46
General Care
12.1 Galvanised Chassis
Your RPH chassis is hot dipped galvanised, a
method used for many years throughout the
automotive industry and widely regarded as
one of the best forms of corrosion protection.
When the steel is withdrawn from the
galvanising bath it has a clean, bright surface
which over a period of time changes to a
dull grey colour as the surface zinc reacts
with oxygen, water and carbon dioxide in the
atmosphere to form a tough, stable, protective
layer.
During this time, if galvanised items are stored in
damp or wet conditions, where there is little or
no air movement, then the zinc will continue to
react with the moisture that is present. In doing
so the zinc will produce excessive amounts of
zinc hydroxide which is a bulky white deposit
on the surface of the galvanising and is often
referred to as wet storage stain (white rust).
You can help to prevent wet storage stain (white
rust) occurring by washing the chassis with
clean water as soon as it is delivered allowing an
adequate flow of dry air to ensure it dries out.
Should wet storage stain (white rust) occur it
can be removed using a stiff bristle brush or a
“Scotchbrite” pad. Because of its post process
nature “Wet Storage Stain (white rust)” is not
covered under Warranty procedures.
12.2 External structure
Regularly carry out visual inspections for
damage to panels, gutter and other external
features. Signs of damage, leakage and
movement should be repaired as necessary.
WARNING:
For the Cleaning, Inspection
and maintenance / repair of roofs we
recommend it is carried out by a suitably
competent professional contractor. If access
to the roof is necessary then this should be
properly planned, supervised and carried
out by competent people with the skills,
knowledge and experience to carry out this
activity. The correct equipment must always
be used.
i
Note:
The roof should be inspected for
leaks and rectified as necessary
WARNING:
Ensure that all necessary
working at height safety precautions are in
place before climbing onto the roof.
WARNING:
To avoid damaging the roof, use
a 15mm or thick sheet of plywood or similar
which must be wide enough to span over two
roof spars (approximately 600mm centres). A
sheet 1220mm x 1220mm (4’x 4’) should be
suitable when positioned carefully on the roof.
12.3 Blockages
If you have a waste water or toilet blockage, the
first thing to check is that the site main drainage
is clear as any blockages here could back-up
to your Leisure Lodge. If it is clear and you
have a toilet blockage we would recommend
that you call a plumber, unless you are aware
of what could have caused the problem and
are competent to address the problem. If it is
a waste blockage, you should first check and
clean out traps situated under the sink, basin
and shower tray (if fitted). If you still have a
blockage, then it must be in the feeder pipes to
the main sewerage pipes or the main sewerage
pipe. You should consult a plumber or your park
officer at this stage unless you are competent
to do the job.
Gutters and downpipes
It is important that all gutters and down pipes
are kept free from obstructions and blockages.
Inspect regularly.
12.4 CanExel panels
CanExel prefinished panels are produced from
wood fibre, resin, and wax fused under pressure.
This engineered wood panelling is highly stable,
as well as highly resistant to moisture with a
finish consisting of five coats of baked-on paint
and a sealer top coat.
The cleaning method recommended is to wash
down with plenty of clean water and very mild
detergent.
Содержание Biarritz Lodge 40x13-2 2020
Страница 8: ...9 Warranties 10 AfterSales 12 Swift Connect Direct 12 WARRANTY AND AFTER SALES SUPPORT...
Страница 18: ...19 Siting Figure 4 Typical Support and holding down points Twin unit...
Страница 19: ...20...
Страница 20: ...21 Fire precautions 22 Emergency shut off points 23 GENERAL SAFETY ADVICE...
Страница 23: ...24...
Страница 29: ...30...
Страница 30: ...31 Mains electricity and wiring 32 Bulbs 33 MAINS ELECTRICITY WIRING...
Страница 33: ...34...
Страница 34: ...35 Centralheatingandhotwatersystem 36 Thermalinsulation 36 Ventilation 36 HEATING THERMAL PROPERTIES...
Страница 36: ...37 APPLIANCES...
Страница 38: ...39 COOKING...
Страница 40: ...41 BLINDS...
Страница 42: ...43 Pull out sofa bed 44 Bunk beds 44 BEDS...
Страница 57: ...58...
Страница 58: ...59 Protecting your RPH and possessions 60 SECURITY...
Страница 60: ...61 Winterisation 62 Condensation 63 WINTERISATION...
Страница 64: ...65 External dimensions 66 Model names berths and bed sizes 67 TECHNICAL INFORMATION...
Страница 78: ...79 Single Unit Generic Gas Technical info...
Страница 79: ...80 Single Unit Generic Lighting Technical info...
Страница 81: ...82 Twin Unit Generic Lighting Technical info TWIN LODGE SCHEMATIC 2020...
Страница 82: ...83 Technical info CO AX Schematic LOUNGE OR...
Страница 85: ...86 Notes...