Menu Key

The 

Menu

key allows access to any one of eleven menus. Pressing the 

Menu

key once allows access to the first

menu function. Pressing the 

Menu

key twice allows access to the second menu function, and so on. If no key is

pressed for 15 seconds in a menu window, the display will revert to the main display window.  

Tip: 

If you are in a

menu window and would like to remain in the window for more than 15 seconds, keep the 

p

key depressed.

Enter Key

The 

Enter

key, if pressed for 3 seconds, allows the modification of a setting. The enter mode is indicated by a

flashing cursor on the modifiable setting. Pressing the 

Enter

key again will save any entry and move the cursor to

the next modifiable item in the display window. When the last modifiable choice in a window is confirmed with the

Enter

key, the enter mode is automatically terminated and the new settings are saved. 

Filter Life LEDs: 

Whenever the system is on, the colour of the filter life LEDs (light emitting diodes) indicates the

state of the in di vidual filters in the system. 

Note:

The positions of the filter life LEDs on the control panel correspond

to the actual positions of the filters within the system. 

The filter life indicator LEDs signal four possible stages in the life of the filter:

1. Green: 

The filter is still within 80% of its estimated life span.

2. Orange:

The filter is approaching the last 20% of its estimated life span.

3. Red:

The filter has reached the end of its estimated life span.

4. Red blinking:

The filter has passed its estimated life span and should be replaced immediately. The system’s
effectiveness is likely to have been reduced dramatically, either due to a reduction in airflow
(particle filters are clogged) or a reduction in filter efficiency (gas phase filter is saturated).

Fan Speed LEDs: 

These LEDs simulate the fan speed through the frequency of their rotation. The faster the rotation

of the fan speed LEDs, the faster the actual fan speed of the unit.

4.2 Control Panel Locking Function

The control panel can be locked to avoid tampering with the settings. To
lock or unlock the control panel keys, the 

Menu

and the 

Enter

key have

to be pressed down simultaneously for 3 seconds. The acti  vated locking
function is indicated with a star symbol in the control panel display. The
locking function is cancelled by disrupting the power supply. 

4.3  Fan Speed and Air Delivery

The system can be set to run at six different fan speeds which correspond to six different airflow rates. Speed 1 is the
lower, speed 6 the highest fan speed. The higher the fan speed, the more room air will be filtered by the system. The
high fan speed settings provide additional air cleaning power to deal with situations of elevated pollution levels.

To allow better evaluation of the system’s performance at different fan speeds, the standard display window shows
not only the fan speed, but also the air delivery rate (airflow). The displayed airflow is factory preset and is not
measured by the system itself.

4.3.1  Regulating Fan Speed

1.

When the system is switched off (standby mode), the first line of the LCD
display shows the model name. To switched the system on, press the

Power

key on the far left of the control panel.

2.

The LCD now displays the fan speed and the corresponding airflow rate.

Note

: The system starts at the fan speed at which it was running when it

was last used.

3.

To change the fan speed, press the 

p

key. 

12

Chapter 4

– Using the Control Panel

Содержание HealthPro 100

Страница 1: ...Swiss Made 105 10 31 40_140113_IN_MA_HP100_EN CN HealthPro 100 User Manual...

Страница 2: ......

Страница 3: ...danger of dust explosions Do not use this appliance in explosive areas Only use filters and accessories recommended by the manufacturer Do not use outdoors Do not obstruct the air inlet and air outlet...

Страница 4: ...ng the Daily Timer 15 4 4 4 Setting the Weekly Timer 16 4 4 5 Timer ON OFF Fan Speed Selection 16 4 4 6 Timer Information in the Control Panel 17 4 4 7 Time Day Setting 17 4 4 8 Filter Life Reset 18 4...

Страница 5: ...llutants enter the room air is high or the indoor air quality requirements are stringent the hourly air delivery of the system needs to exceed the room air volume several times To achieve that level o...

Страница 6: ...ances a divergence of 10 10m3 h is deemed acceptable Note The air delivery rate refers to the system s initial air delivery which will decrease as filters load up with dust particles Measuring instrum...

Страница 7: ...6 Turn the device upside down on a soft and clean surface Place the mounting rail on the purifier s base so that the holes line up with the black connector pins on the base The cut ins should face the...

Страница 8: ...a wall or a cupboard In general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cable is positioned in a...

Страница 9: ...ures air intake openings on two sides The PreMaxTM filter module consists of frame 1 and the PreMaxTM filter which is fixed inside the frame by four filter clamps The fan assembly comprises two housin...

Страница 10: ...everal square meters of tightly pleated HyperHEPA filter media that removes even the tiniest particles 5 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Descripti...

Страница 11: ...the front locking arm Several operations can be completed via the electronic control panel including Switching the system on and off Controlling the fan speed and corresponding air delivery rate Chec...

Страница 12: ...uced dramatically either due to a reduction in airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed t...

Страница 13: ...ced by the system in a specific environment are calculated as follows hourly air delivery of the system m3 h air changes per hour ACH air volume of the room m3 N B The air delivery rates at the variou...

Страница 14: ...red with an internal memory bank which contains infor mation about the different filters lives under specific conditions of use The Filter Life Monitor makes a calculation of the remaining filter life...

Страница 15: ...splay window press the Menu key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the p key once to activate the timer Note If the start and stop time are identical the tim...

Страница 16: ...tion exits the enter mode 4 4 4 Setting the Weekly Timer The weekly timer allows the activation deactivation of the Timer ON period on certain days of the week In its default setting the timer is enab...

Страница 17: ...the Enter key until the cursor starts to flash 3 Select the hour by pressing the p key 4 Press the Enter key to save the hour setting and to proceed to the minute setting 5 Select the minutes by pres...

Страница 18: ...e main display window press the Menu key ten times The current display language is displayed 2 To change the display language press and hold the Enter key until the cursor starts to flash 3 Use the p...

Страница 19: ...remain airborne for long periods of time This dust group is made up of small combustion particles that are created as the result of combustion processes of automobiles small allergen particles such a...

Страница 20: ...to the Fine Dust index 6 Press and hold the Enter key until the cursor appears 7 Press the p key to modify the Fine Dust index to reflect the fine dust pollution levels found in the environment where...

Страница 21: ...ible to switch the timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch the timer off press the Timer Modification key a...

Страница 22: ...a matter of minutes The illustration of the system on the right side of the control panel shows the positions of the individual filters These positions correspond to the actual positions of the filter...

Страница 23: ...the arm from its snap in position in the diffuser Disengage the other arm in the same way 3 Pull both locking arms evenly outwards until they snap into place and remain open Access to all filter eleme...

Страница 24: ...using For details on how to close the housing please refer to the section 6 3 8 Dispose of the used filter by placing it into the plastic bag in which the new filter is supplied 7 Lift the frame from...

Страница 25: ...see the section 6 7 9 Put frame 2 back into the housing and reposition the diffuser For closing refer to the section 6 3 Frame 2 6 6 Discarding Used Filters Used filters can normally be put into the...

Страница 26: ...wall mounting of the system where floor space is limited InFlow Complete ducting adapter kit for the creation of positive pressure if placed within the room and negative pressure if placed outside th...

Страница 27: ......

Страница 28: ...INCEN AG Blumenfeldstrasse 15 CH 9403 Goldach Switzerland www iqair com uk...

Отзывы: