General Care

12.1 Galvanised Chassis

Your RPH chassis is hot dipped galvanised, a 

method used for many years throughout the 

automotive industry and widely regarded as 

one of the best forms of corrosion protection.
When the steel is withdrawn from the 

galvanising bath it has a clean, bright surface 

which over a period of time changes to a 

dull grey colour as the surface zinc reacts 

with oxygen, water and carbon dioxide in the 

atmosphere to form a tough, stable, protective 

layer. 
During this time, if galvanised items are stored in 

damp or wet conditions, where there is little or 

no air movement, then the zinc will continue to 

react with the moisture that is present. In doing 

so the zinc will produce excessive amounts of 

zinc hydroxide which is a bulky white deposit 

on the surface of the galvanising and is often 

referred to as wet storage stain (white rust).
You can help to prevent wet storage stain (white 

rust) occurring by washing the chassis with 

clean water as soon as it is delivered allowing an 

adequate flow of dry air to ensure it dries out.

Should wet storage stain (white rust) occur it 

can be removed using a stiff bristle brush or a 

“Scotchbrite” pad.  Because of its post process 

nature “Wet Storage Stain (white rust)” is not 

covered under Warranty procedures.

12.2 External structure

Regularly carry out visual inspections for 

damage to panels, gutter and other external 

features. Signs of damage, leakage and 

movement should be repaired as necessary.

WARNING: 

For the Cleaning, Inspection 

and maintenance / repair of roofs we 

recommend it is carried out by a suitably 

competent professional contractor. If access 

to the roof is necessary then this should be 

properly planned, supervised and carried 

out by competent people with the skills, 

knowledge and experience to carry out this 

activity. The correct equipment must always 

be used.

i

Note: 

The roof should be inspected for 

leaks and rectified as necessary

WARNING: 

Ensure that all necessary 

working at height safety precautions are in 

place before climbing onto the roof.

WARNING: 

To avoid damaging the roof, use 

a 15mm or thick sheet of plywood or similar 

which must be wide enough to span over two 

roof spars (approximately 600mm centres). A 

sheet 1220mm x 1220mm (4’x 4’) should be 

suitable when positioned carefully on the roof.

12.3 Blockages

If you have a waste water or toilet blockage, the 

first thing to check is that the site main drainage 

is clear as any blockages here could back-up 

to your Leisure Lodge. If it is clear and you 

have a toilet blockage we would recommend 

that you call a plumber, unless you are aware 

of what could have caused the problem and 

are competent to address the problem. If it is 

a waste blockage, you should first check and 

clean out traps situated under the sink, basin 

and shower tray (if fitted). If you still have a 

blockage, then it must be in the feeder pipes to 

the main sewerage pipes or the main sewerage 

pipe. You should consult a plumber or your park 

officer at this stage unless you are competent 

to do the job.

Gutters and downpipes

It is important that all gutters and down pipes 

are kept free from obstructions and blockages. 

Inspect regularly.

12.4 CanExel panels

CanExel prefinished panels are produced from 

wood fibre, resin, and wax fused under pressure.

This engineered wood panelling is highly stable, 

as well as highly resistant to moisture with a 

finish consisting of five coats of baked-on paint 

and a sealer top coat.
The cleaning method recommended is to wash 

down with plenty of clean water and very mild 

detergent.

Содержание Biarritz Lodge 40x13-2 2020

Страница 1: ...CREATING SMILES FOR LIFE Swift Group Owner s Handbook Residential Park Home Issued August 2019 Part No 1725581...

Страница 2: ...Siting 13 General Safety Advice 21 SafeuseofLPG 25 Mainsandelectricitywiring 31 Heatingandthermalproperties 35 Appliances 37 Cooking 39 Blinds 41 Beds 43 General Care 45 Security 59 Winterisation 61...

Страница 3: ...ine A place for all those united in their love of caravanning motorhomes holiday homes and touring in general to share their experiences meet new friends and find out a world of information on how to...

Страница 4: ...es iNote Your attention is drawn to the notice affixed inside the boiler cupboard advising on fire precaution ventilation and what to do in case of a fire Emergency action procedures In the event of g...

Страница 5: ...r any work or modification to your electrical system or appliances Ensure that you understand the working of all electrical switches in your RPH Regularly check that all electrical cable terminal conn...

Страница 6: ...rickle vents refer to the drawings in the technical section of this handbook WARNING Under no circumstances must any ventilator be blocked or obstructed even partially Bunk beds where fitted WARNING U...

Страница 7: ...Home Address Indentification Marking SG Key Number CO Alarm Date of Manufacture Smoke Alarm Date of Manufacture Tel No Supplied and fully inspected before deliv ery by Dealer Dealer Stamp Address Tel...

Страница 8: ...9 Warranties 10 AfterSales 12 Swift Connect Direct 12 WARRANTY AND AFTER SALES SUPPORT...

Страница 9: ...ctural Warranty Period The Structural Warranty covers any defect with the seams of the Home This includes water ingress through any permanently sealed seam joints The Structural Warranty Period means...

Страница 10: ...me which is not approved by Swift Damage caused by Environmental conditions such as UV damage and corrosion Exclusions In addition to the conclusions above the following parts have exclusions Applianc...

Страница 11: ...agents iNote Please remember to quote the chassis number when ordering any items from your Dealer Park operator This can be found on the weight plate inside the boiler cupboard CONNECT DIRECT Warranty...

Страница 12: ...13 Craning 14 Siting 14 Supportingthechassis 15 Jacking 15 Wheelchocks 16 Spreaderplates 16 Anchors 17 Snowloading 17 Chassis specification 18 SITING...

Страница 13: ...for the home placed upon it iNote A Twin unit RPH is produced in two units and should be assembled together on site by professional siting Engineers in accordance with CITO guidelines If the product i...

Страница 14: ...as additional supports and if they are to remain extended should be at least 6mm off the ground 3 3 Supporting the chassis RPHs up to 12 2m long should have a minimum of twelve supports Each chassis l...

Страница 15: ...at other points it is important to check and recheck all support stands to make sure they remain in the correct position Plan to stay safe WARNING No one should be under the RPH whilst it is being li...

Страница 16: ...excess of 48m s 173km h being experienced iNote Each ground anchor should be capable of resisting 10kN in tension The preferred turnbuckle is the type which has an eyelet at both ends as opposed to h...

Страница 17: ...h longitudinal Corner steady maximum extended height of 432mm Corner steadies must not be used to fully support the unit Jockey wheel assembly maximum load that can be applied in a static position is...

Страница 18: ...19 Siting Figure 4 Typical Support and holding down points Twin unit...

Страница 19: ...20...

Страница 20: ...21 Fire precautions 22 Emergency shut off points 23 GENERAL SAFETY ADVICE...

Страница 21: ...ces electrical and LPG systems except by a qualified person WARNING Never use portable cooking or heating equipment other than electric heaters that are not of the direct radiant type as it is a fire...

Страница 22: ...upply point Do not use water on fat or electrical appliances Never go back inside the RPH until a member of the fire service has told you it is safe to do so Fire extinguisher It is recommended that a...

Страница 23: ...24...

Страница 24: ...25 The LPG gas system 26 Gas commissioning notice 26 Using cylinders 26 Gas regulators 27 Low pressure flexible hoses 27 Gas safety 28 SAFE USE OF LPG...

Страница 25: ...ngineers safety check is prominently displayed in the unit for occupants to see If the unit is being used solely for private use other than commissioning these checks are not required by law but it is...

Страница 26: ...inder and the appliance The regulator is precisely set to control the pressure of the supply and must not be adjusted The connection must be by a high pressure flexible hose which shall be as short as...

Страница 27: ...rovals Most of the branded appliances carry their own warranty and after sales support In the event of either being required please follow the directions of the warranty or consult your own supplying...

Страница 28: ...vitally important that you read all instructions and labels before using any appliance and keep them handy for future reference WARNING If in doubt ask Do not place clothes or any other combustible ma...

Страница 29: ...30...

Страница 30: ...31 Mains electricity and wiring 32 Bulbs 33 MAINS ELECTRICITY WIRING...

Страница 31: ...it should now trip off and should be reset simply switching it on again If the unit does not trip off do not use the mains supply until the fault is corrected by consulting either your park owner or a...

Страница 32: ...Both 230v and 12v lighting systems are present in your RPH using a variety of types of ratings wattage across both systems CAUTION It is important to fit the correct rating of light bulbs the voltage...

Страница 33: ...34...

Страница 34: ...35 Centralheatingandhotwatersystem 36 Thermalinsulation 36 Ventilation 36 HEATING THERMAL PROPERTIES...

Страница 35: ...95mm wall insulation in addition to lagged underfloor pipes Radiator valves Thermostatic radiator valves TRV are fitted to all lounge dining and bedroom radiators to control the room temperature 7 3 V...

Страница 36: ...37 APPLIANCES...

Страница 37: ...operate as often resulting in the temperature in the freezer compartment rising If this is for an extended period of time there is a possibility of some of the freezer contents defrosting If the tempe...

Страница 38: ...39 COOKING...

Страница 39: ...l on the hob or to line oven shelves grill pan or allow it to block the oven flue as this creates a fire hazard and hinders circulation When cooking heavy items e g turkeys do not pull the oven shelf...

Страница 40: ...41 BLINDS...

Страница 41: ...ng children can be strangled by loops in pull cords chains tapes and inner cords that operate the blinds To avoid strangulation and entanglement keep cords out of the reach of young children Cords may...

Страница 42: ...43 Pull out sofa bed 44 Bunk beds 44 BEDS...

Страница 43: ...WARNING Care must be taken when using a Pull out bed in close proximity to the space heater 11 2 Bunk beds where fitted WARNING If upper bunks are fitted care shall be taken against the risk of fall o...

Страница 44: ...ructure 46 Blockages 46 CanExel panels 46 Snow precautions 47 Doors and windows 47 Alignment and adjustment of doors 49 Trickle vents 53 Repairs 53 Kitchen and bathroom 53 Cleaning 55 Furnishings 55 S...

Страница 45: ...d be properly planned supervised and carried out by competent people with the skills knowledge and experience to carry out this activity The correct equipment must always be used iNote The roof should...

Страница 46: ...oil or a very light lubricant use sparingly as oil does attract dirt iNote The recommended maintenance is to lubricate every 6 months Minimum recommended cleaning intervals Monthly Frames door and win...

Страница 47: ...h do not impair anti corrosion properties Use cream cleaner for isolated stubborn stains on white UPVC only Apply with a damp cloth using minimal pressure Ensure drainage slots are kept unblocked and...

Страница 48: ...d adjustment of doors If the entrance door becomes misaligned the hinges can be adjusted to bring the door back into alignment The lock keep can also be adjusted to ensure that the lock engages correc...

Страница 49: ...t available Height from lowest Position 7mm Compression from mid position 1 75mm Lateral 5mm Pull back the cover Insert 5mm A F Allen key and turn to move the vent left or right This will increase or...

Страница 50: ...the compression should be adjusted left or right clicks The compression gap should be set to 3mm To lower the the vent turn anti cllockwise and repeat the steps iNote Adjusting the hinges will not co...

Страница 51: ...nd the latch have 20mm vertical movement to aid locking during manufacture transport and siting In addition both the top and bottom keeps and the centre latch have 2mm of lateral adjustment to aid sit...

Страница 52: ...Mixer Valve accurately controls the temperature of water for showering and will maintain the pre set temperatures if the water pressure varies when other appliances are used This significantly reduce...

Страница 53: ...til the water stops flowing Protecting your Thermostatic Mixing Tap In addition to draining down the Thermostatic Mixer Tap in periods of cold and freezing conditions to offer maximum protection it is...

Страница 54: ...th To dry use a soft cloth Stains can be removed using washing up liquid Most bath cleaning powders and liquids will damage the surface of your fitting even the non scratch cleaners Bathroom fittings...

Страница 55: ...or moisture generating appliance Extreme temperature and humidity changes can cause cracking and splitting Some movement may be expected depending on environmental conditions If the air is dry some cr...

Страница 56: ...oking new for years Always vacuum or dust hard floor surfaces before mopping Vinyl floors generally require only warm water for cleaning Vinyl flooring risks being stained by in ground dirt if they ar...

Страница 57: ...58...

Страница 58: ...59 Protecting your RPH and possessions 60 SECURITY...

Страница 59: ...operated with a time switch the light will help deter thieves Ask your park distributor dealer for details on electrical intruder alarms Marking your property with your postcode and house number woul...

Страница 60: ...61 Winterisation 62 Condensation 63 WINTERISATION...

Страница 61: ...er or washing machine is fitted it should be protected from frost damage by carrying out the following instructions 1 Remove electrical power to the dishwasher 2 Turn off the water supply and disconne...

Страница 62: ...w the dew point temperature it is quite normal for condensation to occur on the external walls and any other cold surface When condensation occurs Condensation occurs usually in winter months because...

Страница 63: ...e windows it is important not to block these f It is critical that low level ventilation is not blocked through the use of skirts or decking around the lodge Where such items are fitted and equal amou...

Страница 64: ...65 External dimensions 66 Model names berths and bed sizes 67 TECHNICAL INFORMATION...

Страница 65: ...m 13 2 3 75m 12 4 Vendee Lodge 42x13 2 13 57m 44 6 13 15m 43 2 12 77m 41 11 12 77m 41 11 4 29m 14 1 4 01m 13 2 3 75m 12 4 Whistler Lodge 42x20 2 13 68m 44 10 13 18m 43 3 13 05m 42 10 12 85m 42 2 6 42m...

Страница 66: ...83x0 75m 6 0 x2 6 N A N A Vendee Lodge 42x13 2 4 Plus 2 2 02x1 53m 6 8 x5 0 1 90x0 75m 6 3 x2 6 N A N A Whistler Lodge 42x20 2 4 Plus 2 1 91x1 53m 6 3 x5 0 1 83x0 92m 6 0 x3 0 N A 1 80x1 12m 5 11 x3...

Страница 67: ...Lodge 40 x 13 2 bed layout Window 1500 x 1172 Trickle Vent Window 632 x 1172 Trickle Vent Window 900 x 950 Trickle Vent Window 450 x 620 Trickle Vent Emergency Window 950 x 1172 Trickle Vent Emergency...

Страница 68: ...ndow 1000 x 475 Window 1000 x 475 Trickle Vent Window 866 x 2041 Trickle Vent Emergency Door 866 x 2065 Trickle Vent Emergency Window 590 x 1815 Trickle Vent Emergency Window 590 x 1815 Trickle Vent E...

Страница 69: ...TV GAS C H Window 632 x 972 Trickle Vent Emergency Door 866 x 2063 Trickle Vent Emergency Window 632 x 1172 Trickle Vent Emergency Window 632 x 1172 Trickle Vent Window 632 x 1022 Trickle Vent Emergen...

Страница 70: ...ckle Vent Emergency Window 632 x 1074 Trickle Vent Emergency Window 1000 x 1172 Trickle Vent Trickle Vent Trickle Vent Emergency Window 800 x 1972 Trickle Vent Emergency Window 800 x 1972 Trickle Vent...

Страница 71: ...rickle Vent Emergency Window 632 x 1074 Trickle Vent Emergency Window 1000 x 1172 Trickle Vent Emergency Window 1200 x 880 Trickle Vent Emergency Window 800 x 1972 Trickle Vent Emergency Window 800 x...

Страница 72: ...x 475 Trickle Vent Window 800 x 1172 Trickle Vent Emergency Window 1000 x 1172 Trickle Vent Window 800 x 1172 Trickle Vent Emergency Window 800 x 1972 Trickle Vent Emergency Window 632 x 1022 Trickle...

Страница 73: ...T WATER SUPPLY COLD WATER SUPPLY SINK WASH BASIN TOILET BATHROOM SHOWER HOT AND COLD DRAIN COCKS POSITIONED UNDER BOILER OUTSIDE WASH BASIN TOILET Plumbing typical water system single units WASHING MA...

Страница 74: ...75 BATH EN SUITE BASIN EN SUITE SHOWER SHOWER ROOM BASIN SHOWER Plumbing typical water system twin units Technical info KITCHEN DISHWASHER UTILITY SINK WASHING MACHINE...

Страница 75: ...76 COLD FEED RADIATOR RADIATOR BOILER RADIATOR RADIATOR HOT FEED Plumbing typical heating system single units Technical info...

Страница 76: ...77 RADIATOR RADIATOR RADIATOR RADIATOR RADIATOR RADIATOR RADIATOR BOILER Plumbing typical heating system twin units Technical info...

Страница 77: ...tallation found in a holiday home or park home Various electrical options are available which may be fitted over and above the specification shown Please consult your retailer installer the Swift Grou...

Страница 78: ...79 Single Unit Generic Gas Technical info...

Страница 79: ...80 Single Unit Generic Lighting Technical info...

Страница 80: ...Swift Group Ltd or Sargent Electrical Services if further information is required KEY L1 L4 F1 S1 OUTLET APPLIANCE SWITCH SOCKET OUTLET CORD SWITCH 1G 2G OR PULL OPERATED LIGHT LOCALLY SWITCHED LIGHT...

Страница 81: ...82 Twin Unit Generic Lighting Technical info TWIN LODGE SCHEMATIC 2020...

Страница 82: ...83 Technical info CO AX Schematic LOUNGE OR...

Страница 83: ...windows 47 Drain down procedure 54 E Electricalloungefire heater 38 Electrical Schematics 78 Electricity and fault finding 32 Electrics 31 Emergency exits 68 73 Emergency shut off points 23 Entrance...

Страница 84: ...ng 17 Snow precautions 47 Support and holding down points 18 Supporting the chassis 15 Swift Connect Direct 12 Swift Shield fabric 57 Swift Talk 2 T Tap cleaning 55 Thermal insulation 36 Thermostatic...

Страница 85: ...86 Notes...

Страница 86: ...ILES FOR LIFE Layouts Video Brochure Dealer Social SWIFT GROUP Dunswell Road Cottingham East Yorkshire HU16 4JX Tel 01482 875740 Fax 01482 840082 Email enquiry swiftgroup co uk FIND OUT MORE AT SWIFTG...

Отзывы:

Похожие инструкции для Biarritz Lodge 40x13-2 2020