14
4.2) ELECTRICITY INSTALLATION ENVIRONMENT
4.2.1) Input voltage (to be adjusted at installation)
100V, 110V, 120V, 200V, 220V, 240V, 100V~240V free voltage
4.2.2) Allowed voltage range
Within 10% of the voltage set
4.2.3) Electric capacity and power consumption
3KVA 1.4~1.6KW
4.2.4) Insulation resistance
Over 10M ohms (measured with 500V insulation tester)
4.3) LEVELING THE MACHINE
4.3.1) Leveling the equipment
1) Stand
– If the stand is not installed
If the dedicated stand (optional) is not
attached, use the adjusting bolt to adjust the
back & front and left & right balance of the
machine.
Fixing nut
Adjusting bolts
Check if the input voltage of the machine corresponds with the voltage supply before installing
or operating the machine.
WARNING
1) Make sure to check the voltage supply where the machine will be installed.
2) Install the cable away from the operator
’
’
s work space to prevent accident or injury.
WARNING
The machine must be accurately leveled (especially front-back) to prevent machine from
deformation or needle from moving out of position.
CAUTION