background image

 
 

Sutron

 

Corporation

 

SDI

TB

 

Users

 

Manual

  

 

 

Rev.

 

1.1

   

 

  

5/24/2018

 

         

pg.

 

12

 

 

 

 

Command

 

Name

 

Command

 

Response

 

Notes

 

XBKTSZ

 

Read/Write

 

tipping

 

bucket

 

size

 

aXBKTSZ!

 

or

   

<bucket

 

size>!

 

 

Ex:

 

0XBKTSZ!

 

or

 

0.01!

 

 

Set

 

the

 

bucket

 

size

 

to

 

compute

 

0.01

 

inches

 

of

 

rainfall

 

for

 

every

 

tip.

 

a+<bucket

 

size>

 

 

where:

 

<bucket

 

size>

 

=

 

Bucket

 

size

 

 

Ex:

 

0+0.01

 

Command

 

to

 

configure

 

the

 

bucket

 

size.

 

The

 

bucket

 

size

 

is

 

used

 

to

 

convert

 

bucket

 

tips

 

into

 

rainfall.

 

If

 

the

 

compensation

 

coefficients

 

(

XCOMP

)

 

are

 

not

 

provided,

 

then

 

each

 

tip

 

is

 

equal

 

to

 

bucket

 

size.

If

 

coefficients

 

are

 

provided,

 

then

 

a

 

3

rd

 

order

 

polynomial

 

is

 

used

 

to

 

convert

 

tips

 

into

 

rainfall.

 

Default

 

value

 

=

 

0.01

 

XEDGE

  

Read/Write

 

edge

 

aXEDGE!

 

or

   

<edge>!

 

Where

 

<edge>

  

=

 

1

 

(rising

 

edge)

 

=

 

0

 

(falling

 

edge)

 

 

Ex:

 

0XEDGE!

 

or

 

1!

 

 

Configures

 

the

 

Tipping

 

Bucket

 

input

 

to

 

register

 

a

 

tip

 

on

 

the

 

rising

 

edge.

 

a+<edge>

 

 

where:

 

<edge>

 

=

 

new

 

edge

 

Ex:

 

0+1

 

Command

 

to

 

configure

 

the

 

tipping

 

bucket

 

input

 

edge.

 

If

 

a

 

falling

 

edge

 

is

 

configured

 

then

 

the

 

internal

 

pull

 

up

 

resistor

 

is

 

automatically

 

active,

 

else

 

pull

down

 

resistor

 

is

 

activated.

 

 

Default

 

value

 

=

 

0

 

(pull

up)

 

Содержание 8800-1205

Страница 1: ...SDI TB SDI 12 Tipping Bucket Interface with Smart Compensation Operations Maintenance Manual Part No 8800 1205 Revision 1 1 25 May 2018...

Страница 2: ...Quick Start 3 2 1 Unpacking 3 2 2 Operation 4 2 3 Connections 7 2 4 Sensor Configuration 7 3 Command Reference 8 3 1 Standard SDI 12 commands 8 3 2 Extended SDI 12 commands 11 Appendix A Specificatio...

Страница 3: ...et The SDI TB sensor has a backup power source that permits un interrupted operation for up to 10 hours in case SDI 12 power is lost 2 Quick Start 2 1 Unpacking Remove SDI TB sensor from the shipping...

Страница 4: ...ly has been configured A user programmable debouncing duration can be configured to filter out noise during the voltage transitions as the switch makes breaks contact The SDI TB uses a configurable Bu...

Страница 5: ...et size is used The SDI TB has an internal Real Time Clock RTC that is used to keep time and can be programmed to perform daily and annual rainfall resets The SDI TB has a built in rechargeable backup...

Страница 6: ...c_last raw_ tip_year acc_year acc_daily acc_yest acc_last total accumulations since the last M command was issued Every time an M command is issued this parameter will be reset raw_ tip_year The SDI T...

Страница 7: ...the address if needed The SDI TB has a default debouncing of 15ms If the bucket has a switch close time other than 15ms the appropriate debounce duration can be set using the XDBNC command If the tip...

Страница 8: ...se Notes Query SDI Address A where a address Only one SDI 12 device should be connected to the bus since all will respond Acknowledge Active a A I Send Identification aI For a master the expected resp...

Страница 9: ...mulation this year acc_daily Total accumulation today acc_yest Total accumulation Yesterday Ex 0 0 01 12 0 12 0 03 0 02 Returns the current accumulation values and resets the accumulated rainfall sinc...

Страница 10: ...Sutron Corporation SDI TB Users Manual Rev 1 1 5 24 2018 pg 10...

Страница 11: ...the XDT command is issued without any arguments eg aXDT the current time is returned without modifying the existing time Default 2012 01 01 00 00 0 hrs XDR Read Write daily rainfall reset time aXDR or...

Страница 12: ...he compensation coefficients XCOMP are not provided then each tip is equal to bucket size If coefficients are provided then a 3rd order polynomial is used to convert tips into rainfall Default value 0...

Страница 13: ...milliseconds This is used to filter out noisy tipping bucket outputs so that the switching noise is not counted as a tip The TB IN input must be held in the active state for atleast debounce_duration...

Страница 14: ...e SDI TB implements a 3rd order polynomial to compensate for heavy rainfall rates If no coefficients are provided each tip bucket_size The polynomial is of the form Where inches of rain per hour XYA R...

Страница 15: ...tor 5 pin screw less connector POWER Input Voltage DC 4v 20v Initial capacitor discharged Power up delay 2 minutes Internal backup power run time 10 hours Internal backup power charge time 18 hours In...

Страница 16: ...estion on an interface we will work with you until we find a solution Sometimes a problem is application related Although we pride ourselves on handling 95 of application related questions over the ph...

Страница 17: ...Sutron Corporation SDI TB Users Manual Rev 1 1 5 24 2018 pg 17...

Страница 18: ...itions Sutron requires the return of the defective electronic products or parts to the factory to establish claim under this Warranty The customer shall pre pay transportation charges to the factory S...

Отзывы: