Operation
SUSPA ELS3 HeavyDuty - Installation Instruction
Page 61
Childproof lock is active
Childproof lock is activated by holding the "M" key for 10s.
Indicator: Drive commands are acknowledged with dual tone and not implemented, error code
A65 in manual switch display.
Solution: Childproof lock is deactivated by holding the "M" key for 10s.
Drive monitoring
Difference between the synchronously controlled drives is too large.
Indicator: Drive commands are not implemented, error code A6F in manual switch with display
(LCD).
Solution: Check connection of the lifting elements and verify and ensure their correct function.
Then perform reset.
Connection error
Manual switches, motors or power plugs are not correctly connected to the controller.
Indicator: Diverse symptoms
Solution: Check the correct connection of the components, make sure that all connectors are firmly
plugged into the corresponding sockets!
7.6.2
Troubleshooting
This section contains remedial measures in case of malfunctions. If an error or fault occurs that is
not listed in this table, please contact your supplier.
The listing below handles problems that are caused directly in connection with the controller.
CAUTION
The troubleshooting and fault rectification should be done only by a specialist
who has completed his professional education as an electro-mechanical installation engineer or an
equivalent qualification. Make note of the user groups in section 2.5.3.
IMPORTANT
Pay attention to the initialization (reset movement) in section 7.5.