background image

Installation Instructions and User Guide

Models Covered: 

 

C58102 & C58117

Please keep this booklet for future reference.

Installer, when you have read these instructions please ensure you leave them with the user.

Содержание C58102

Страница 1: ...stallation Instructions and User Guide Models Covered C58102 C58117 Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user ...

Страница 2: ...s 4 Fit the bracket using the fixings supplied 5 Connect the hose to the tap body and handset 6 Fully open both valves letting them run for a few minutes to flush out the system Check all joints and connections for leaks Working Pressure Range Min 0 2 bar Max 5 0 bar Maximum Static Pressure 10 bar BS 6700 recommends the temperature of stored water should never exceed 65 C A stored water temperatur...

Страница 3: ... the steps in reverse Turn on the water supply and check connections for any leaks Symptom Cause Remedy No flow or low flow rate Partially closed isolation valve Open isolation valve Instantaneous water heater cycles on and off as flow rate or pressure is too low Increase water flow rate or pressure through system Water pressure is below the required minimum Refer to specification for minimum pres...

Страница 4: ...ect to wear and tear Mechanical parts subject to wear and tear are covered by a 12 month guarantee The chrome plated finish is covered under the same guarantee period of 5 years but is subject to the cleaning instructions being followed The guarantee is not applicable where the product is fitted contrary to the conditions in the fitting instructions Misuse and accidental damage to the product are ...

Отзывы: