Interfaces of the Device
4-2
4.2
Shielding D-SUB Connectors
You must shield D-SUB connectors as follows:
Figure 4-2
Shielding D-SUB connectors
1
D-SUB connector
2
Shield
3
Cable clip
4
Cable
The shield must be folded back into a flat position over the cable sheath.
When fastening the cable with the cable clip, as much of the shielding as possible
must be in contact with the housing and sufficient strain relieve must be ensured.
4
nc
Not Connected
5
GND
Ground
6
GND
Ground
7
GND
Ground
8
GND
Ground
9
VGA 5V
VCC, Fused
10
GND
Ground
11
nc
Not Connected
12
VGA SDA
DDC Data
13
CRTHS
Analog HSYNC
14
CRTVS
Analog VSYNC
15
VGA SCL
DDC Clock
Table 4-2
Pin assignment - VGA
Pin
Designation
Function