3.4 Measurements and dimensions
Space requirement:
A distance of 500 mm is required from the boiler where the burner is to be located to the wall (so that the burner can
be removed for cleaning).
A distance of at least 300mm is required from the front edge of the burner to the rear wall of the boiler.
It is also important that there is sufficient space under the burner for the ash that builds up after a week’s operation.
Note that the majority of the ash collects inside the boiler.
TECHNICAL DATA
PB|20
External boiler dimensions (W x H x D)
220 x 250 x 300
Internal firebox dimensions
156 x 200 mm
Combustion efficiency
approx.: 90%
Rated output in max. mode
20 kW
Rated output in half-speed mode
approx.: 10 kW
Voltage
230 VAC
Power consumption (average during
operation)
40 W