Calling System
Operating Instructions (
D -
GB)
Please read carefully!
T
hese operating instructions form an integral part of this product and contain important information on how to commission, install and
operate it. They must be taken into consideration and given to the end user or other third party when the installer hands over the
product. These operating instructions must be retained for future reference.
Damage resulting from abuse or misuse is not covered by warranty. The manufacturer accepts no warranty for consequential losses
that may result directly or indirectly from use of this equipment. Any changes or modifications not expressly approved by the party
responsible for compliance could void the user´s authority to operate the equipment.
The product meets the requirements of the current European and national guidelines for electromagnetic compatibility. Conformity has
been established and the relevant statements and documents have been deposited at the manufacturer.
It should be noted that for applications that could put human life at risk, by using radio connection there is always
present a potential hazard due to extraneous disturbances.
The Operating Instructions need to be followed at all times.
1
Mode of Operation
Minicall12 verifies coded radio frequency signals sent by corresponding transmitters and operates display and signalisation on receipt
of a correct signal. The Minicall-12 is not a medical device.
It must be noted that for applications or installations involving wireless transmission and which could have an influence to safety of man
or machine there may be a risk of unforeseen operation from extraneous uncontrolled radio signals.
2
Description
Minicall 12 is a self observing calling system with up to 12 calling lines. For each calling line (channel) a maximum of 5 transmitters
may be programmed. So, up to 60 transmitters (MT-12 and WT-12) may be used within this system.
Once a call is initiated at transmitters side, the Minicall12 will signalize optically and acoustically the corresponding channel and will
transmit this call also to portable receivers (R-12). The display of portable receivers will show the channel Number (1..12). A maximum
of 5 portable receivers may be programmed.
For the additional display of calls an optional signaler (SG-12) can be used on each channel. In addition to the function as a room
signal light, digital outputs can also be used to control external signals.
An active call may be cancelled by pressing the corresponding push button at the Minicall12 or by confirming the call with a portable
receiver. If more than 1 call is active, the portable receivers will show them one after the other and only the call appearing in the display
may be confirmed by pressing the push button “OK” twice.
If there is to realize a bigger range of operation, up to 5 repeaters may be used.
For any incoming call there is a potential free contact inside the housing which will switch for 1 second (up to 15 seconds selectable).
This is for external signalisation devices if needed.
An interruption of radio communication to a transmitter is shown by flashing periodically twice the channel LED and a short BEEP. Just
press the push button to stop signalisation if the problem is known.
Low battery of any transmitter is signalized by flashing 5 times periodically the corresponding cannel LED.
Summary of signalisation in normal operation mode:
„LED ON” is permanently on
AC-adaptor (Supply) is connected
„LED ON” flashes once a second
Minicall12 is running on battery supply (AC-adaptor missing)
„LED DATA” flashes shortly
signalizes radio communication
„LED DATA” flashes shortly twice
Batteries of Minicall12 are empty or taken off
„Channel LED” (1…12) is permanently on
call (1…12) has been received
„Channel LED” (1…12) flashes periodically twice
radio communication to the corresponding transmitter fails
“Channel LED” (1…12) flashes 5 times periodically
battery capacity of the corresponding transmitter is low
4
Installation and functional check
4.1
Minicall12
Just connect the AC-adaptor and you will hear a starting melody and the green “LED ON” will turn on. The yellow “LED DATA” flashes
about twice a second. This will show, that the battery supply is still not activated. Keep this state until later.
4.2
TeachIn
(if system is ordered including CG-Service, continue at 4.4)
Transmitter
MT-12 / WT-12
Push
button
Portable Receiver
R-12
Push
button
Repeater
RT-12
Push
button
Signaler
SG-12
Push
button
Channel 1
1
Channel 1
1 + 2
Channel 1
7 + 8
Channel 1
1
Channel 2
2
Channel 2
2 + 3
Channel 2
8 + 9
Channel 2
2
Channel 3
3
Channel 3
3 + 4
Channel 3
9 + 10
Channel 3
3
Channel 4
4
Channel 4
4 + 5
Channel 4
10 + 11
Channel 4
4
Channel 5
5
Channel 5
5 + 6
Channel 5
11 + 12
Channel 5
5
Channel 6
6
Channel 6
6
Channel 7
7
Channel 7
7
Channel 8
8
Channel 8
8
Channel 9
9
Channel 9
9
Channel 10
10
Channel 10
10
Channel 11
11
Channel 11
11
Channel 12
12
Channel 12
12
Table1: Channel/device togetherness with corresponding push buttons
-
5
-