NICE3000 User Manual Function parameter description
129
The lift will return to the landing when the system is in fire landing state.
F6-04
Stop landing
Default
1
Min. Unit
1
Setting Range
The lowest landing(F6-01)
~
The highest landing(F6-00)
When lift is in stopping state, it will return to this landing after completing control box command.
Function code
Name
Default
Min. Unit
Setting Range
F6-05
service floor 1
65535
1
0
~
65535
F6-06
service floor 2
65535
1
0
~
65535
F6-05 set what kind of floors command lift respond in floors 1~16. F6-06 set what kind of floors
command lift respond in floors 17~31.
The setting way of F6-05 service floor 1:
The floor service is controlled by binary system number of 16 bit. The binary system number
express the floor 1~16 from low bit to high bit, The setting relevant bit 1express that lift
responds to this floor
’
s calling, and the setting relevant bit 0 express that lift doesn
’
t respond
to this floor
’
s calling. For example, floors in need of service are listed as follows:
Binary
digit
Relevant
floor
Service
or not
Binary bit
setting
Binary
digit
Relevant
floor
Service
or not
Binary bit
setting
Bit0
Floor 1
ON
1
Bit8
Floor 9
OFF
0
Bit1
Floor 2
OFF
0
Bit9
Floor 10
ON
1
Bit2
Floor 3
ON
1
Bit10
Floor 11
ON
1
Bit3
Floor 4
ON
1
Bit11
Floor 12
OFF
0
Bit4
Floor 5
ON
1
Bit12
Floor 13
ON
1
Bit5
Floor 6
ON
1
Bit13
Floor 14
ON
1
Bit6
Floor 7
ON
1
Bit14
Floor 15
ON
1
Bit7
Floor 8
OFF
0
Bit15
Floor 16
ON
1
The relevant binary digit setting is added in the list. The binary bit is 1111011001111101,and the
relevant algorism number is 63101,so F6-05 should be set as 63101.
The setting way of F6-06 is the same with F6-05.
F6-07
Group control number
Default
1
Min. Unit
1
Setting Range
1
~
8
It can be used to choose lift number of group control:
1
:
Single lift running
2
:
2 parallel lift running
3~8: Group control running (need the cooperation of group control panel MCTC-GCB-A)
Содержание MCTC-CTB-A
Страница 12: ...Preface NICE3000 User Manual 12...
Страница 15: ...Safety information and attention items 1...
Страница 21: ...Product information 2...
Страница 29: ...3 Structure of the control system and the component introduction...
Страница 69: ...4 Installation and wiring...
Страница 80: ...Installation and wiring NICE3000 User Manual 80...
Страница 81: ...5 Function parameters tables...
Страница 100: ...Function parameters tables NICE3000 User Manual 100...
Страница 101: ...6 Function parameter description...
Страница 153: ...7 System typical application and adjustment...
Страница 172: ...System typical application and adjustment NICE3000 User Manual 172...
Страница 173: ...8 Fault diagnosis and countermeasures...