motor impeller rubs blower
shell
3.Circuit
has
excessive
current.
Check and remove physical
failure and restart the system.
Return to dealer if LCD still
shows E02
blinks
+
blinks
+ alarm sounds
Low battery
Charge the battery
blinks
+
blinks
+ alarm sounds
Filter blocked
Tube blocked
Remove obstruction, change the
filter
Clean tube
alarm sounds
Battery high temperature
Stop working and rest
No air flow, no alarm
1. No power
2.Battery contact damaged
Charge the battery
Check battery contact
Battery run time is too short
1.Battery is not fully charged
2. Filter is blocked
3. Battery is damaged
Charge the battery
Remove obstruction, change
filter
Change battery
Air supply to hood smells
unusual
1. Filter broken
2. Tube broken
3. ADF helmet broken
Leave current area immediately.
1. Change filter
2. Change tube
3. Change ADF helmet
Supply insufficient air to hood
1. Breathing tube broken off
2. Breathing tube broken
3. Filter is blocked
1. Check tube connection to
hood and respirator system unit
2. Change breathing tube
3.Remove obstruction, change
filter
15
16
9. SPECIFICATION
3.Remove obstruction, change
filter
Size (Blower Assembly)
9-2/5 x 6-1/2 x 2-3/4 in. (240 x 165 x 70 mm)
Weight
2.4KG
Particle Filter
1*TH3 P R SL
Air Flow
Manufacturer minimum design flow rate: 165L/min
Nominal airflow :
Level 1: 170L/min
Level 2: 200L/min
Level 3: 230L/min
Noise Level
Max 75dB
Operate Temperature
23
℉
to 131
℉
(-5
℃
~55
℃
)
Storage temperature
14
℉
to 131
℉
(-10
℃
~55
℃
)
Battery Type
Standard Battery Rechargeable Li-ION 4400mAh
Optional:
Heavy Duty Battery Rechargeable Li-ION 6800mAh
Expected Battery
Operation Time
Standard battery
Level 1>10h
Level 2>8h
Level 3>6h
Heavy Duty battery
(
optional
)
Level 1>15h
Level 2>12h
Level 3>10h
Battery Charging Time
3.5 Hours
5 hours
Battery Life
500 Charges
Run Time Dependent On Air Flow Rate and Filter Load.
LCD Display
Air flow level and data
Battery capacity
Filter status
Belt Size
35-2/5 x 51-2/5 in. (900mm to 1300mm)
Содержание Stealth-XG 6044
Страница 18: ...A T T AUTO DARKENING HELMET 18 Specification of ADF...
Страница 19: ...Battery Life Battery Life T T L L V T T 104 5 Remote 19 MODEL STEALTH XG...
Страница 20: ...20...
Страница 21: ...21...
Страница 22: ...22...
Страница 23: ...23...
Страница 27: ...REPLACE INNER VISOR HEADGEAR ADJUSTMENTS REPLACE OUTER PROTECTION LENS 27...
Страница 28: ...28...
Страница 30: ...30...