Cool hands

 

The stove glove is supplied and equipped 
with a practical magnetic attachment. 
Always use the glove when you’re opening 
the door to put on more logs, since the fire 
do or handle may be hot. 

Don’t store the 

glove on the stove while heated. 

Don’t use 

the glove inside the stove.

 

 
 

Outdoor air connection

 

The air consumed in the combustion process has to 
be replaced, particularly in well-insulated buildings. 
The air feed to the hearth may be direct, via an 
outdoor air connection, or indirect, via a vent in an 
external wall. In the case of an outdoor air feed, the 
stove connection point has a diameter of 60 mm. If 
the air channel passes through a warm area it should 
be insulated to pre-vent condensation. The minimum 
mineral-wool insulation thickness is 30 mm, with 
plastic foil on the outside. Anti-condensation lagging 
may also be used. 

The outside air hose can be directed straight down 
through the floor or directed through the lower hole at 
the back of the stove and through the wall. See the 
picture at the top of this page. 
 

Fan (optional extras)

 

See seperate manual for fan assembly. 
 

Stone base unit (optional extras)

 

The stone-base unit,, and the cast-iron base unit, 
which are optional extras, increases the connection 
height by 40 mm.  

Receiving of goods

 

The product may have been damaged in 
transport, although this may not be 
apparent from the external packaging. It is 
important that you inspect  the stove carefully 
and report any damage to the 
transportcompany within seven days.You 
should note visible damage immediately on 
the delivery note,in connection with receipt 
of the goodson delivery, the stove is 
attached to a pallet with screws,under a 
wooden frame, and is covered with sheet 
plastic.Take precautions to avoid damage 
when unpacking and assembling the 
stove. 

The connection hose should be insulated.

 

Thestovewillbedeliveredlikethis

 

Find  the  collar  to  the  outdoor  air  supply 

inside the log compartment. 

 

A stove glove 'aka' cool hands

 

Содержание Elipse 1

Страница 1: ...e 4 Elipse 5 Elipse 6 Elipse 7 Elipse 8 ELIPSE SERIES Elipse 1 Elipse 2 Elipse 3 Elipse 4 Elipse 5 Elipse 6 Elipse 7 Elipse 8 Elipse 9 Elipse 10 Elipse Low Base Instructions for assembly and use Tisa...

Страница 2: ...afety instructions on the final page since they help you to avoid possible damage and identify potential risks Yourssincerely TISAKonstruktionHB Bear in mind that certain parts of the fireplace become...

Страница 3: ...ring structure fireplace base what is included envirinmental approval transportap attachments receipt of goods cool hands outdoor air connection fan the right location order of assembly for top connec...

Страница 4: ...m distance from a combustible wall surface is 500 mm at the sides and 100 mm at the rear see diagram at page 8 The minimum distance from furnishings in front of the stove is 1000 mm If the stove is pl...

Страница 5: ...ed The outside air hose can be directed straight down through the floor or directed through the lower hole at the back of the stove and through the wall See the picture at the top of this page Fan opt...

Страница 6: ...plished in the following order 1 Prepare air feed to the hearth if required 2 Cut hole in ceiling 3 Install the fireplace base 4 Lift the stove into position 5 Assemble the plummet stop see image belo...

Страница 7: ...nsert on top of the stove Apply stove sealant to ensure a good seal between the stove and the cover plate See pictures to the right 3 Place the door plate fireplace base in position 4 Fit the connecti...

Страница 8: ...d a cross section of 150 200 cm 2 diam 150 mm Data Output 2 8 kW Nominal output 5 0 kW Efficiency SS EN13240 upp to 78 Weights Elipse 1 105 kg Elipse 2 107 kg Elipse 3 109 kg Elipse 4 175 kg Elipse 5...

Страница 9: ...the handle towards you and then push it back again Repeat The ash falls down into the ash tray When the control is to the right the primary air feed is fully open When the control is to the left the...

Страница 10: ...se 6 Elipse 7 Elipse 8 Svea Flame on Top Svea Flame aRound 10 Elipse 1 Height 1040 mm Width 500 mm Depth 415 mm Weight 105 kg Flue collar 150 mm Logs 35 cm Elipse 2 Height 1160 mm Width 500 mm Depth 4...

Страница 11: ...0 mm Bredd 500 mm Djup 415 mm Vikt 109 kg R kr rsdiam 150 mm Vedl ngd 35 cm Elipse 4 H jd 1505 mm Bredd 500 mm Djup 415 mm Vikt 175 kg R kr rsdiam 150 mm Vedl ngd 35 cm V rmelagrande sten 60 kg 11 Eli...

Страница 12: ...Elipse 7 Elipse 8 Svea Flame in Qubic Svea Flame Step by Step 12 Elipse 5 Height 1040 mm Width 500 mm Depth 415 mm Weight 105 kg Flue collar 150 mm Logs 35 cm Elipse 6 Height 1160 mm Width 500 mm Dep...

Страница 13: ...se 5 Elipse 6 Elipse 7 Elipse 8 Elipse 8 Height 1505 mm Width 500 mm Depth 415 mm Weight 175 kg Flue collar 150 mm Logs 35 cm Heat stone 60 kg Elipse 7 Height 1290 mm Width 500 mm Depth 415 mm Weight...

Страница 14: ...se 10 Elipse Low Base 14 Elipse 9 Height 1635 mm Width 500 mm Depth 415 mm Weight 177 kg Flue collar 150 mm Logs 35 cm Elipse 10 Height 1635 mm Width 500 mm Depth 415 mm Weight 177 kg Flue collar 150...

Страница 15: ...Elipse 1 Elipse 2 Elipse 3 Elipse 4 Elipse 5 Elipse 6 Elipse 7 Elipse 8 15 Elipse Low Base Height 790 mm Width 500 mm Depth 415 mm Weight 85 kg Flue collar 150 mm Logs 35 mm...

Страница 16: ...got going it may be necessary to reduce the heat Reduce the combustion rate using the air feed control see page 9 Output control Thevolumeofcombustionairandtheheatoutputdep endonthetypeofwoodused the...

Отзывы: