Swagelok Changeover SCO Скачать руководство пользователя страница 19

SCO User Manual

19

Troubleshooting

Symptom

Cause

Remedy

HP inlet pressure gauge 
shows no (or low) 
pressure.

There is an obstruction upstream 
of the SCO.

Check that flow is passing through the inlet subassemblies 
by checking inlet vent needle/bleed valve.

There is no process pressure.

Check that the supply line is pressurized.

The inlet vent valve is open.

Close the vent valve.

LP outlet gauge shows 
no (or low) pressure.

Bottles are empty.

Change bottles.

Outlet regulator set to zero outlet 
pressure.

Adjust regulator outlet pressure.

Relief valve is set at too low of a 
pressure.

Check relief valve set point and outlet regulator pressure 
setting. If relief valve needs to be reset, contact your 
authorized Swagelok sales and service center.

Outlet regulator damaged.

Inspect, repair, and/or replace regulator.

LP outlet gauge shows 
high pressure.

Regulator creep.

Inspect, repair, and/or replace regulator.

Pressure gauge is damaged.

Inspect, repair, and/or replace gauge.

Additional pressure source 
downstream in system.

Identify and correct system malfunctions.

Changeover function not 
operating properly.

Changeover handle assembly has 
slipped.

Check alignment marks on changeover handle hub and 
shaft assembly. Refer to maintenance section.

Secondary source 
pressure is dropping/ 
both sources draining 
simultaneously.

Regulator creep.

Inspect, repair, and/or replace regulator.

Both source bottle pressures are 
below the changeover point.

Replace both source bottles.

Inlet vent valves leaking.

Inspect, repair, and/or replace inlet vent valve.

Inlet vent valve open.

Close inlet vent valves.

Relief valve is relieving 
pressure.

Incorrect relief valve set point.

Check relief valve set point. If relief valve needs to be reset, 
contact your authorized Swagelok sales and service center.

Regulator creep.

Inspect, repair, and/or replace regulator.

Additional pressure source 
downstream in system.

Identify and correct system malfunctions.

For any symptoms not identified in the above table, please contact your authorized Swagelok sales and service center.

Содержание Changeover SCO

Страница 1: ...Swagelok Changeover SCO User Manual...

Страница 2: ...SCO User Manual 2 Content SCO User Manual Introduction 3 Configurations 4 Mounting 6 Installation 7 System Startup 8 Operation 9 Maintenance 10 Reference Instruction Documents 18 Troubleshooting 19...

Страница 3: ...y gas control system pre engineered for applications where the continuous supply of gas is critical When one source is depleted below a selected changeover pressure the continuous gas delivery system...

Страница 4: ...l information Configuration 1 No Outlet Regulator Relief Valve Gauge and Noncaptured Inlet Valve Changeover Lever Handle Relief Valve Outlet Isolation Valve Outlet Gauge PI Inlet Gauges PI Inlet 1 pri...

Страница 5: ...Regulator Relief Valve Gauge and Captured Inlet Vent Relief Valve Outlet Gauge PI Outlet Isolation Valve Inlet Gauges PI Captured Inlet Vent Valves Inlet 1 primary source Inlet 2 secondary source Outl...

Страница 6: ...teners Approximate weight of the SCO is 20 4 lb 9 3 kg Dimensions Dimensions in inches millimeters are for reference only and are subject to change NOTE Weight will vary based on options ordered 13 6...

Страница 7: ...et vent systems a bleed valve is used to vent to atmosphere CAUTION Position the bleed valve so that system fluid is directed away from operating personnel Always open bleed valves slowly Operating pe...

Страница 8: ...elief valves conform to them Country Regional standard relief valves are to be maintained in accordance with local rules and regulations of the country in which they are installed CAUTION Swagelok pro...

Страница 9: ...lever handle from the upward position 12 o clock to the downward position 6 o clock Note The primary gas source changeover regulator is set to a slightly higher outlet pressure than the opposing secon...

Страница 10: ...regulators to their respective mounting brackets High Pressure HP Ports Are Shown in Red Low Pressure Ports Are Shown in Blue The Regulators Are E Pattern Changeover Handle Assembly To decouple the c...

Страница 11: ...stablish the requested changeover pressure from the ordering number 2 Use the 7 mm hex on the end of the stem to set the regulator to the desired changeover pressure 3 For the LH regulator only once t...

Страница 12: ...nd 5 32 in 4 mm before contacting the regulator body The changeover lever handle must be pointed toward the top of the panel 6 Screw the regulator handle lock nut M10 x 1 mm back onto the regulator st...

Страница 13: ...to the main panel 16 Thread the shaft onto the regulator stem to achieve engagement of the shaft and hub ensuring the regulator stem does not rotate The shaft should extend past the set screw hole 17...

Страница 14: ...the 12 o clock position The handle should always be pointing to the top of the panel 12 o clock 20 Mark the hub and shaft Cycle the changeover valve several times to ensure smooth operation Check to...

Страница 15: ...w heads are recessed on the rear of the bracket so it can assemble to the main panel flush and without interference To remove the regulator the 1 4 in or 6 mm button head cap screws must be loosened t...

Страница 16: ...nel first unscrew the 1 4 in or 6 mm button head cap screws to remove the bracket from the main panel The 1 4 in or 6 mm Swagelok tube fittings can then be loosened and the valve and bracket are remov...

Страница 17: ...Area Flowmeters G Series and M Series MS 02 346 KPR series regulator Pressure Regulators K Series MS 02 230 D series needle valve Nonrotating Stem Needle Valves D Series MS 01 42 Ball valve 40G or 40...

Страница 18: ...xternally Adjustable Relief Valve Maintenance Instructions MS CRD 0013 Service Instructions CH Series Check Valve MS CRD 0025 CA and CPA Series Check Valve Cracking Pressure Adjustment MS CRD 0047 D S...

Страница 19: ...s damaged Inspect repair and or replace gauge Additional pressure source downstream in system Identify and correct system malfunctions Changeover function not operating properly Changeover handle asse...

Страница 20: ...designer and user Warranty Information Swagelok products are backed by The Swagelok Limited Lifetime Warranty For a copy visit swagelok com or contact your authorized Swagelok sales and service center...

Отзывы: