background image

5

Fig. 7 Body Die Removal / Installation

Gauge 

will not

 enter

Gauge 

will

 enter

Fig. 6 Using the MHSU Gap Inspection Gauge

Step 5

Step 6

Step 2

Step 1

Lock 

ring

Die 

head

Hydraulic 

Housing

  3.  Select the replacement 

die head

 suitable for the 

16FK MHSU.

  4.   Check  the 

die head

 piston for movement by 

depressing the piston before inserting the die 
head into the 

hydraulic housing

.

  5.  Install the selected 

die head

 into the 

hydraulic 

housing,

 and align the two notches on the die 

head with the two 

locating pins

 on the hydraulic 

housing. See Fig. 8.

Gauging Instructions

Position the Swagelok 16FK gap inspection gauge 
adjacent to the gap between the nut and body hex. 
See Fig. 6.

■  

If the gauge 

will not

 enter the gap, 

the fitting is 

sufficiently tightened.

  If the gauge 

will

 enter the gap, 

additional 

tightening is required.

Die Head Replacement

  1.  Unthread and remove the threaded 

lock ring

 

from the 

hydraulic housing

.

  2.  Remove the previously installed 

die head

 from 

the 

hydraulic housing

. See Fig. 7. 

  6.  Reinstall the threaded 

lock ring

 into the 

hydraulic housing

Note:  Visually verify that the threaded lock ring 

is threaded until it is bottomed out against 
the face of the hydraulic housing.  
See Fig. 9.

Locating pin

Notch

Notch

Locating pin

Fig. 8 Die Head Alignment

Fig. 9

Hydraulic housing

Bottomed

Отзывы: