Swiss HealthPro 100 Скачать руководство пользователя страница 16

16

Chapter 4

– Using the Control Panel

4.4.5  Timer ON /OFF Fan Speed Selection

The Timer ON /OFF Fan Speed Selection Menu allows the programming of two
different fan speeds for two different time periods (referred to as Timer ON an
Timer OFF periods). For the Timer ON period you can select between fan
speeds 1 to 6. For the Timer OFF period you can select between fan speeds 0
(i.e. off ) to 6.

1.

To reach the Timer ON Fan Speed Selection Menu from the main display
window, press the 

Menu

key four times.

2.

Press and hold the 

Enter

key until the cursor appears. 

3.

Press the 

p

key to select the desired speed for the Timer ON period.

4.

Press the 

Enter

key to confirm the chosen speed and to exit the enter

mode.

5.

To set the fan speed for the Timer OFF period press the 

Menu

key one more

time. Press the 

Enter

key until the cursor appears and adjust the Timer OFF

fan speed as above. The final 

Enter

command saves the selection exits the

enter mode.

4.4.4  Setting the Weekly Timer

The weekly timer allows the activation/deactivation of the Timer ON period on
certain days of the week. In its default setting the timer is enabled on all seven
days of the week. This is indicated by stars below the abbreviations of the days.
On days, without a star, the air cleaner will be running at the speed which is set
in the Timer OFF Fan Speed Selection Menu (see 4.4.5).

Note:

At least one day of the week must be enabled with a star to be able to

run the daily timer. If the timer is disabled on all days of the week, the timer
status field in the Daily Timer Menu will switch to “OFF” and the timer will be
disabled.

1.

To reach the Weekly Timer Menu from the main display window, press the

Menu

key three times.

2.

Press and hold down the 

Enter

key until the cursor appears. 

3.

Press the 

p

key to activate (star) or deactivate (no star) the daily time on a

particular day. Press the 

Enter

key to proceed to the next day.

4.

Repeat the same procedure until the timer has been activated/deac ti va ted
on the desired days. The final 

Enter

command exits the enter mode.

Содержание HealthPro 100

Страница 1: ...Swiss Made 105 10 31 40_140113_IN_MA_HP100_EN CN HealthPro 100 User Manual...

Страница 2: ......

Страница 3: ...danger of dust explosions Do not use this appliance in explosive areas Only use filters and accessories recommended by the manufacturer Do not use outdoors Do not obstruct the air inlet and air outlet...

Страница 4: ...ng the Daily Timer 15 4 4 4 Setting the Weekly Timer 16 4 4 5 Timer ON OFF Fan Speed Selection 16 4 4 6 Timer Information in the Control Panel 17 4 4 7 Time Day Setting 17 4 4 8 Filter Life Reset 18 4...

Страница 5: ...llutants enter the room air is high or the indoor air quality requirements are stringent the hourly air delivery of the system needs to exceed the room air volume several times To achieve that level o...

Страница 6: ...ances a divergence of 10 10m3 h is deemed acceptable Note The air delivery rate refers to the system s initial air delivery which will decrease as filters load up with dust particles Measuring instrum...

Страница 7: ...6 Turn the device upside down on a soft and clean surface Place the mounting rail on the purifier s base so that the holes line up with the black connector pins on the base The cut ins should face the...

Страница 8: ...a wall or a cupboard In general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cable is positioned in a...

Страница 9: ...ures air intake openings on two sides The PreMaxTM filter module consists of frame 1 and the PreMaxTM filter which is fixed inside the frame by four filter clamps The fan assembly comprises two housin...

Страница 10: ...everal square meters of tightly pleated HyperHEPA filter media that removes even the tiniest particles 5 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Descripti...

Страница 11: ...the front locking arm Several operations can be completed via the electronic control panel including Switching the system on and off Controlling the fan speed and corresponding air delivery rate Chec...

Страница 12: ...uced dramatically either due to a reduction in airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed t...

Страница 13: ...ced by the system in a specific environment are calculated as follows hourly air delivery of the system m3 h air changes per hour ACH air volume of the room m3 N B The air delivery rates at the variou...

Страница 14: ...red with an internal memory bank which contains infor mation about the different filters lives under specific conditions of use The Filter Life Monitor makes a calculation of the remaining filter life...

Страница 15: ...splay window press the Menu key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the p key once to activate the timer Note If the start and stop time are identical the tim...

Страница 16: ...tion exits the enter mode 4 4 4 Setting the Weekly Timer The weekly timer allows the activation deactivation of the Timer ON period on certain days of the week In its default setting the timer is enab...

Страница 17: ...the Enter key until the cursor starts to flash 3 Select the hour by pressing the p key 4 Press the Enter key to save the hour setting and to proceed to the minute setting 5 Select the minutes by pres...

Страница 18: ...e main display window press the Menu key ten times The current display language is displayed 2 To change the display language press and hold the Enter key until the cursor starts to flash 3 Use the p...

Страница 19: ...remain airborne for long periods of time This dust group is made up of small combustion particles that are created as the result of combustion processes of automobiles small allergen particles such a...

Страница 20: ...to the Fine Dust index 6 Press and hold the Enter key until the cursor appears 7 Press the p key to modify the Fine Dust index to reflect the fine dust pollution levels found in the environment where...

Страница 21: ...ible to switch the timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch the timer off press the Timer Modification key a...

Страница 22: ...a matter of minutes The illustration of the system on the right side of the control panel shows the positions of the individual filters These positions correspond to the actual positions of the filter...

Страница 23: ...the arm from its snap in position in the diffuser Disengage the other arm in the same way 3 Pull both locking arms evenly outwards until they snap into place and remain open Access to all filter eleme...

Страница 24: ...using For details on how to close the housing please refer to the section 6 3 8 Dispose of the used filter by placing it into the plastic bag in which the new filter is supplied 7 Lift the frame from...

Страница 25: ...see the section 6 7 9 Put frame 2 back into the housing and reposition the diffuser For closing refer to the section 6 3 Frame 2 6 6 Discarding Used Filters Used filters can normally be put into the...

Страница 26: ...wall mounting of the system where floor space is limited InFlow Complete ducting adapter kit for the creation of positive pressure if placed within the room and negative pressure if placed outside th...

Страница 27: ......

Страница 28: ...INCEN AG Blumenfeldstrasse 15 CH 9403 Goldach Switzerland www iqair com uk...

Отзывы: