ELECTRIC BICYCLE METER KT—LCD5 Product User Manual
- 26 -
C5 parameter setting interface
C5 is controller maximum operating current adjustment setting (tiny-adjustment of
limit current value), the default value is 10, setting range is 0-10, hold
button (
UP
)
or
button
(DOWN)
shortly for selection.
C5 parameter definition table
:
C5 value
Maximum current value(A)
00
Three level slow start/ Maximum current value
01
Two level slow start/ Maximum current value
02
One level slow start/ Maximum current value
03
Maximum current value
÷
2.00
04
Maximum current value
÷
1.50
05
Maximum current value
÷
1.33
06
Maximum current value
÷
1.25
07
Maximum current value
÷
1.20
08
Maximum current value
÷
1.15
09
Maximum current value
÷
1.10
10
Maximum current value
When C5 setting is 10, maximum current value is controller maximum operating
current value (ie, limit current value); when setting is 9, maximum current value divided by
1.10, when setting is 8, maximum current value divided by 1.15 and so on.
After finishing C5 parameter setting, hold
button
(SW)
shortly to save the
current set values and enter C6 parameter setting interface.
○
C6 Backlight Brightness Adjustment Setting
Enter C6 parameter setting interface after C5 parameter setting is finished, C6
parameter column flashes.