Swema SwemaCO2 Скачать руководство пользователя страница 7

Notebook display

8. Saved data (Notebook)

To print or control saved measurement series, go to Notebook, see 

4. 

Function keys.

Navigate  between  saved  measurement  series 

with the 

Left & Right arrow keys

, which me-

mory position being shown is indicated with n1, 

n2, n3 etc. directly below the lower measure-

ment (the number is the memory position). The 

measurment shown in ”Notebook” is the average 

value of the saved measurement series. To see 

the Max & Min values, press 

Arrow Up & Ar-

row down

.

Erase saved data

Erase

 makes it possible to delete saved measurement values. Upon 

pressing 

Erase

 the text ”Erase” is shown on the display, to erase the 

entire memory, press  

All.

 Press 

Esc 

to cancel.

It is also possible to erase the last saved measure-

ment value. This is done by navigating to the last 

memory position and pressing 

Erase

, in this case 

three alternatives will show. Press 

Note

 to erase 

the last note or 

All 

to erase the entire memory.  

 

WARNING!

 Only 

All 

can be chosen if the last 

measurement series isn’t selected, which means 

all notes will be erased.

NOTE!

Note

 = Selects the last log.

ALL

 = Selects all logs.

Should  the  last  note  or  the 

entire memory be erased?

6.

Содержание SwemaCO2

Страница 1: ...wema swema se Web page www swema com Contents 1 Introduction 1 2 Start of instrument 2 3 Measurement Mode 2 4 Function keys 3 5 Settings 3 6 Logging 5 7 PC transfer 5 8 Saved data 7 9 Technical data 8...

Страница 2: ...sh whilst also ensuring the fastest possible response time The instrument can display the average value as well as saving and logging values Measurement series can also be transferred to a PC using th...

Страница 3: ...n shows the current measurement in real time Average Max Min The Left arrow average Up arrow max or Down arrow min can be held down respectively to check the average max or min value of a measurement...

Страница 4: ...s 60min 30min 10min 5min and 1min OFF disables the auto shut off completely Unlt SySt Unit system Syst me international SI Uni ted States customary US change of international measurement SI or america...

Страница 5: ...power supply to prevent power loss See also 6 Logging PuP Pump Use the Up and Down arrows to switch between ON OFF It is also possible to switch the pump on and off during a measurement The pump absor...

Страница 6: ...To stop and save a log press All For a brief moment the display will read Notebook with n3 blinking which in this case means that the log was saved as measurement series 3 in notebook The instrument...

Страница 7: ...down Erase saved data Erase makes it possible to delete saved measurement values Upon pressing Erase the text Erase is shown on the display to erase the entire memory press All Press Esc to cancel It...

Страница 8: ...terval CO2 16 seconds for the measured value Two prognostications in between indicated by a on display In stable conditions prognostications equal measured value Barometer Twice per second Log Interva...

Отзывы: