SWEBO Bioenergy
Manual pellet burner PB20
Rev no.
Date
Page
PBM1:12
2018-01-22
18 (36)
PS 1
Vers 1.12
Date 2008-10-02
6
Alarm1
6.1
Blank (empty)
6.2
Alarm memory
6.2.1
xxxxxxxxxx
1:Alarm
6.2.3
xxxxxxxxxx
2:Alarm
6.2.3->8
xxxxxxxxxx
x:Alarm
3->8:Alarm
6.3
Buzzer volume
Normal
Off/Low/Normal/High
7
Manuel operation
7.1
Test mode
No
Yes/No (only when shut down)
7.1.1
Start dose
X secs
1-240 s (linked with 2.3)
7.1.2
Dose power stage
Off
Off/1-4 (dose for 15 min combustion, no delay)
7.1.2.x
Feed time
X secs
0.5-20.0 secs (linked with 3.4.x.1, whole range can be adjusted without accessing
service mode)
7.1.3
Electric firing
No
Yes/No (max 5 min, fan 40%)
7.1.4
Fan speed
Off
Off/25-100% (max 5 min)
7.2
Emerg. lighting
No
Yes/No (for “Yes”, combustion with selected power stage & and settings from 7.2.x are low
power)
7.2.1
Feed time
2.0
secs
0.5-20.0 s
7.2.2
Pause time
40 secs
1-300 s
7.2.3
Fan speed
33%
Off/25-100%
7.2.4
Fan time on
20 secs
1-300 s
7.2.5
Fan time off
300
secs
1-600 s