background image

SV 307 User Guide

6

The SV 307 is delivered with a 

waterproof power supply

. If it happens that AC 

mains powering is not available, the 

internal battery

 can power the SV 307 for 

up to 6 days. The battery life can be extended with a simple cable connection of a 

solar panel or external battery

 to DC-IN socket in SV 307.

Powering

Use of Solar Panel

Optionally the SB 371 solar panel (40 W) can be used to extend the autonomy of 
SV 307. The SB 371 is simply connected to DC-IN socket in SV 307 with a SC 333 
cable. The efficiency of charging the internal battery from solar panel depends 
on the amount of sunlight available locally. In cloudy conditions (e.g. in Poland) 
a minimum of 130 W solar panel is needed to supply enough power to ensure 
continuous operation of SV 307. 

Use of External Battery

Optionally the SB 275 external battery (33 Ah) can be used to extend the autono-
my of SV 307. The SB 275 is simply connected to DC-IN socket in SV 307. 
The SB 272 should be recharged with its included dedicated charger unit

Calibration

In accordance with ISO 1996-2, imme-
diately before and after each series of 
measurements, a class 1 sound calibrator 
in accordance with IEC 60942:2003 shall 
be applied to the microphone to check 
the calibration of the entire measuring 
system at one or more frequencies.
To properly calibrate the SV 307 with a 
separate acoustic calibrator go to the 
main menu then Calibrate by Measure-
ment.
It is necessary to carefully remove the up-
per straight tube with the anti-bird spikes 
to apply the calibrator cavity directly over 
the microphone of the SV 307.
Be careful not to remove the locking 
sleeve for the microphone itself when 
calibrating.

Содержание SV 307

Страница 1: ...is capable of logging sum mary results SR and spectral data with interval steps down to 1 second Also time history results TH down to 100 milliseconds Summary results SR include LEQ PEAK MAX MIN with...

Страница 2: ...d under the bottom cover of the SV 307 The bottom cover operates as a gasket therefore it is neces sary to carefully unscrew the 4 screws to remove it It is strongly recommended to configure the remot...

Страница 3: ...n Access Point Name SvanNET Application SvanNET Application is a simple software user interface used for the configura tion of the SV 307 to connect with the SvanNET service To obtain the application...

Страница 4: ...alarm email The configuration of Status alarms ins available in the Status tab in SvanNET Projects SvanNET Projects is an optional payable extension to the basic service offering fully automated mana...

Страница 5: ...SC is located in the top of the tube direct ly above the microphone of the SV 307 System Check The ASC is based on a small speaker and the three MEMS microphones in the SV 307 Activation of the ASC en...

Страница 6: ...ure continuous operation of SV 307 Use of External Battery Optionally the SB 275 external battery 33 Ah can be used to extend the autono my of SV 307 The SB 275 is simply connected to DC IN socket in...

Страница 7: ...service office at the following number or contact via the SVANTEK s website Service Office 48 22 51 88 320 or 48 22 51 88 322 Office hours are 9 00 a m to 5 00 p m Central European Time E mail at offi...

Отзывы: