23
Critical overtemperature! :
Requires manual reset. Press OK to reset, X to switch off. If cancel is pressed, the
machine will switch off immediately, without performing the 1-minute purging cycle.
Error is detected because:
The temperature in the heat exchanger is above normal temperature.
Possible cause:
Overheat is an indication of unstable electronics or problems with temp sensor connection.
Correct temperature at all times is the most important function in your fog machine. Send
machine to Swefog dealer for qualified service, do not use the machine if the problem has
not been solved completely!
Refer to service manuals for service work. Heat exchanger temperature can be viewed in
the service menu, heater temp.
Possible false alarm cause:
If temperature fluctuates back and forth more than one or a few degrees C, check temp
sensor connection to PCB. Faulty electronics can also cause overtemperature. Consult
Swefog or Swefog dealer, refer to service manuals.
Air line failure! :
Requires manual reset. Press OK to reset, X to switch off. If cancel is pressed, the
machine will switch off immediately, without performing the 1-minute purging cycle.
Error is detected because:
Fluid is detected in the air line tube between air pump heat exchanger, to protect
components, the machine will go to interrupt mode.
Possible cause:
Heat exchanger may be clogged. If this occurs, fluid will be forced in the wrong direction,
through the air line tube. To protect the air pump from damage, and to avoid fluid leakage,
the machine will go to interrupt mode.
Possible false alarm cause:
If air line sensor or air hose is dirty after many hours of use, a false alarm may be triggered.
Send machine to Swefog dealer for qualified service & cleaning. Air line sensor may require
calibration after service.
Do NOT use the machine until the problem has been checked. Refer to service manuals.
Temperature sensor failure! :
Requires manual reset. Press OK to reset, X to switch off. If cancel is pressed, the
machine will switch off immediately, without performing the 1-minute purging cycle.
Error is detected because:
The temperature in the heat exchanger is not responding as expected.
The machine s electronics use an advanced PID technology for precise control of
temperature in the heat exchanger. If the temperature in the heat exchanger is not
responding normally, the machine will go to interrupt mode.
Possible cause:
Bad connection of temperature sensor.
Temperature sensor failure.
Faulty electronics
Correct temperature at all times is the most important function in your fog machine. Send
machine to Swefog dealer for qualified service, do not use the machine if the problem has
not been solved completely!