2. Technical specifications
Model
1400
Capacity at air 28°/water 28°C/humidity 80%* kW
5.50
Capacity at air 15°C/water 26°C/humidity 70%* kW
3.80
Power consumption at air 28°C/water 28°C/humidity 80%* kW
1.17
Power consumption at air 15°C/water 26°/humidity 70% * kW
0.95
COP at air 28°C/water 28°/humidity 80%
4.70
COP at air 15°/water 26°/humidity 70%
4.00
Maximum pool volume m
3
20
Recommended pool volume m
3
10-16
Rated Current (A)
5.2
Rated fuse (A)
15
Power Supply V/Ph/HZ
220-240V~50Hz/1PH
Heat exchanger
Titanium in PVC
Number/type of compressors
1 / Rotary - R32
Minimum water flow in operation
>2,500 litres/hour.
Refrigerant R32 grams
400
CO2 equivalent tons
0.44
Fan speed rpm
830 ~ 870
Noise at a distance of 10 metres dB (A)
40
Noise at a distance of 1 metre dB (A)
49
Water connection mm
50 / 38 / 32
Nominal water flow rate m
3
/hour
2.5~3.2
Max. water pressure drop kPa
12
Protection
IPx4
Net dimensions L/W/H mm
789x300x502
Gross dimensions L/W/H mm
850x330x550
Net/Gross weight kg
37/39
*Maximum pool volume when fully insulated with cover, sheltered from the wind and located in full sun.
The above data may be changed without notice.