-7-
5.3.
SVT-4
WIRING CONNECTION
1. Red
2. Blue
3. Yellow
4. White
4-Video
1-Audio
2-GND
3-V+
5.3.1
Indoor Monitor
1. Red
2. Blue
3. Yellow
4. White
1. Red
2. Blue
3. Yellow
4. White
NOTE:
Do not remove any of the jumpers from the back of the indoor
monitors.
By removing a jumper or changing its position, some of the features may
not work properly.
5.3.2
Outdoor Station
Upper module:
CN1
:
Must remain connected to CN10 port on the lower module.
Lower module:
PWR:
Connect a SVT-MF4 PS17 Power supply.
J3:
Use this port to connect a door lock.
The door lock is limited to 14.5V, 200mA.
Must use an additional power supply for the door lock. Ensure the power supply is
compatible with the door lock specifications.
The J3 output is also DRY contact (NO/COM/NC).
CN10:
Must remain connected to J1 port on the upper module.
CN22:
Reserved port.
JP1:
Remove the black jumper if a access control unit is connected to the outdoor station
(SVT-3100 / SVT-4100 / SVT-5100 Access Control System only).
J1:
Connect the access control unit (SVT-3100 / SVT-4100 / SVT-5100 Access Control
System only).
CN3:
Reserved port.
CN2:
Connect to the indoor monitor (Upper call button
)
CN1:
Connect to the indoor monitor (Lower call button
)
CN1: Connect to the first Outdoor Station
CN2: Connect to the second Outdoor Station
Middle
module:
PWR
:
Reserved port.
J4:
Use this port to connect an exit button (Use red/black wire with 2 connections).
J1:
Must remain connected to J1 port on lower module.
J3:
Reserved port.