5. Installation Plate 

 
           

Installation Plate                                  Rear View of S-4607                                      Installed 

 

 
 
Screw hole 3                    Screw hole 4 
 
 

Screw 
hole 1 

 

 

Screw 
hole 2 

Screw hole 5                    Screw hole 6 
 
 
 
Match the screw holes 1&2 with the threads 1&2 of S-4607, and fix the installation plate to the S-4607 by the 
supplied screws.   
The screw holes 3, 4, 5, 6 are used to install the converter to wall or racks. 
 
 

6. Specifications 

    

Model 

S-4607 

Input 

3G/HD/SD SDI×1 
OPTICAL×1 

Output 

3G/HD/SD SDI loop out ×1, OPTICAL convert out ×1 
3G/HD/SD SDI convert out ×2 
SMPTE-425M 

1080p (60/59.94/50) 

1080p (30/29.97/25/24/23.98) 

SMPTE-274M 

1080i (60/59.94/50) 

SMPTE-296M 

720p (60/59.94/50) 

ITU-R BT.656 

576i (50) 

SDI Format 

SMPTE-125M 

480i (59.94) 

Optical connector 

LC 

Transmission distance 

20km 

Wavelength 

Input: 1310nm; Output: 1260nm~1580nm 

Power consumption 

≤4W 

Working voltage 

DC 6-18V 

Working environment 

Temperature: 0°C -+70°C, Humidity:10%-90% 

Dimension 

98×84×29

 

mm 

Net weight 

200g 

    

7. Maintenance 

 
1. Please do not disassemble the product by yourself. 
2. Keep the product away from rain or moisture. 
3. Please use the provided power adapter and if you use third party power adapter, please make sure the 

voltage range, supplied power, and polarity of power lead are fit. 