Swegon Connect Скачать руководство пользователя страница 2

Swegon 

Connect

We reserve the right to alter specifications. 

 

20170622

2

Mount and use

DIV

GPS

ANT

PWR

USB

ETH0

ETH1

IN0   IN1  OUT

IN0

IN1

OUT

SIM

WAN

DAT

PWR

USR

POE

SmartFlex

Figure 3: Connecting power

First use

Before you put router into operation, it is necessary to connect 
components that are needed to run your application.

Antenna

Connect the external antenna to the ANT connection on 
the router. Please use the accessory TBRX-1-12, either 1 or 
10 meters, if you need to extend the antenna cable.
The router cannot operate without antenna attached, SIM 
card inserted (pre-mounted) and power supply connected.
The router must be connected to antenna while in operation, 
otherwise damage to the router may occur.
Use SMA connector for antenna connection. Antenna is 
primarily connected by screwing at ANT, see figure 1. An 
additional antenna can be connected at DIV for better 
signal strength.

Network (Ethernet)

The router have by default a standard network port (ETH1) 
for connecting products, see figure 2. If additional connec-
tions are required use the accessory Switch.
Use the router’s other network port (ETH0) when you 
want to connect to a building network or a BMS system. 

* Please contact Swegon for adapting the router to 
a BMS connection.

Power

The supplied transformer must always be used for 
connecting to the power grid. First connect the power 
cable to the router and tighten the connector screws.
Then connect the transformer’s power plug to an 
electrical outlet.

DIV

GPS

ANT

PWR

USB

ETH0

ETH1

IN0   IN1  OUT

IN0

IN1

OUT

SIM

WAN

DAT

PWR

USR

POE

SmartFlex

Figure 2: Connecting network

A: Products/switch or LAN/BMS* to ETH0
B: Products/switch to ETH1

A

B

DIV

GPS

ANT

PWR

USB

ETH0

ETH1

IN0   IN1  OUT

IN0

IN1

OUT

SIM

WAN

DAT

PWR

USR

POE

SmartFlex

Figure 1: Connecting antenna(s)

DIV

ANT

B

A

A: Primary antenna to ANT
B: Additional antenna to DIV (option)

GPS

Содержание Connect

Страница 1: ...wegon Connect Installation instructions Contents of package Router pre mounted SIM card included Power supply Crossover UTP cable External antennas Holder for DIN rail mounting Installation instructions ...

Страница 2: ...tional antenna can be connected at DIV for better signal strength Network Ethernet The router have by default a standard network port ETH1 for connecting products see figure 2 If additional connec tions are required use the accessory Switch Use the router s other network port ETH0 when you want to connect to a building network or a BMS system Please contact Swegon for adapting the router to a BMS ...

Страница 3: ...structions The document can be downloaded from www swegon com Position of the router Mount the router in a position with good mobile communication signal strength If necessary use the extra antenna accessory to ensure sufficient signal strength Mounting router on DIN rail You can mount the router on any standard DIN rail with the supplied DIN holder The DIN holder can be mounted on the bottom or o...

Страница 4: ... 8 Router Figure 9 Standard parts included in package Figure 11 Extension cable for antenna 1 meter or 10 meters accessory Figure 12 Switch accessory Figure 10 Extra antenna accessory Technical data Power supply 230V AC max 10A Frequency 4G 3G GSM 800 900 1800 2100 2600 MHz 900 2100 MHz 850 900 1800 och 1900 MHz Speed LTE HSPA 100 Mbit s down 50 Mbit s up 21 1 Mbit s down 5 76 Mbit s up Support fo...

Отзывы: