Device Overview
1.
Power input
2.
3/8” thread
3.
DMX input port (on transmitter only)
4.
DMX output port (on receiver only)
5.
M10 and M12 thread for clamp
6.
Power indicator
7.
DMX signal indicator
8.
Signal strength indicator (on receiver only)
9.
Link button and Link LED
10.
Antenna connector and antenna
Mains Connection
The user must supply a suitable power cable. The user must then either hard-wire the power cable to the building’s
electrical installation, providing an easily accessible power on/off switch close to the device, or install on the power
cable a grounding-type (earthed) mains plug that is suitable for the local power outlets, following the power plug
manufacturer’s instructions. Consult a qualified electrician, if you have any doubts about proper installation.
A blue
Neutrik powerCON NAC3FCA
cable mount connector must be used to supply power to the XWL.
Warning! For protection from dangerous electric shocks, the device must be grounded (earthed). The
local AC power source must have both overload and ground-fault (earth fault) protection.
Important! The powerCON is a connector without breaking capacity, i.e. the powerCON should not be
connected or disconnected under load or live!
1
2
3
5
1
2
4
5
6
7
6
7
8
9
9
10
10
XWL-T wireless DMX transmitter
XWL-R wireless DMX receiver