11.  Set RH regulator by following steps 1 through 4. It is imperative that once the set point is reached it is held by ensuring the stem 

does not move. Do NOT add half a turn increase or adjust the set point in any way on the RH regulator, as doing so will result in 
gas being drawn from both bottles. It may be easier to do this with the LH regulator removed from the back plate.

12.  Fit the M10 × 1 mm nut onto the stem, ensuring the stem does not move. Tighten nut all the way to the body. Then turn nut 

slightly to ensure the stem will not move when the shaft is fitted. Do not overtighten the nut.

13.  Screw the 

machined shaft

 onto the regulator 

stem

, ensuring the stem does not rotate.

5.  Slowly and without changing the set pressure, screw on the machined changeover 

SCO hub

 to the LH regulator. Stop the 

hub around 5/32 in. (4 mm) before contacting the regulator body. The 

changeover lever handle

 must be pointed toward the 

top of the panel. 

6.  Screw the regulator handle lock nut (

M10

 x 1 mm) back onto the regulator stem. 

7.  Tighten the 

M10

 nut all the way down inside the SCO hub. Tighten while holding the 

changeover lever handle

 in place 

pointed towards the top of the panel. The 

changeover lever handle

 must point towards the outlet of the panel at all times. 

8.  The regulator set point should remain unchanged after tightening (a slight change 0.5 bar/7 psig is acceptable). 

Visually verify that the stem has not rotated by checking the location of the mark placed in step 4. 

9.  Ensure the 

SCO hub

 rotates through its full movement of 180 degrees. The handle should rotate from 12 o’clock to 6 o’clock 

freely without the 

SCO hub

 hitting the body or slipping on the shaft. 

10.  The LH regulator is now set. 

M6 × 1 Bolt

1/4 in. × 20 Bolt

M10 Retaining Unit 

From KPR Handle

SCO Hub

Gap Between Hub and Cap

Changeover 

Lever Handle

Machined Shaft

Stem

Содержание Changeover SCO

Страница 1: ...Swagelok Changeover SCO User Manual...

Страница 2: ...SCO User Manual 2 Content SCO User Manual Introduction 3 Configurations 4 Mounting 6 Installation 7 System Startup 8 Operation 9 Maintenance 10 Reference Instruction Documents 18 Troubleshooting 19...

Страница 3: ...y gas control system pre engineered for applications where the continuous supply of gas is critical When one source is depleted below a selected changeover pressure the continuous gas delivery system...

Страница 4: ...l information Configuration 1 No Outlet Regulator Relief Valve Gauge and Noncaptured Inlet Valve Changeover Lever Handle Relief Valve Outlet Isolation Valve Outlet Gauge PI Inlet Gauges PI Inlet 1 pri...

Страница 5: ...Regulator Relief Valve Gauge and Captured Inlet Vent Relief Valve Outlet Gauge PI Outlet Isolation Valve Inlet Gauges PI Captured Inlet Vent Valves Inlet 1 primary source Inlet 2 secondary source Outl...

Страница 6: ...teners Approximate weight of the SCO is 20 4 lb 9 3 kg Dimensions Dimensions in inches millimeters are for reference only and are subject to change NOTE Weight will vary based on options ordered 13 6...

Страница 7: ...et vent systems a bleed valve is used to vent to atmosphere CAUTION Position the bleed valve so that system fluid is directed away from operating personnel Always open bleed valves slowly Operating pe...

Страница 8: ...elief valves conform to them Country Regional standard relief valves are to be maintained in accordance with local rules and regulations of the country in which they are installed CAUTION Swagelok pro...

Страница 9: ...lever handle from the upward position 12 o clock to the downward position 6 o clock Note The primary gas source changeover regulator is set to a slightly higher outlet pressure than the opposing secon...

Страница 10: ...regulators to their respective mounting brackets High Pressure HP Ports Are Shown in Red Low Pressure Ports Are Shown in Blue The Regulators Are E Pattern Changeover Handle Assembly To decouple the c...

Страница 11: ...stablish the requested changeover pressure from the ordering number 2 Use the 7 mm hex on the end of the stem to set the regulator to the desired changeover pressure 3 For the LH regulator only once t...

Страница 12: ...nd 5 32 in 4 mm before contacting the regulator body The changeover lever handle must be pointed toward the top of the panel 6 Screw the regulator handle lock nut M10 x 1 mm back onto the regulator st...

Страница 13: ...to the main panel 16 Thread the shaft onto the regulator stem to achieve engagement of the shaft and hub ensuring the regulator stem does not rotate The shaft should extend past the set screw hole 17...

Страница 14: ...the 12 o clock position The handle should always be pointing to the top of the panel 12 o clock 20 Mark the hub and shaft Cycle the changeover valve several times to ensure smooth operation Check to...

Страница 15: ...w heads are recessed on the rear of the bracket so it can assemble to the main panel flush and without interference To remove the regulator the 1 4 in or 6 mm button head cap screws must be loosened t...

Страница 16: ...nel first unscrew the 1 4 in or 6 mm button head cap screws to remove the bracket from the main panel The 1 4 in or 6 mm Swagelok tube fittings can then be loosened and the valve and bracket are remov...

Страница 17: ...Area Flowmeters G Series and M Series MS 02 346 KPR series regulator Pressure Regulators K Series MS 02 230 D series needle valve Nonrotating Stem Needle Valves D Series MS 01 42 Ball valve 40G or 40...

Страница 18: ...xternally Adjustable Relief Valve Maintenance Instructions MS CRD 0013 Service Instructions CH Series Check Valve MS CRD 0025 CA and CPA Series Check Valve Cracking Pressure Adjustment MS CRD 0047 D S...

Страница 19: ...s damaged Inspect repair and or replace gauge Additional pressure source downstream in system Identify and correct system malfunctions Changeover function not operating properly Changeover handle asse...

Страница 20: ...designer and user Warranty Information Swagelok products are backed by The Swagelok Limited Lifetime Warranty For a copy visit swagelok com or contact your authorized Swagelok sales and service center...

Отзывы: