www.surveon.com
44
Surveon CAM5130
DI & DO
Digital Input (DI) and Digital Output (DO) stand are used for event triggering.
The camera has 1 DO and 1 DI ports. Settings for these ports can be found
under
Event Notification> DI & DO
. Conditions for DI and DO triggering, as
well as notifications for can be set under
Event Settings
.
Digital Input
The input is listed as Input1 and connected to external circuits such as
window break detectors. These inputs can be tested by clicking the
Test
button in the input entry.
Each input has a
Normal Status
:
•
Normal Open
– the DI requires a low voltage input, with the
following configuration.
It is triggered when it does not receive this input.
•
Normal Close
– the DI requires a high voltage input (+12V), with the
following configuration.
It is triggered when it does not receive this input.
•
Off
- DI inputs are closed at all times. The camera will not respond
to any signals on this DI.