Troubleshooting
SDS-35
33
5004522-000 Rev. 03
SUZOHAPP
Number of
flashes of the
red status light
Description
Action
1
Cash box is removed from
banknote validator.
Check if cash box is installed correctly.
2
Sense-a-click error.
Please, contact a service technician for
support.
3
Cash box is full.
Replace cash box or take out banknotes
from cash box.
4
Jam in cash box or stacker motor
fault.
1 Check for jammed banknotes in
cash box.
2 Check operation of stack motor.
5
Failure of dielectric sensors.
Please, contact a service technician for
support.
6
Failure of optical sensors.
Please, contact a service technician for
support.
7
Failure of inductive sensors.
Please, contact a service technician for
support.
8
Failure of transporting motor.
1. Ensure no banknotes are stuck in the
banknote path.
2. Power the validator off and on.
9
Speed of transport motor is fast. Ensure power supply voltage is within
limits.
10
Failure alignment mechanism
1. Ensure no banknotes are stuck in the
banknote path.
2. Power the validator off and on and
check if alignment mechanise is auto-
matically corrected.
11
Banknote pathway is not clear.
Ensure no banknote fragments are in
the banknote path.
12
Banknote jam in the entry slot of
cash box. Credit not issued.
Check for banknote jam in the cash
box.
13
Overload of transport motor.
1. Ensure no banknotes are stuck in the
banknote path.
2. Power the validator off and on.