32
E N G L I S H
Accuracy: (a% r b digits), guarantee for 1 year.
Operating temperature: 23°C + 5°C
Relative humidity: 75%R.H
Temperature coefficient: 0.1x (specified accuracy) /1°C
Remark: Input impedance: 10M
Ω
//<100pF” Displays effective value of sine wave
(mean value response). Frequency response: 40Hz~1kHz. To adjust reading in
accordance with effective value
AC Voltage: Auto ranging
A.
Range
Resolution
2 V
20 V
200 V
600 V
1 mV
10 mV
100 mV
1 V
Accuracy
± (1.2%+5)
± (1.5%+5)
Overload Protection
600 V rms
Remark: Input impedance: 10M
Ω
DC Voltage: Auto ranging
B.
Range
Resolution
200 mV
2 V
20 V
200 V
600 V
0.1 mV
1 mV
10 mV
100 mV
1 V
Accuracy
± (0.8%+3)
± (0.8%+1)
± (1%+3)
Overload Protection
600 V rms
ACCURACY SPECIFICATIONS
Remark: Input impedance: 10M
Ω
Resistance: Auto ranging
C.
Range
Resolution
200
Ω
2 k
Ω
20 k
Ω
200 k
Ω
2 M
Ω
20 M
Ω
100 m
Ω
1
Ω
10
Ω
100
Ω
1 k
Ω
10 k
Ω
Accuracy
± (1%+2)
± (1.2%+2)
± (1.2%+2)
± (1.5%+2)
Overload Protection
600 V p
Remark:
Open circuit voltage approximate 0.45 V The buzzer may or may not beeps when
the resistance of a circuit under test is between 50
Ω
and 120
Ω
The buzzer may
not beep when the resistance of a circuit under test is greater than 120
Ω
Continuity Test
D.
Range
Resolution
100 m
Ω
Accuracy
Around
≤
50
Ω
the
buzzer beeps
Overload Protection
600 V p