background image

-1

4

-

8.How to set up the 

u

ser 

c

odes

SVT-

MF4 Outdoor Station 

D

 

requires the SVT Remote 

Control for programming.

SVT 

REMOTE

 

CONTROL

 works as a remote access control

It is 

required

 to program the SVT-4 Outdoor Station 

D

 

settings

,

 as registering and deleting fingerprints, unlocking 

time and fingerprint security level.

SVT REMOTE 

CONTROL

 

Use two AAA alkaline batteries

Sensor 

working 

distance: 

+/- 

20cm  

Modify access control password

Press * and #, enter XXXX(the administration password) and #. A Di
sound indicates in the setting mode.  Press  *  to  return  to  standby
mode. (No operation in 20 seconds  will  return  automatically).  The
factory default password is 4567.

In the setting mode

In the setting mode:

Press 8 with a Di sound,  then enter new 4-digits  password (XXXX)
and #. After a Di sound, re-enter  the  new 4-digit password and #. If
two Di sounds  is  heard,  it  means  the  modification  is  successful.
If  enter  different  passwords  twice,  continued   Di...   sound   will  be
heard, the modification of password fails. Please modify again.

Press * to return to standby mode. 

If  forget  password,  turn  on  the  power  again  and  press  #  for 3

seconds. If Bi is heard, default  password is restored.  

Содержание SVT-MF4

Страница 1: ...SVT MF4 Outdoor Station D User Manual Please read this user manual prior to installing the system and keep it well for future use ...

Страница 2: ...m with two entrances 6 6 Cable Requirements 10 7 User Instructions 11 5 3 SVT 4 Wiring Connection 7 7 1 Visitor calls 11 7 2 Monitor 12 7 3 Intercom 13 4 1 Mounting without the Rain Guard 3 4 2 Mounting with the Rain Guard 4 4 3 Mounting the Indoor Monitor 4 5 3 1 Indoor Station 7 5 3 2 Outdoor Station 7 8 8 How to set up User Codes 14 15 5 3 3 Electric door lock connection 9 ...

Страница 3: ...utton Built in microphone Description 1 Built in microphone 2 Monitor button 3 Intercom button 4 Door unlock button 5 Talk button 6 TFT 7 color display 7 Built in speaker 8 Talking Ring volume 9 Brightness 10 Contrast Status light Calling in red light Monitoring Talking blue light 6 Name plate 7 Card Reader ...

Страница 4: ... 2 2 Terminal Descriptions ...

Страница 5: ...wer Supply Must be used according to lock Unlocking time 01 99 seconds Communication duration 120s Communication transmission 2 way communication Working temperature 4 F to 131 F 20 C to 55 C INDOOR MONITOR Voltage DC 14 5V Communication duration 120s Communication transmission 2 way communication Working temperature 14 F to 131 F 10 C to 55 C 4 1 MOUNTING WITHOUT THE RAIN GUARD ...

Страница 6: ... 4 Screw anchors Screws Screws fix with rain cover Rain cover Wall hole 4 2 MOUNTING WITH THE RAIN GUARD 4 3 MOUNTING THE INDOOR MONITOR ...

Страница 7: ... 5 5 1 SVT MF4 SYSTEM WITH ONE ENTRANCE System Wiring and Connections 5 ...

Страница 8: ... 6 5 2 SVT MF4 SYSTEM WITH TWO ENTRANCES ...

Страница 9: ...k Ensure the power supply is compatible with the door lock specifications The J3 output is also DRY contact NO COM NC CN10 Must remain connected to J1 port on the upper module CN22 Reserved port JP1 Remove the black jumper if a access control unit is connected to the outdoor station SVT 3100 SVT 4100 SVT 5100 Access Control System only J1 Connect the access control unit SVT 3100 SVT 4100 SVT 5100 ...

Страница 10: ... 8 ...

Страница 11: ...tion 1 Use the port J3 of the lower module to connect a door lock 2 The door lock is limited to 14 5V 120mA 3 Must use an additional power supply for the door lock Ensure the power supply is compatible with the door lock specifications ...

Страница 12: ... reach 230 feet 70 meters 30 feet 10 meters NOTE 1 The system expands to a maximum of 2 outdoor stations and 4 indoor monitors 2 Each indoor monitor requires its own power supply 14 5V 1 3A 3 We recommend soldering the wires together to ensure a good connection Do not use wire nuts 10 4 For long runs typically longer then 90ft we recommend using coax cable for the video function ...

Страница 13: ... shown on the monitor 7 1 Visitor calls Check After pressing the unlocked button the indoor monitor still displays the image from the front door camera End the call Talk begins Open the lock The talk time is up to 2 minutes Press the TALK button or hang up the handset The visitor presses the call button on outdoor station 1 Ring Ring The visitor presses the call button on outdoor station 2 7 User ...

Страница 14: ...ain indoor monitor to extension indoor monitor Any indoor monitor press button or pick up the handset to talk with the outdoor station Press twice Press once The indicator light of Door 1 is on The indicator light of Door 2 is on End the monitor Press the monitor button Monitor outdoor station 1 Monitor outdoor station 2 Press the talk button Press the talk button Monitor the outdoor station Press...

Страница 15: ...button or hang upbutton or hang up the handsetthe handset Talk begins Any indoor monitor presses button or pickup the handsetto talk 7 3 Intercom In the standby mode press intercom button in any indoor monitor During the talking any indoor monitor presses the intercom button ...

Страница 16: ...sword and A Di sound indicates in the setting mode Press to return to standby mode No operation in 20 seconds will return automatically The factory default password is 4567 In the setting mode In the setting mode Press 8 with a Di sound then enter new 4 digits password XXXX and After a Di sound re enter the new 4 digit password and If two Di sounds is heard it means the modification is successful ...

Страница 17: ...mode No operation in 30 seconds will return automatically In the setting mode Press 1 Di sound indicates it is in the adding user card mode Enter the last 6 digits of a new card number If Di sound is heard it indicates the adding is successful Or swipe the new card instead of adding the card numbers If a Di sound and another Di sound are heard it indicates the adding is successful Continuous batch...

Страница 18: ...ing time Delete all user cards In the setting mode Press 3 a Di sound is heard Enter 6 digits 4 digits building No and 2 digits machine number press with a Di sound It indicates the setting is successful Press to return to standby mode No operation in 30 seconds will return automatically In the setting mode Press 9 with a Di sound heard And then press 9 two short Di sounds can be heard After it st...

Страница 19: ......

Страница 20: ...The design and specifications of this user manual can be changed without any notification to the user All copyright and interpretation rights are reserved to SVT Innovations Inc ...

Отзывы: