Svantek SV100A Скачать руководство пользователя страница 2

The SV 100A measures the A(8) vibration exposure and the overall vibration total 
value (VECTOR) in accordance with ISO 2631-1 and EU Directive 2002/44/EC. 
The A(8) result is given in m/s

(RMS), m/s

1.75

 (VDV) and points. The SV 100A 

monitors the time left to limits and activates the alarm when the limits are 
reached.  
The force sensors in the SV 100A automatically detect the presence of a user 
or vehicle driver which enables real daily exposure calculations for the period of 
time when the user is in contact with the vibrating surface.

ISO 2631-1 and EU Directive 2002/44/EC 

List of Contents

Page   3 

 CONTENTS OF THE SV 100A BOX 

Page   4 

 SETUP IN SUPERVISOR SOFTWARE

Page   5 

 IN-SITU CHECK

Page   6 

 RUNNING THE MEASUREMENT WITH ASSISTANT APPLICATION

Page   7 

 DATA DOWNLOAD AND REPORTING

Page   8 

 SUPPORT AND SERVICE

Page   9 

 TECHNICAL SPECIFICATION

2

SV 100A User Guide

Содержание SV100A

Страница 1: ...SV100A Vibration Dosimeter User Guide...

Страница 2: ...s in the SV 100A automatically detect the presence of a user or vehicle driver which enables real daily exposure calculations for the period of time when the user is in contact with the vibrating surf...

Страница 3: ...lysis Veri cation of vibration sources Research and development SF 100A 3OCT 1 1 1 3 octave analysis Veri cation of vibration sources Research and development SF 100A WAV Time domain signal recording...

Страница 4: ...settings using panels on the right hand side 8 Disconnect the USB cable Instrument is ready to measure SV 100A User Guide 4 2 Connect the USB cable to PC Make sure the Supervisor software and USB dri...

Страница 5: ...100A on the SA111 x axis vertical Set up of SV 111 5 Start the calibrator using level of 1 m s2 at 16 Hz and wait until all 3 LEDs are green SV 100A User Guide 5 4 Enable Calibration menu in SV 100A b...

Страница 6: ...ndroid smarphone 3 Start the application The Assistant will ask you to enable Bluetooth and Localization services on your smartphone tablet 4 The Assistant will detect the SV100A automatically Install...

Страница 7: ...open file simply double click on it SV 100A User Guide 7 2 Select files you wish to download and click the Download button located in the bottom section 3 Once the file is downloaded it will be automa...

Страница 8: ...s website Service Office 48 22 51 88 320 or 48 22 51 88 322 Office hours are 9 00 a m to 5 00 p m Central European Time E mail at office svantek com Internet at www svantek com Address SVANTEK Sp z o...

Страница 9: ...nding Band Limiting filters Wf for motion sickness filter measurements according to ISO 2631 1 option RMS RMQ Detectors Digital true RMS RMQ detectors with Peak detection resolution 0 1 dB Measurement...

Отзывы: