background image

r000 

r000-r255,Red color dimming.

 

G000 

G000-G255,Green color dimming.

 

b000 

b000-b255,Blue color dimming.

 

3 Channel instruction 

7 Channel instruction 

NO 

Value 

Function 

CH1 

0-255

Master dimming.

 

CH2 

0-255

Master strobe.

 

CH3 

0-255

Function selection,0-50: 7 Channel control,51-100:jump 
effect,101-150:gradual 

change 

effect,151-200:pulse 

change effect,201-255:sound active.

 

CH4 

0-255

Function speed.

 

CH5 

0-255

Red color dimming.

 

CH6 

0-255

Green color dimming.

 

CH7 

0-255

Blue color dimming.

 

Cleaning 

Due to fog residue, smoke, and dust cleaning the internal and external optical lenses 

must be carried out periodically to optimize light output. 

1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.

2. Clean the external optics with glass cleaner and a soft cloth every 20 days.

3. Always be sure to dry all parts completely before plugging the unit back in.

Cleaning  frequency  depends  on  the  environment  in  which  the  fixture  operates  (i.e. 

smoke, fog residue, dust, dew). 

Trouble Shooting 

Listed below are a few common problems the user may encounter, with solutions. 

A001 

001—512

,7CH address code. 

d001 

001—512

,3CH address code. 

tb00 

01—99

,7 Color jump effect. 

Zb00 

01—99

,

 Color pulse change and gradual change effect.

 

ZH00 

01—99

,

 

Color combination effect change. 

JLbE 

01—99

,

 

Sound active. 

No 

Value

 

  Function

 

CH1 

0-255

R dimming. 

CH2 

0-255

G dimming. 

CH3 

0-255

B dimming. 

Содержание LT-Par64

Страница 1: ...er PLEASE recycle the shipping carton when ever possible General Instructions To optimize the performance of this product please read these operating instructions carefully to familiarize you with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Feature...

Страница 2: ...device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product outdoors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or agai...

Страница 3: ...be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew Trouble ...

Страница 4: ...nnected Unit does not respond to sound 1 Quiet or high pitched sounds will not activate the unit If problems are not resolved contact your dealer for service Specifications Model LT LP 36P Working Position Any safe working position Voltage 90 240V 50H 60Hz Colors RGB Color Mixing LED 36PCS 3W RGB Len s angle 25 degree Channel 3 7ch selectable Gross Weight 4 0 Kgs Dimensions 240 H x 240 W x 310 L m...

Отзывы: