background image

Calling System 

Operating Instructions (

D - 

GB)

Please read carefully!

T

hese operating instructions form an integral part of this product and contain important information on how to commission, install and 

operate it. They must be taken into consideration and given to the end user or other third party when the installer hands over the 
product. These operating instructions must be retained for future reference. 

Damage resulting from abuse or misuse is not covered by warranty. The manufacturer accepts no warranty for consequential losses 
that may result directly or indirectly from use of this equipment. Any changes or modifications not expressly approved by the party 
responsible for compliance could void the user´s authority to operate the equipment. 

The product meets the requirements of the current European and national guidelines for electromagnetic compatibility. Conformity has 
been established and the relevant statements and documents have been deposited at the manufacturer.

It should be noted that for applications that could put human life at risk, by using radio connection there is always

present a potential hazard due to extraneous disturbances.

The Operating Instructions need to be followed at all times.

Mode of Operation

Minicall12 verifies coded radio frequency signals sent by corresponding transmitters and operates display and signalisation on receipt 
of a correct signal. The Minicall-12 is not a medical device.

It must be noted that for applications or installations involving wireless transmission and which could have an influence to safety of man
or machine there may be a risk of unforeseen operation from extraneous uncontrolled radio signals. 

Description

Minicall 12 is a self observing calling system with up to 12 calling lines. For each calling line (channel) a maximum of 5 transmitters 
may be programmed. So, up to 60 transmitters (MT-12 and WT-12) may be used within this system.
Once a call is initiated at transmitters side, the Minicall12 will signalize optically and acoustically the corresponding channel and will 
transmit this call also to portable receivers (R-12). The display of portable receivers will show the channel Number (1..12). A maximum 
of 5 portable receivers may be programmed.

For the additional display of calls an optional signaler (SG-12) can be used on each channel. In addition to the function as a room 
signal light, digital outputs can also be used to control external signals.

An active call may be cancelled by pressing the corresponding push button at the Minicall12 or by confirming the call with a portable 
receiver. If more than 1 call is active, the portable receivers will show them one after the other and only the call appearing in the display
may be confirmed by pressing the push button “OK” twice.

If there is to realize a bigger range of operation, up to 5 repeaters may be used.

For any incoming call there is a potential free contact inside the housing which will switch for 1 second (up to 15 seconds selectable). 
This is for external signalisation devices if needed.

An interruption of radio communication to a transmitter is shown by flashing periodically twice the channel LED and a short BEEP. Just 
press the push button to stop signalisation if the problem is known.

Low battery of any transmitter is signalized by flashing 5 times periodically the corresponding cannel LED.

Summary of signalisation in normal operation mode:
„LED ON” is permanently on

AC-adaptor (Supply) is connected

„LED ON” flashes once a second

Minicall12 is running on battery supply (AC-adaptor missing)

„LED DATA” flashes shortly

signalizes radio communication

„LED DATA” flashes shortly twice

Batteries of Minicall12 are empty or taken off

„Channel LED” (1…12) is permanently on

call (1…12) has been received 

„Channel LED” (1…12) flashes periodically twice

radio communication to the corresponding transmitter fails

“Channel LED” (1…12) flashes 5 times periodically

battery capacity of the corresponding transmitter is low

4

 Installation and functional check

4.1 

Minicall12 

Just connect the AC-adaptor and you will hear a starting melody and the green “LED ON” will turn on. The yellow “LED DATA” flashes 
about twice a second. This will show, that the battery supply is still not activated. Keep this state until later.

4.2 

TeachIn 

(if system is ordered including CG-Service, continue at 4.4)

Transmitter 
MT-12 / WT-12

Push

button

Portable Receiver
R-12

Push

button

Repeater 
RT-12

Push

button

Signaler
SG-12

Push

button

Channel 1

1

Channel 1

1 + 2

Channel 1

7 + 8

Channel 1

1

Channel 2

2

Channel 2

2 + 3

Channel 2

8 + 9

Channel 2

2

Channel 3

3

Channel 3

3 + 4

Channel 3

9 + 10

Channel 3

3

Channel 4

4

Channel 4

4 + 5

Channel 4

10 + 11

Channel 4

4

Channel 5

5

Channel 5

5 + 6

Channel 5

11 + 12

Channel 5

5

Channel 6

6

Channel 6

6

Channel 7

7

Channel 7

7

Channel 8

8

Channel 8

8

Channel 9

9

Channel 9

9

Channel 10

10

Channel 10

10

Channel 11

11

Channel 11

11

Channel 12

12

Channel 12

12

Table1: Channel/device togetherness with corresponding push buttons

5

 -

Содержание Minicall 12

Страница 1: ...starke Reichweiteeinbu en auftreten Halten Sie bitte einen Abstand von min 1 Meter ein Bebauung jeder Art oder Vegetation beeinflussen die Reichweite Der Abstand der Antenne zum K rper wie auch zu an...

Страница 2: ...anderen Meldern Ein bereits angelernter Melder wird im Lernmode ignoriert um Zweideutigkeiten zu unterbinden Pro Kanal k nnen Sie bis zu 5 verschiedene Melder anlernen wobei die Rufe dieser 5 Melder...

Страница 3: ...r und Minicall befindet Sollte diese Ma nahme nicht ausreichen k nnen auch mehrere Repeater hintereinander eingesetzt werden Pr fen Sie die Funktion im Anschluss erneut 4 5 Einstellungen nur bei Bedar...

Страница 4: ...ur ein Schalter das angeschlossene Ger t muss also mit einer eigenen Versorgungsspannung betrieben werden Zum Anschlie en ffnen Sie das Geh use Bild 1 4 und benutzen Sie die vorgesehenen Schraubklemme...

Страница 5: ...tal outputs can also be used to control external signals An active call may be cancelled by pressing the corresponding push button at the Minicall12 or by confirming the call with a portable receiver...

Страница 6: ...ng LED flashes 5 times and an acoustic signal will confirm deletion of all learned transmitters for this channel Only all components of the corresponding channel can be deleted 4 3 2 Erase a portable...

Страница 7: ...h is only a back up supply if there is an AC supply failure The LED DATA stops flashing Please take into account that the used batteries only have a limited capacity when taking off the AC adaptor As...

Страница 8: ...adio Equipment Directive RED 2011 65 EU Restriction of Hazardous Substances RoHS und dass die nachstehenden harmonisierten europ ischen Normen zur Anwendung gelangt sind and that the following harmoni...

Отзывы: