background image

2  |  SmithsEP.co.uk  |  Issue 001 - July 2022

Issue 001 - July 2022  |  SmithsEP.co.uk  |  3

Declaration of conformity

EC Declaration of conformity
We, Smith’s Environmental Products Limited  
1-2 Blackall Industrial Estate 
South Woodham Ferrers 
Chelmsford 
Essex CM3 5UW 
Tel: 01245 324900 Fax: 01245 324422

Declare under sole responsibility that the products:

Product name:  

Ecovector ll Smart LL

Product range:  

LL640, LL1030, LL1390

Conform to the following European  
Union directives: 

Low Voltage Directive 2006/95/EC 
EMC Directive 2004/108/EC 
Pressure Equipment directive 97/23/EC 
Safety Directive 98/37/EC

Standards Comply With The Above Directives.

Safety Directive Standards:

 

 

EN 60335-2-80:2003 + A1:04 in conjunction 
with EN 60335-1:2002 + A11:04 + A1:04 + 
A12:06 + A2:06 With U.K deviations.

EMC Directive Standards:

 

 

EN 55014-1:2000+A1:01+A2:02 
EN 61000-3-2:2000 
EN 61000-3-3:1995+A1:01+A2:05

EMF Standards: 

 

 

EN 50366:2003+A1:06 

This Declaration is made on behalf of Smith’s 
Environmental Products Limited.

 

Salus controller 

The Salus controller independently complies with 
the essential requirements and other relevant 
provisions of Directives 2014/30/EU, 2014/35/EU, 
2014/53/ EU and 2011/65/EU. The full text of the 
EU Declaration of Conformity is available at the 
following internet address: www.saluslegal.com.

Introduction

In the event of items missing or visible damage 
please contact us on 01245 324560.

This heating appliance is intended for 
mounting on a wall at low level. The minimum 
recommended installation height is 100mm from 
the floor. There is no clearance required on either 
side of the heater.

This heater must not be used in bathrooms or 
other high humidity areas.

Ecovector ll Smart LL is designed for use on 
standard two-pipe pumped central heating 
systems where the system hot water is generated 
from either a boiler or renewable sources. This 
product is not suitable for one-pipe heating 
systems. Pipe connections are 15mm.

We recommend the use of full flow isolating 
valves. These valves should be accessible after 
completion of the installation.

Ecovector ll Smart LL is classified as a fixed 
appliance and electrical connection should be via 
a double pole 3A fused spur. The fused spur must 
not be directly above the heater but should be 
accessible after completion of the installation. If 
the pre-wired mains cable is damaged, it must be 
replaced by the manufacturer, its service agent or 
similarly qualified persons. The appliance must be 
earthed.

To avoid possibility of vibration, this product must 
be installed on a flat, even surface.

To comply with Building Regulations Part L (Part J 
in Scotland) this heater is fitted and controlled by 
an integral room thermostat

Please note the guarantee may be invalidated 
if this product is not installed and used in 
accordance with this guide.

Contents

Introduction 2 
Declaration of conformity 

Symbols used in this guide 

3

Important safety and installation instructions 

4

Product dimensions 

6

Wiring diagrams 

6

Product performance 

7

Installation 8
Commissioning 9
Heating Operation 

9

User guide for Wi-Fi thermostat 

10

Getting started - programming  
your thermostat  

12

Fault finding 

16

User Manual 

17

How it works 

18

How to operate 

18

Adding controls to network (UG600) 

20

Fault finding 

22

Accessories 23
Registering your product 

23 

Disposal 23
After sales and spares 

23

Symbols

This manual contains information and 
prescriptions marked by the following symbols.

Ignoring these safety provisions 
marked by the symbol “caution: 
hazard” may endanger the safety 
of people.

Ignoring these safety provisions 
marked by the symbol “caution: 
electricity” may endanger the 
safety of people, as well as the 
integrity of things.

The removal of the screws can 
cause the output of hot fluids 
under high pressure from heating 
system. Drain the system or close 
the isolating valves.

High temperature surface. Take 
utmost care to prevent people 
from getting in contact with the 
hot surfaces of the appliance.

Содержание Smith's Ecovector II LL 1030

Страница 1: ...ly 2022 SmithsEP co uk 1 Issue 001 July 2022 ENGLISH UK IRL SmithsEP co uk Ecovector II Smart LL with Smart Controls Installation commissioning and user manual LL 640 LL 1030 LL 1390 Ecovector II Smar...

Страница 2: ...one pipe heating systems Pipe connections are 15mm We recommend the use of full flow isolating valves These valves should be accessible after completion of the installation Ecovector ll Smart LL is c...

Страница 3: ...orrosive or explosive atmosphere dust vapour or gas EN60335 2 51 For other than intended use 7 Installation The appliance must be mounted in a stable fixed position in a dry well ventilated frost free...

Страница 4: ...T LL 640 0 29 32 38 TBC white n a ECOVECTOR II SMART LL 1030 0 58 35 40 TBC white n a ECOVECTOR II SMART LL 1390 0 83 37 42 TBC white n a Model Heat Output at 80 Heat Output at 75 Heat Output at 70 Lo...

Страница 5: ...onnect the heater three core mains lead to the fused spur 3A in accordance with the instructions provided on the mains lead label The supply wire which is coloured green or green and yellow must be co...

Страница 6: ...Cool Eco selection Programmable schedule Offset Time Date Short press Confirm function Long press 2 sec Activate deactivate standby mode Button functions M M M M M Complete setup instructions for the...

Страница 7: ...g is required to allow fan only function See images 3 and 4 M M 1 2 4 Set the S1 and S2 parameters as shown S1 noFN No Function S2 S2sens External Temperature Sensor Press and hold for 2 seconds M M M...

Страница 8: ...g M M 1 3 M 5 M 4 Factory reset M M M M If you have made an error or need to change your system parameters or want to return to the factory settings please follow steps below By performing this action...

Страница 9: ...at Vent any trapped air from the system with the heating system turned OFF Balance the central heating system if installed on the same circuit as panel radiators and increase the circulating pump spee...

Страница 10: ...can be found at https salus controls com uk product fc600 downloads 1 2 3 4 5 6 13 17 18 16 15 14 7 25 24 23 22 21 20 19 12 10 11 9 8 1 Auto heat cool selection 2 Schedule icon 3 Permanent temporary o...

Страница 11: ...etwork connection see page 15 for factory reset setup guidance before continuing 2 This should be U9 No by pressing the up arrow followed by the tick confirm button See image 1 and 2 M M 3 4 4 3 The n...

Страница 12: ...s Environmental Products LTD reserves the right to alter specification without prior notice Products with this symbol crossed out wheelie bin cannot be disposed as household waste Old electrical and e...

Страница 13: ...sts All products are available nationally from Builders Merchants Plumbers Merchants Heating Equipment Distributors and Kitchen Equipment Distributors In the event of difficulty please contact us or v...

Отзывы: