3
F 80A
D
oc: 101516-
GB 1810
As the sound pressure level at the operator’s ears
exceeds
80 dB (A), ear protectors must be used during opera-
tion!
Hand/arm vibrations
The vibration acceleration was measured in accordance
with the ISO 5349 standard during operation on a
graveled surface. The measurement values were
translated into the maximum daily exposure time
for regular usage. For additional information about
vibrations, please confer the regulation AFS 2005:15
from the Swedish Work Environment Authority,
effective July 1st 2005.
Measurement uncertainty ± 0.3 m/s2 in 95% of the
measurements.
Exhaust emissions
F 80Ameet the requirements for exhaust emissions in
acoordance with EU directive 2002/88 Euro2
STANDARDS
Noise
Measurement in accordance with the standard EN 500-
4 Rev. 1:1998, Annex C:
Measurement uncertainty ± 0.5 dB (A) in 95% of the
measurements.
In accordance with the conditions in Directive 2000/14/
EC, Annex VI, the following values are reported:
F 80A
Sound pressure levelat the operator’s
ears, LpA
90dB (A)
LpA
Permitted sound
power level, L
WA
108 dB (A)
Guaranteed sound
power level, L
WA
105 dB (A)
F 80A
Hand/arm-
vibrations, m/s
2
4,6
The maximum daily
exposure time
2,4 h