NO
YES
OR
NO
YES
-25-
The temperature readout is abnormal.
Remove the J8 connector in Main
PCB for Hull Unit portion and
check the resistance at No.1 and
No.2.
※Alignment for soundome cable connectors.
Soundome Check by using a tester
Is the correct resistance rate
found to be normal?
SOUNDOME
MAIN PCB in HULL UNIT Portion
Remove the J8 connector in Main
PCB for Hull Unit portion.
Connect the 5k ohm resistance
between the terminal No.1 and No.
2.
Is approx. 25℃. displayed?
SOUNDOME
MAIN PCB in HULL UNIT Portion