background image

USE LIMITATIONS:

 

1. Do 

NOT

 use the respirator or enter or stay in a contaminated area under the following circumstances: 

• Atmosphere contains less than 19.5% oxygen 
• Atmosphere contains oil aerosols if using N protection class respirator

 

• For protection against gases or vapors 
• Contaminants or their concentrations are unknown or immediately dangerous to life or health 
• Concentrations or contaminants exceed maximum use concentrations in applicable OSHA standards 

or applicable government regulations or 10 times the PEL (Permissible Exposure Limit), whichever 
is lower 

• For sandblasting, paint-spray operations, asbestos

 

2. Do 

NOT

 modify or misuse the respirator. 

3. Do 

NOT 

use the respirator with beards or other facial hair that interferes with direct contact between 

the face and the edge of the respirator, or any other conditions that may prevent a good face-seal. 

 
WARNING:

 

This  respirator  helps  protect  against  certain  contaminants.  It  may  not  eliminate  the  risk  of  contracting 
disease or infection. 

Misuse may result in sickness or death. 

Materials  which  may  come  into  contact  with  the  wearer’s  skin  could  cause  allergic  reactions  to 
susceptible individuals. 

 
FOR MORE INFORMATION

 

or assistance please contact with Manufacturer.

 

 

 

FITTING INSTRUCTIONS

 

Follow these instructions each time respirator is worn. 
1. Hold the respirator in one hand with the nosepiece at your fingertips, allowing the headbands to hang 

below your hand. 

2. Press the respirator against your face with the nosepiece on the bridge of your nose. 
3. Place the top band high on the back of your head. Move the bottom band over your head and position 

it below your ears. 

4. Using both hands, mould the nosepiece to the shape of your nose. 
5. Test the fit. Cup both hands over the respirator and exhale vigorously. If air flows around your nose, 

tighten the nosepiece. If air leaks around the edges, reposition the bands for better fit. 

6. Fit-check the face-seal as follows:   

• Place both hands over the respirator without disturbing its position. 
• If the respirator is not fitted with an exhalation valve, exhale sharply. 
• If the respirator is fitted with an exhalation valve, inhale sharply (a negative pressure should be felt 

inside the respirator). 

• If you detect air-leaks, readjust the head straps and/or the position. 

WARNING:

  If  you  cannot  achieve  satisfactory  fit,  do  NOT  enter  the  contaminated  area.  See  your 

Supervisor.

 

 

USE INSTRUCTIONS: 

1. Failure to follow all instructions and limitations concerning the use of the respirator and/or failure to 

wear  the  respirator  for  the  whole  duration  of  exposure  to  contaminants  can  seriously  reduce  the 
performance characteristics of the respirator and lead to illness, injury or death. 

2.  Before  use,  the  wearer  must  first  be  trained  by  the  employer  in  the  correct  use  of  the  respirator  in 

accordance with applicable safety and health standards. 

3. OSHA standards including 29 CFR 1910.134(e) (5) and CSA standard Z94.4-93 require that the 
wearer  be  fit-tested.  Before  occupational  use  of  this  respirator  a  written  respiratory  protection 
program must be implemented meeting all the local government requirements. In the United States 
employers must comply with OSHA 29 CFR 1910.134 which includes medical evaluation, training, 
and fit testing. 

4. Discard the respirator and replace with a new one if: 

• Excessive clogging of the respirator causes breathing difficulty. 
• The respirator becomes damaged.   

5. Leave the contaminated area if dizziness, irritation or other distress occurs. 
 
 