Panel Intelligent  controls actuators/valves and  automatically regulates fans’ speed depending on the required room tempera-
ture. Fans speed  changes automatically for lower rate, when temperature in a room gets closer to desired one. 
Additional functions – weekly thermostat, availability of BMS communication signals 
Possibility to connect outside temperature sensor NTC, supplied with cable lenght 5 m, max cable length 20 m.  



MULTI 6 Splitter allows to connect and control more fan heaters (up to 6/12 pcs.) and valves with actuators (up to 6/12 pcs.). 
Control of fans and valves is done using COMFORT or INTELLIGENT panel. 
To connect more than 6 fans and valves, it is possible to connect Splitter MULTI 6 with each other (maximum extension of up to 
10 MULTI 6 splitters). In such case, in the first Splitter MULTI 6 there should be connector DS-N left open, in other Splitters 
MULTI 6 (2..10) connector DS-N  must be closed. 

13.

 Electrical connection diagrams

13.1. Connecting Solano units with no automatic control

* The unit set does not consist of: a master switch, a fuse, a feeding cable

SOLANO RANGE



Fan wiring description 

U1 

high

 speed – brown 

U2 

middle

 speed – grey 

U3 

low

 speed – red 

N neutral – blue 
PE protection - yellow/green

13.2. Connecting severalSolano units with COMFORT panel, valves and actuators

One COMFORT panel may regulate up to:
•  3 pcs of Solano Eco 1, 2 or 3
•  2 pcs of Solano MAX
*  The unit set does not consist of: a master switch, a fuse, a feeding cable

HEAT

  - thermostat sends signal for valve/actuator and fan, fan turns off when temperature in room is achieved, valve/actuator closes 

water supply.

FAN

 - function not active, unit will not operate when FAN switch is selected

COOL

 - thermostat sends signal only to fan and the servo of the valve, fan begins operation starting from temperature which is set on 

thermostat (function used to air mixer Solano MIX  or for room ventilation in summer season)

Attention! You can use additional jumper on the contacts 4-5 of COMFORT Panel, in this case you may only use  function of changing 
speed of fan I-II-III and ON/OFF. The thermostat and switches HEAT/FAN/COOL remain not active.
Additional jumper on terminals 4-5 might be applied when for ex different (supplied by user) thermostat is used to control the system.
In that case:
-  motor would be working on set speed
-  thermostat open/close the servo of the valve depending on set temperature

13.3.  Connecting Solano units with panel INTELLIGENT.

Panel Intelligent controls actuators/valves and automatically regulates fans’ speed depending on the required room temperature.  
Fans speed changes automatically for lower rate, when temperature in a room gets closer to desired one. 

Additional functions - weekly thermostat, availability of BMS communication signals 

Possibility to connect outside temperature sensor NTC, supplied with cable lenght 5 m, max cable length 20 m.  

One INTELLIGENT panel may regulate: 
•  up to 2 pcs of Solano Eco.
•  For Solano Eco MAX only 1 pcs
* The unit set does not consist of: a master switch, a fuse, a feeding cable

SOLANO RANGE

Panel Intelligent  controls actuators/valves and  automatically regulates fans’ speed depending on the required room tempera-
ture. Fans speed  changes automatically for lower rate, when temperature in a room gets closer to desired one. 
Additional functions – weekly thermostat, availability of BMS communication signals 
Possibility to connect outside temperature sensor NTC, supplied with cable lenght 5 m, max cable length 20 m.  



MULTI 6 Splitter allows to connect and control more fan heaters (up to 6/12 pcs.) and valves with actuators (up to 6/12 pcs.). 
Control of fans and valves is done using COMFORT or INTELLIGENT panel. 
To connect more than 6 fans and valves, it is possible to connect Splitter MULTI 6 with each other (maximum extension of up to 
10 MULTI 6 splitters). In such case, in the first Splitter MULTI 6 there should be connector DS-N left open, in other Splitters 
MULTI 6 (2..10) connector DS-N  must be closed. 

Fan wiring description
U1    high speed 

brown

U2    middle speed 

grey

U3    low speed 

red

N      neutral 

blue

PE    protection - yellow/green

13.4.  Splitter MULTI 6 - control up to 6 pieces of Solano Eco/Solano Eco MAX from one COMFORT or INTELLIGENT Panel

MULTI 6 Splitter allows to connect and control more fan heaters (up to 6 pcs.) and valves with actuators (up to 6 pcs.). Control of fans 
and valves is done using COMFORT or INTELLIGENT panel. 

To connect more than 6 fans and valves, it is possible to connect Splitter MULTI 6 with each other (maximum extension of up to 10 
MULTI 6 splitters). In such case, in the first Splitter MULTI 6 there should be connector DS-N left open, in other Splitters MULTI 6 (2..10) 
connector DS-N must be closed. 

Содержание Eco 1

Страница 1: ...Issue 002 November 2022 SmithsEP co uk 1 Installation commissioning and user manual Unit heater Solano Eco Issue 002 November 2022 ENGLISH UK IRL SmithsEP co uk...

Страница 2: ...airflow range m 24 21 19 26 25 23 13 16 Diameter of connection nozzles inches 3 4 3 4 Power supply V Hz A 230 50 1 08A 230 50 2 2A 230 50 1 08A 230 50 2 2A Motor power W 250 520 250 520 Motor speed rp...

Страница 3: ...delivery In the absence of any element please advise Smith s immediately Prior to any installation procedures take the following aspects into consideration easy access for maintenance works access to...

Страница 4: ...t the automatic control depending on the option chosen Any and all damages incurred as a result of the aforementioned causes are not provided with the Guar antee and the user will be charged with any...

Страница 5: ...8 0 8 0 7 0 7 0 6 1 0 0 9 0 9 0 8 0 7 0 9 0 8 0 8 0 7 0 7 pressure drop kPa 5 4 4 7 4 0 3 4 2 8 6 9 6 1 5 3 4 6 4 0 5 2 4 7 4 3 3 9 3 5 Heater Eco 2 12 Technical data inlet outlet water temperature wa...

Страница 6: ...0 9 0 9 0 8 0 7 1 2 1 1 1 0 0 9 0 9 1 0 1 0 0 9 0 9 0 8 pressure drop kPa 7 0 6 1 5 3 4 5 3 8 8 8 7 9 6 9 6 1 5 3 6 7 6 1 5 6 5 1 4 6 Heater Eco 3 inlet outlet water temperature water 50 30 C water 60...

Страница 7: ...1 8 1 7 1 5 1 4 1 7 1 6 1 5 1 4 1 3 pressure drop kPa 13 2 11 3 9 6 8 1 6 7 17 5 15 3 13 3 11 5 9 8 12 6 11 4 10 2 9 2 8 1 Heater Eco MAX 2 inlet outlet water temperature water 50 30 C water 60 40 C...

Страница 8: ...n for ex different supplied by user thermostat is used to control the system In that case motor would be working on set speed thermostat open close the servo of the valve depending on set temperature...

Страница 9: ...okada ustawie SOLANO RANGE 1 Power supply 230VAC 50Hz 2 Temperature setting range 5 C 40 C 3 Temperature working range 10 C 60 C 4 IP class 20 5 Temperature sensor Internal external NTC optional Pr dk...

Страница 10: ...more details please visit our website SmithsEP co uk Disposal As part of the policy of continuous product improvement Smith s Environmental Products LTD reserves the right to alter specification witho...

Страница 11: ...o offer any help and guidance that you might need Stockists All products are available nationally from Builders Merchants Plumbers Merchants Heating Equipment Distributors and Kitchen Equipment Distri...

Отзывы: